26 May 2017 in IEEE Transactions on Smart Grid
In a smart dc microgrid, power electronic devices limit the current during fault and therefore, an overcurrent-based relaying scheme cannot provide required sensitivity and selectivity for such a system. For a dc microgrid with ring configuration having bidirectional power flow, the protection design is further complicated. For reliable supply to customers and to avoid unwanted disconnection of renewable resources, selectivity of a protection scheme is important. In this paper, using local voltage and current data, a least square-based technique estimates the parameter of the fault path, from which the direction of the fault is inferred. Using the direction of fault information of both ends of a line segment in a ring system, internal and external faults are discriminated for network protection. Using PSCAD/EMTDC simulations for a ring system, proposed method is tested for various fault situations including high resistance fault, close-in fault, signals with noise, and considering different modes of distributed generation operations. The proposed algorithm is also validated on a scaled-down hardware setup in the laboratory. The method is found to be more accurate compared to available technique.
11 May 2018 in IEEE Transactions on Smart Grid
With enhanced processing capacity and communication infrastructure available in smart grid platform, unit protection scheme is a promising technique. High resistance fault is a problem with current differential and current direction based unit protection solutions. In this letter, a protection scheme capable of fast fault detection and reliable selectivity for DC microgrid is proposed. The method uses superimposed currents of both ends of a line segment presented on i-plane during fault to derive protection decision. Using PSCAD/EMTDC simulations, performance of the proposed method is evaluated, compared and found to be accurate.
5 June 2018 in IEEE Systems Journal
A fast and accurate protection scheme for a dc microgrid enhances the service reliability and improves the power quality. A fault in any section of a dc microgrid results in oscillation in current, where its frequency is a function of fault position. The frequency and associated transient power of the first cycle of the oscillation are used for fault detection and faulted section identification, respectively. Based on the inverse-time transient power, a relay coordination scheme is proposed for the faulted section isolation in a dc ring bus microgrid. The maloperation of a relay due to the communication failure in the unit protection scheme can be averted by applying the proposed method using local data. The performance of the method is tested using data obtained from PSCAD/EMTDC simulations for numerous cases including bidirectional power flow situation, high fault resistance, and different fault types. The proposed algorithm is also validated on a scaled-down hardware setup in the laboratory.
19 February 2021 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Unlike the phasor measurement-based protection in ac systems, the protection of dc systems deals with complex fault transients which mandate the isolation of the faulted segment within few milliseconds as continued fault current leads to overheating issue in power electronic converters. To this end, several works have been suggested-based on the unit and nonunit protections for dc microgrids. Threshold selection and protection coordination are the challenges associated with nonunit protection. Similarly, communication delay and link failure limit the application of unit protection. To address these issues, this article presents a robust centralized protection scheme for dc microgrids, which is resilient to communication delay and link failure. It uses the current of each line segment to compute the similarity of current change at both ends of the line segment to derive the protection decision. To overcome the communication failure from one end of the line segment or even from multiple segments, the proposed method uses data from adjacent segments to derive the protection decision correctly. Using power systems computer aided design (PSCAD)/electromagnetic transients and direct current (EMTDC) environment, the performance of the proposed method is evaluated for various cases and compared with available techniques. Finally, the accuracy of the protection algorithm is validated under experimental conditions.
14 November 2022 in IEEE Journal of Emerging and Selected Topics in Power Electronics
With increased cyber infrastructure in large power systems with inverter-based resources (IBRs), it remains highly susceptible to cyber attacks. Reliable and secure operations of such system under a large signal disturbance necessitate an anomaly diagnosis scheme, which is substantial for either selective operation of relays (during grid faults), or cybersecurity (during cyber attacks). This becomes a challenge for power electronic systems, as their characteristic response to such large signal disturbance is very fast. Hence, we accumulate our efforts in this paper to characterize between them accurately within a short time frame. A novel non-invasive anomaly diagnosis mechanism for IBRs is presented, which only requires locally measured voltage and frequency as inputs. Mapping these inputs in a X-Y plane, the characterization process is able to classify between the anomalies within 5 ms. To the best of our knowledge, this mechanism provides the fastest decision in comparison to the existing techniques, which also assists the equipped protection/cybersecurity technology to take corresponding decisions without enforcing any customization. The proposed scheme is validated on many systems using real-time (RT) simulations in OPAL-RT environment with HYPERSIM software and also on a hardware prototype. The results verify the effectiveness, scalability and accuracy of the proposed mechanism under different scenarios.