27 April 2022 in IEEE/ASME Transactions on Mechatronics
This article presents a Lissajous scanning confocal endomicroscopy comprising an easily manufacturable thin polyimide (PI) film and modified phase-offset-driven scanning. The Lissajous scanning confocal probe has a piezoelectric tube actuator and the PI film-attached fiber cantilever designed to resonate with the lever mechanism. Data from a finite element analysis and experiments are used to optimize the dimensions of the PI film, which produces a frequency separation and field of view of $195\;{\bf{Hz}}$ and $180\;\mu {\bf{m}}\; \times \;180\;\mu {\bf{m}}$ , respectively, at driving voltages less than $30\;{{\bf{V}}_{pp}}$ . The best combination of decimal frequencies with optimized driving phase offsets is determined to achieve a scanning density (SD) exceeding $80\% $ consistently with an imaging speed of $8\;{\bf{Hz}}$ . By analyzing the Lissajous patterns at different decimal frequency combinations via time-delay analysis, it is possible to find more diverse combinations that meet the SD criterion. When the scanning patterns deviate from the desired paths, the proposed modified phase-offset-driven method is applied to maintain the best scanning pattern. The USAF 1951 test pattern, several plants, and rat gastrointestinal tract were imaged successfully using the confocal endomicroscopic system with the PI film and modified phase-offset-driven scanning.
26 July 2023 in International Journal of Optomechatronics
25 October 2024 in Machine Learning: Science and Technology
Diabetes is a global health issue affecting millions of people and is related to high morbidity and mortality rates. Current diagnostic methods are primarily invasive, involving blood sampling, which can lead to infection and increased patient stress. As a result, there is a growing need for noninvasive diabetes diagnostic methods that are both accurate and fast. High measurement accuracy and fast measurement time are essential for effective noninvasive diabetes diagnosis; these can be achieved using diffuse speckle contrast analysis (DSCA) systems and artificial intelligence algorithms. In this study, we use a machine learning algorithm to analyze rat blood flow signals measured using a DSCA system with simple operation, easy fabrication, and fast measurement for helping diagnose diabetes. The results confirmed that the machine learning algorithm for analyzing blood flow oscillation data shows good potential for diabetes classification. Furthermore, analyzing the blood flow reactivity test revealed that blood flow signals can be quickly measured for diabetes classification. Finally, we evaluated the influence of each blood flow oscillation data on diabetes classification through feature importance and Pearson correlation analysis. The results of this study should provide a basis for the future development of hemodynamic-based disease diagnostic methods.
11 February 2026 in Sensors and Actuators A: Physical