Qiang Hao

Qiang Hao

Auto-generated profile, based on publicly available information

Qiang Hao

Key Laboratory of Time Reference and Applications, NTSC, Chinese Academy of Science, Xi’an, China

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2016 in Review of Scientific Instruments
Verified
Journal Article
Closed access
QHQiang Hao
Qiang Hao
WLWenbing Li
Wenbing Li
SHShengguo He
Shengguo He
JLJianfeng Lv
Jianfeng Lv
PWPengfei Wang
Pengfei Wang
GMGanghua Mei
Ganghua Mei
In this article, a new type of physics package with high signal to noise ratio for a rubidium atomic frequency standard is reported. To enhance the clock transition signal, a slotted tube microwave cavity with a field orientation factor of 0.93 and an absorption cell with the diameter of 30 mm were utilized in design of the cavity-cell assembly. Based on the spectral analysis of the three commonly used rubidium spectral lamps, the spectral lamp filled with Xe gas was chosen as the optical pumping source for its small line shape distortion. To suppress the shot noise of the signal, a band pass interference filter was used to filter out Xe spectral lines from the pumping light. A desk system of the rubidium frequency standard with the physics package was realized, and the short-term stability of the system was predicted and tested. The measured result is 2.4 × 10−13 τ−1/2 up to 100 s averaging time, in good agreement with the predicted one.

1 February 2024 in Physical Review Applied
Verified
Journal Article
Closed access
PDF file
QHQiang Hao
Qiang Hao
SYShaojie Yang
Shaojie Yang
JRJun Ruan
Jun Ruan
PYPeter Yun
Peter Yun
SZShougang Zhang
Shougang Zhang
Pulsed optically pumped (POP) Rb atomic clock is considered to be a powerful technique for the Rb atomic clock due to the capability of light-shift mitigation and atomic spectroscopy narrowing. Relevant investigations are conducted over two decades, however, no integrated prototype of such a kind of clock has been reported yet. Here, we present an integrated prototype of the POP Rb atomic clock and quantitatively characterize its physical properties. The atomic clock shows a short-term fractional frequency stability of 2.6×10−13/τ (where τ is the averaging time), and comes to 2.3×10−15 with 40 000 s averaging (drift removed) under atmospheric conditions. Physical effects contributing to the long-term frequency stability are carefully analyzed and cavity-pulling shift is identified as the leading limit. The techniques presented here enable realizing a low 10−15 level vapor-cell atomic clock under atmospheric conditions, which could benefit a wide range of terrestrial applications, such as quantum communication, decimeter-level terrestrial positioning.

25 November 2019 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
QHQiang Hao
Qiang Hao
WXWenxiang Xue
Wenxiang Xue
WLWenbing Li
Wenbing Li
FXFeng Xu
Feng Xu
XWXin Wang
Xin Wang
SZShougang Zhang
Shougang Zhang
We report a high-performance pulsed optically pumped (POP) Rb clock based on a novel magnetron-type microwave cavity. The cavity has a volume of 30 mL, enabling a highly homogenous microwave field distribution. With the laser frequency tuning to the ground-state hyperfine level F=2 of D2 line, we observe a Ramsey fringe contrast of 52% in terms of optical absorption detection. The resultant shot noise limit is estimated to be 1.6 × 10 -14 τ -1/2. The clock frequency stability is measured as 2.3 × 10 -13 τ -1/2(1.100s), which is limited by the relative intensity noise of the light.

25 May 2020 in Satellite Navigation
Verified
Journal Article
Open access
PDF file
QHQiang Hao
Qiang Hao
WXWenxiang Xue
Wenxiang Xue
FXFeng Xu
Feng Xu
KWKemu Wang
Kemu Wang
PYPeter Yun
Peter Yun
SZShougang Zhang
Shougang Zhang
Strong environmental dependence is an intractable problem for vapor cell clocks, for which the high-temperature sensitivity of the physics package is considered one of the dominant reasons. In this paper, we report the design and realization of a low-temperature-sensitive physics package for vapor cell clocks. The physics package comprises three layers of magnetic shields, three layers of heating ovens, and the cavity-cell assembly. The cavity-cell assembly employs a compact magnetron-type cavity and a Rb vapor cell sealed with N2-Ar mixed buffer gas. The dependence of the clock frequency on temperature fluctuation is evaluated to be 2 × 10−11/°C. In pursuit of the stable temperature, a three-stage temperature regulator is implemented on the physics package. It adopts a combination of open and closed-loop control to address the problem of significant thermal coupling between the heating ovens. Under a laboratory environment, the measured Hadamard deviation of the temperature variation is 4 × 10−5 °C in 1 day of averaging.

1 July 2019 in Chinese Physics Letters
Verified
Journal Article
Closed access
WLWen-Bing Li
Wen-Bing Li
QHQiang Hao
Qiang Hao
YDYuan-Bo Du
Yuan-Bo Du
SHShao-Qing Huang
Shao-Qing Huang
PYPeter Yun
Peter Yun
ZLZe-Huang Lu
Ze-Huang Lu
We demonstrate a simple scheme of 6.835 GHz microwave source based on the sub-sampling phase lock loop (PLL). A dielectric resonant oscillator of 6.8 GHz is directly phase locked to an ultra-low phase noise 100 MHz oven controlled crystal oscillator (OCXO) utilizing the sub-sampling PLL. Then the 6.8 GHz is mixed with 35 MHz from an direct digital synthesizer (DDS) which is also referenced to the 100 MHZ OCXO to generate the final 6.835 GHz signal. Benefiting from the sub-sampling PLL, the processes of frequency multiplication, which are usually necessary in the development of a microwave source, are greatly simplified. The architecture of the microwave source is pretty simple. Correspondingly, its power consumption and cost are low. The absolute phase noises of the 6.835 GHz output signal are −47 dBc/Hz, −77 dBc/Hz, −104 dBc/Hz and −121 dBc/Hz at 1 Hz, 10 Hz, 100 Hz and 1 kHz offset frequencies, respectively. The frequency stability limited by the phase noise through the Dick effect is theoretically estimated to be better than 5.0 × 10−14τ1/2 when it is used as the local oscillator of the Rb atomic clocks. This low phase noise microwave source can also be used in other experiments of precision measurement physics.

2 April 2015
Verified
Book Chapter
Closed access
PDF file
QHQiang Hao
Qiang Hao
SHShengguo He
Shengguo He
FXFeng Xu
Feng Xu
FZFeng Zhao
Feng Zhao
GMGanghua Mei
Ganghua Mei