Benjamin Tobias

Benjamin Tobias

Auto-generated profile, based on publicly available information

Benjamin Tobias

Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 May 2020 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
JSJ. P. Sauppe
J. P. Sauppe
SPS. Palaniyappan
S. Palaniyappan
BTB. J. Tobias
B. J. Tobias
JKJ. L. Kline
J. L. Kline
KFK. A. Flippo
K. A. Flippo
EME. Malka
E. Malka
Rayleigh-Taylor instability growth is shown to be hydrodynamically scale invariant in convergent cylindrical implosions for targets that varied in radial dimension and implosion timescale by a factor of 3. The targets were driven directly by laser irradiation providing a short impulse, and instability growth at an embedded aluminum interface occurs as it converges radially inward by a factor of 2.25 and decelerates on a central foam core. Late-time growth factors of 14 are observed for a single-mode m=20 azimuthal perturbation at both scales, despite the differences in laser drive conditions between the experimental facilities, consistent with predictions from radiation-hydrodynamics simulations. This platform enables detailed investigations into the limits of hydrodynamic scaling in high-energy-density systems.

1 February 2018 in Journal of Instrumentation
Verified
Journal Article
Closed access
PDF file
BGB.X. Gao
B.X. Gao
谢锦谢 锦林
谢 锦林
ZMZ. Mao
Z. Mao
Chenglong LuoChenglong Luo
Chenglong Luo
YZY.L. Zhu
Y.L. Zhu
BTB. Tobias
B. Tobias
A 384 channels (24 vertical × 16 radial) Electron Cyclotron Emission Imaging (ECEI) system has been installed on Experimental Advanced Superconducting Tokamak (EAST). With the aid of advanced front optics, high spaital resolution around 1.1cm and flexible vertical coverage 30 ~ 70 cm have been realized. The well-designed optics also provides a long Rayleigh length up to 70 cm even with an object length larger than 2.6 m. The electronic system has a wide immediate frequency (IF) bandwidth 2 ~ 16.5 GHz, which enables a continuous radial coverage up to 25 cm. Benefited from advanced optics design and the wide IF bandwidth, the ECEI system with high spatial resolution can provide a large and continuous view field, especially in the radial direction, which is enough for the observation of the whole q = 1 surface. The comprehensive details of the ECEI system will be presented in this paper, along with some experimental results.

16 March 2011 in Contributions to Plasma Physics
Verified
Journal Article
Closed access
PDF file
BTB. Tobias
B. Tobias
ADA.J.H. Donné
A.J.H. Donné
HPH.K. Park
H.K. Park
JBJ.E. Boom
J.E. Boom
MCM.J. Choi
M.J. Choi
GYGunsu YUN
Gunsu YUN

1 October 2010 in Review of Scientific Instruments
Verified
Journal Article
Open access
PDF file
TLT. Liang
T. Liang
BTB. Tobias
B. Tobias
XKX. Kong
X. Kong
CDC. W. Domier
C. W. Domier
NLN. C. Luhmann
N. C. Luhmann
HPH. K. Park
H. K. Park
The installation of a new electron cyclotron emission imaging diagnostic for the Korea Superconducting Tokamak Advanced Research (KSTAR) is underway, making use of a unique optical port cassette design, which allows placement of refractive elements inside the cryostat region without adverse effects. The result is unprecedented window access for the implementation of a state of the art imaging diagnostic. A dual-array optical design has been developed, capable of simultaneously imaging the high and low field sides of the plasma with independent features of focal plane translation, vertical zoom, and radial channel spacing. The number of translating optics has been minimized by making use of a zoom lens triplet and parabolic plasma facing lens for maximum channel uniformity over a continuous vertical zoom range of 3:1. The simulated performance of this design is presented along with preliminary laboratory characterization data.

1 August 2020 in High Energy Density Physics
Verified
Journal Article
Closed access
JSJ.P. Sauppe
J.P. Sauppe
SPS. Palaniyappan
S. Palaniyappan
JKJ.L. Kline
J.L. Kline
KFK.A. Flippo
K.A. Flippo
OLO.L. Landen
O.L. Landen
EME. Malka
E. Malka

1 March 2021 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
UDUniversity of California Davis
University of California Davis
YZY. Zhu
Y. Zhu
YWY. Wang
Y. Wang
OMO. Meneghini
O. Meneghini
SSS. P. Smith
S. P. Smith
NLN. C. Luhmann
N. C. Luhmann
An Electron Cyclotron Emission Imaging (ECEI) data analysis module has been developed for the OMFIT platform to accommodate the needs of users at the DIII-D tokamak for physics applications. The user can easily access the ECEI spatial observation windows in the plasma that are calculated based on the automatically retrieved hardware setup and available DIII-D equilibria, perform spectral analysis, and obtain 2D electron temperature fluctuation images. The module provides a powerful data post-processing package for extracting important physics parameters from the 2D measurements, including the radial structure and poloidal mode number of Alfven eigenmodes, as well as the frequency-vs-wavenumber dispersion relationship of broadband MHD. The module propagates characterized synthetic fluctuations for the user, so one can perform forward modeling tasks with simple analytical fluctuations.