This work presents a comparative case study, through computational simulations using Matlab software, between the installation of a conventional PV system and a hybrid PV/T system in a hotel located in Vila Velha–ES, where water heating for 45 suites is carried out by electric showers. The simulations considered meteorological data (solar irradiance and ambient temperature), an electrical consumption profile obtained through measurement, as well as installation constraints related to available area and shading. The results indicated that, although the PV/T system has a lower peak power and occupies a smaller area, it demonstrates superior performance when considering the total energy balance. The main advantage observed was a 12.07% reduction in total load consumption, resulting from the use of thermal energy for water heating, which reduces electrical demand. This substitution led to a decrease in grid consumption and an increase of 284.5% in the financial credit generated at the end of the simulated period. The findings demonstrate that the PV/T system represents a more efficient solution for facilities with high water heating demand, optimizing space utilization and contributing to the reduction of electrical grid load. Keywords: Hybrid Photovoltaic/Thermal System; Photovoltaic System; Energy Efficiency; Water Heating; Computational Simulation.
29 November 2025 in Latin American Journal of Energy Research
Este trabalho apresenta uma análise teórica do aproveitamento do calor residual gerado em uma planta híbrida de incineração de resíduos sólidos urbanos (RSU) e energia termossolar concentrada (PTC). O sistema estudado opera 24/7, com um fluxo de 27,04 kg/s de RSU e produção contínua de 77 MW, sem armazenamento. A temperatura do calor residual varia entre 220°C e 788°C ao longo do dia. Avalia-se a viabilidade de produção de hidrogênio através de reforma termoquímica e SOEC durante as horas de alta temperatura e a utilização do calor residual noturno para secagem da biomassa ou processos térmicos auxiliares. O estudo considera parâmetros médios de eficiência da literatura sendo o rendimento da reforma de 35% e rendimento do SOEC de 30%. Os resultados indicam que o calor residual pode gerar entre 12 e 18 kg de H₂ por tonelada de RSU durante o dia, pelas rotas tecnológica de SOEC e de reforma termoquímica respectivamente, enquanto o calor noturno pode ser aproveitado para processos de secagem, aumentando a eficiência global do sistema e reduzindo desperdícios energéticos. O trabalho fornece uma base teórica para futuras implementações e otimizações em plantas híbridas urbanas de geração de energia.