1 February 2018 in Journal of Instrumentation
Verified
Journal Article
Closed access
PDF file
BGB.X. Gao
B.X. Gao
谢锦谢 锦林
谢 锦林
ZMZ. Mao
Z. Mao
Chenglong LuoChenglong Luo
Chenglong Luo
YZY.L. Zhu
Y.L. Zhu
BTB. Tobias
B. Tobias
A 384 channels (24 vertical × 16 radial) Electron Cyclotron Emission Imaging (ECEI) system has been installed on Experimental Advanced Superconducting Tokamak (EAST). With the aid of advanced front optics, high spaital resolution around 1.1cm and flexible vertical coverage 30 ~ 70 cm have been realized. The well-designed optics also provides a long Rayleigh length up to 70 cm even with an object length larger than 2.6 m. The electronic system has a wide immediate frequency (IF) bandwidth 2 ~ 16.5 GHz, which enables a continuous radial coverage up to 25 cm. Benefited from advanced optics design and the wide IF bandwidth, the ECEI system with high spatial resolution can provide a large and continuous view field, especially in the radial direction, which is enough for the observation of the whole q = 1 surface. The comprehensive details of the ECEI system will be presented in this paper, along with some experimental results.

1 October 2022 in Physics of Plasmas
Verified
Journal Article
Closed access
PDF file
LSLonglong Sang
Longlong Sang
QLQuanming Lu
Quanming Lu
谢锦谢 锦林
谢 锦林
FFFeibin Fan
Feibin Fan
QZQiaofeng Zhang
Qiaofeng Zhang
XSXuan Sun
Xuan Sun
This paper investigates energy dissipation during electron-scale magnetic reconnection with laboratory experiments. Magnetic fields with opposite directions are generated by two parallel identical pulsed currents in our Keda linear magnetized plasma device. Magnetic reconnection is realized in the rising phase of the pulsed currents. The ramp-up rate of the pulsed current is found to be proportional to the inflow speed, providing a method to modify the reconnection drive. The incoming magnetic energy and its dissipation into plasma energy have been estimated in the vicinity of the X line. It is found that the plasma energy converted from the incoming electromagnetic energy increases with the increasing reconnection drive, while the conversion ratio remains almost unchanged, which is about 10%.

1 December 2014 in Journal of Instrumentation
Verified
Journal Article
Closed access
PDF file
CLC. Luo
C. Luo
BTB.J. Tobias
B.J. Tobias
BGB. Gao
B. Gao
YZY. Zhu
Y. Zhu
谢锦谢 锦林
谢 锦林
WLW. Liu
W. Liu

1 February 2024 in Review of Scientific Instruments
Verified
Journal Article
Open access
PDF file
SQShasha Qiu
Shasha Qiu
LHLogan Himes
Logan Himes
CDCalvin Domier
Calvin Domier
XTXiaopin Tang
Xiaopin Tang
XLXianzi Liu
Xianzi Liu
ZWZhengwei Wu
Zhengwei Wu
A carefully designed waveguide-based millimeter-wave notch filter, operating at 140 GHz, safeguards plasma diagnostic instruments from gyrotron leakage. Utilizing cylindrical cavity resonators with aperture coupling, the filter efficiently resonates 140 GHz wave-power into the TE11p mode, optimizing various geometrical parameters for practical fabrication and high-yield production. Thorough thermal analysis ensures its ability to handle power. The filter achieves outstanding performance with over 90 dB rejection at 140 GHz while providing low insertion loss over the passband (110–138 GHz), which is ideally suited for system-on-chip approach F-band diagnostic system applications.

1 June 2015 in Chinese Physics Letters
Verified
Journal Article
Closed access
PDF file
AHAZAM Hussain
AZAM Hussain
BGBing-Xi Gao
Bing-Xi Gao
WLWan-Dong Liu
Wan-Dong Liu
谢锦谢 锦林
谢 锦林

1 May 2016 in Journal of Instrumentation
Verified
Journal Article
Closed access
XMX.D. Ma
X.D. Ma
ZYZ.J. Yang
Z.J. Yang
YZY.L. Zhu
Y.L. Zhu
XPX.M. Pan
X.M. Pan
YXY. Xiao
Y. Xiao
谢锦谢 锦林
谢 锦林
An electron cyclotron emission imaging (ECEI) system is being developed for J-TEXT. It is comprised of two 16-channel antenna arrays that share the same toroidal window for the purpose of observing separate radial regions of the tokamak plasma simultaneously. Two imaging optic units have been designed, which share the same zoom lenses, but have different focus lenses. The setup is flexible and achieves good spatial resolution. In particular, the poloidal zoom factor can achieve 1.17 to 2.20. The desired focal plane can range anywhere from high field side (HFS) edge to low field side (LFS) edge. The effective field curvature adjustment (FCA) lenses have been adopted for the ECEI imaging optic system, which make the image plane flat enough to match the emission layer in order to increase the image quality.