1 September 2017 in Review of Scientific Instruments
A high-frequency signal generator based on direct digital synthesizer (DDS) and field-programmable gate array (FPGA) is presented. The FPGA provides the controlling time sequence for the DDS, which has a highest output frequency of 1.4 GHz and a frequency resolution of 190 pHz. At an output frequency of 1.2 GHz, the measured phase noise, including the contribution of the reference clock, is −65 dBc/Hz@1 Hz, while the intrinsic phase noise is −82 dBc/Hz@1 Hz. Time delay of the DDS is measured to be less than 150 ns. The signal generator is used to drive an acousto-optic modulator, and the rise time due to the whole link is 24 ns. The developed signal generator can be used in many precision measurement experiments in the fields of atomic, molecular, and optical physics.
1 April 2022 in New Journal of Physics
FSFerdinand Schmidt-Kaler
We implement three-dimensional polarization gradient cooling (PGC) of trapped ions. Counter-propagating laser beams near 393 nm impinge in lin ⊥ lin configuration, at a frequency below the S1/2 to P3/2 resonance in 40Ca+. Our measurements demonstrate that cooling with laser beams detuned to lower frequencies from the resonance is robust against an elevated phonon occupation number and works continuously in the crossover from regular Doppler cooling to detunings of tens of linewidths. It is thus robust against heating events and also works well for an initial ion motion far out of the Lamb–Dicke regime. We show that PGC performance strongly depends on residual micromotion (MM) and find PGC working for a MM modulation index β ⩽ 0.1. Still, we find that the spectral impurity of the laser field affects both, cooling rates and cooling limits. Thus, a Fabry–Pérot cavity filter is employed to efficiently suppress amplified spontaneous emission of the diode laser. We demonstrate mean phonon numbers for a single ion of 5.4(4) at a trap frequency of 2π × 285 kHz and 3.3(4) at 2π × 480 kHz, in the axial and radial directions, respectively.
10 February 2020 in Hyperfine Interactions
Ions of the isomer 229mTh are a topic of high interest for the construction of a “nuclear clock” and in the field of fundamental physics for testing symmetries of nature. They can be efficiently captured in Paul traps which are ideal for performing high precision quantum logic spectroscopy. Trapping and identification of long-lived 232Th+ ions from a laser ablation source was already demonstrated by the TACTICa collaboration on Trapping And Cooling of Thorium Ions with Calcium. The 229mTh is most easily accessible as α-decay daughter of the decay of 233U. We report on the development of a source for slow Th ions, including 229mTh for the TACTICa experiment. The 229mTh source is currently under construction and comprises a 233U monolayer, from which 229mTh ions recoil. These are decelerated in an electric field. Conservation of the full initial charge state distribution of the 229mTh recoil ions is one of the unique features of this source. We present ion-flight simulations for our adopted layout and give a final source design. This source will provide Th ions in their original charge state at energies suitable for capture in a linear Paul trap for spectroscopy investigations.
1 July 2019 in Chinese Physics Letters
We demonstrate a simple scheme of 6.835 GHz microwave source based on the sub-sampling phase lock loop (PLL). A dielectric resonant oscillator of 6.8 GHz is directly phase locked to an ultra-low phase noise 100 MHz oven controlled crystal oscillator (OCXO) utilizing the sub-sampling PLL. Then the 6.8 GHz is mixed with 35 MHz from an direct digital synthesizer (DDS) which is also referenced to the 100 MHZ OCXO to generate the final 6.835 GHz signal. Benefiting from the sub-sampling PLL, the processes of frequency multiplication, which are usually necessary in the development of a microwave source, are greatly simplified. The architecture of the microwave source is pretty simple. Correspondingly, its power consumption and cost are low. The absolute phase noises of the 6.835 GHz output signal are −47 dBc/Hz, −77 dBc/Hz, −104 dBc/Hz and −121 dBc/Hz at 1 Hz, 10 Hz, 100 Hz and 1 kHz offset frequencies, respectively. The frequency stability limited by the phase noise through the Dick effect is theoretically estimated to be better than 5.0 × 10−14τ1/2 when it is used as the local oscillator of the Rb atomic clocks. This low phase noise microwave source can also be used in other experiments of precision measurement physics.
1 September 2018 in AIP Advances
The Dick effect is one of the main factors limiting the short-term frequency stability of Cs fountain clocks, which is especially decided by the phase noise of the local oscillator at smaller offset frequency. Here we report on the development of a 9.192 GHz microwave frequency synthesizer with low phase noise to be used as the local oscillator for Cs fountain clocks. The synthesizer is based on frequency multiplication and synthesis from an ultra-low phase noise 5 MHz Oven Controlled Crystal Oscillator (OCXO). The key component of the frequency multiplication is a non-linear transmission-line (NLTL) as a frequency comb generator. Based on the principle of the NLTL, we carefully optimized the input power, the input and output impedances of the NLTL to suppress its excess phase noise. The measured results show that the absolute phase noises of 9.192 GHz signal are -64 dBc/Hz, -83 dBc/Hz, -92 dBc/Hz and -117 dBc/Hz at 1 Hz, 10 Hz, 100 Hz and 1 kHz offset frequencies, respectively. The residual phase noise of the synthesizer is − 82 dBc/Hz at 1 Hz offset frequency. The frequency stability limit due to the absolute phase noise via Dick effect is theoretically estimated to be 7.0 × 10−14τ−1/2.
13 September 2022 in Physical Review A
Motivated by the challenge of identifying intruder ions in a cold ion crystal, we investigate calorimetry from emitted fluorescence light. Under continuous Doppler cooling, the ion crystal reaches a temperature equilibrium with a fixed level of fluorescence intensity and any change in the motional energy of the crystal results in a modification of this intensity. We theoretically determine the fluorescence rate of an ion crystal as a function of the temperature, assuming that laser light is scattered along a two-level electronic transition, which couples to the crystal's vibrations via the mechanical effects of light. We analyze how the heat dissipated by collisions of an incoming intruder ion alters the scattering rate. We argue that an energy change by an incoming ion can be unambiguously detected within 100 via illuminating a fraction of a ion crystal. This method enables applications including capture and spectroscopy of charged states of thorium isotopes and investigation of highly charged ions.