27 April 2022 in IEEE/ASME Transactions on Mechatronics
This article presents a Lissajous scanning confocal endomicroscopy comprising an easily manufacturable thin polyimide (PI) film and modified phase-offset-driven scanning. The Lissajous scanning confocal probe has a piezoelectric tube actuator and the PI film-attached fiber cantilever designed to resonate with the lever mechanism. Data from a finite element analysis and experiments are used to optimize the dimensions of the PI film, which produces a frequency separation and field of view of $195\;{\bf{Hz}}$ and $180\;\mu {\bf{m}}\; \times \;180\;\mu {\bf{m}}$ , respectively, at driving voltages less than $30\;{{\bf{V}}_{pp}}$ . The best combination of decimal frequencies with optimized driving phase offsets is determined to achieve a scanning density (SD) exceeding $80\% $ consistently with an imaging speed of $8\;{\bf{Hz}}$ . By analyzing the Lissajous patterns at different decimal frequency combinations via time-delay analysis, it is possible to find more diverse combinations that meet the SD criterion. When the scanning patterns deviate from the desired paths, the proposed modified phase-offset-driven method is applied to maintain the best scanning pattern. The USAF 1951 test pattern, several plants, and rat gastrointestinal tract were imaged successfully using the confocal endomicroscopic system with the PI film and modified phase-offset-driven scanning.
26 July 2023 in International Journal of Optomechatronics
29 December 2023 in International Journal of Optomechatronics
27 March 2024 in IEEE/ASME Transactions on Mechatronics
Piezoelectric (PZT) tube actuators have been widely used in miniature resonant scanning systems due to their low operation voltage and high-frequency bandwidth. Although several designs of asymmetric stiffeners have been implemented to mitigate the inherent parasitic deflection of PZT actuators, to the best of the authors' knowledge, finite element analysis (FEA) has only been used to predict the harmonic response of asymmetric fiber cantilevers. This study presents the analytical modeling of an arbitrary-shaped resonant fiber cantilever based on Castigliano's and Rayleigh–Ritz's methods. The proposed model is designed to quickly identify and adjust the influential variables of asymmetric stiffeners, comparable to FEA in terms of its high prediction accuracy and fewer numerical computations. In addition, a thermoplastic polystyrene sheet was adopted to fabricate the asymmetric stiffener due to its sufficient stiffness, low cost, and high fabrication repeatability. The proposed model could accurately predict frequency separation at various fabrication tolerances, with the most significant errors from the experiments of 3.21%, comparable to FEA prediction results of 3.00%. Imaging results were acquired from an ex-vivo rat's stomach and small intestine using the implemented asymmetric fiber cantilever and compared with their histological images.
20 August 2025 in IEEE/ASME Transactions on Mechatronics
This study presents a compact sensor for simultaneous force measurement and depth profiling. We have developed a fiber-optic sensor structure capable of integrating common-path optical coherence tomography (CP-OCT) and Fabry–Pérot Interferometry (FPI) within a single unit. The proposed FPI-OCT sensor, with an outer diameter of 0.25 mm, is encased in a 0.41 mm hypodermic tube. Analytical models were developed for efficient beam path optimization and signal interpretation, where multiple common-path references yielded distinct interferometric signals. The sensor has a sufficiently high sampling rate of 780 Hz for both CP-OCT and FPI signal processing using parallel computing. The fabricated sensor achieved a measurable force range of approximately 5 N with a resolution of 0.119 mN, and a depth sensing range of 3.6 mm with an axial resolution of 6.0 ${\mu }$m. Furthermore, injection experiments with multilayered phantoms and ex vivo porcine eyes demonstrated that the sensor could simultaneously measure force and depth profiles, providing enriched information during the tasks.
2 January 2026 in Biomedical Optics Express
We present dynamic spectrally encoded confocal microscopy (D-SECM), a high-speed, label-free imaging modality for real-time visualization of subcellular metabolic activity. Sequential, optically sectioned SECM images, with a lateral resolution of 0.62 µm–0.88 µm, were acquired at 100 fps by a modified swept source SECM system, stabilized by fiber-Bragg grating swept source synchronization. D-SECM images are created through real-time pixelwise power spectra mapping into frequency-dependent RGB channels, enabled by GPU-accelerated parallel processing. Validation on freshly excised mouse liver tissue demonstrates that metabolic contrast is detectable with exposure durations as short as 40 ms in the liver. Moreover, volume-prioritized scanning enables three-dimensional D-SECM images to be acquired within a second. In addition to the liver, D-SECM has also been demonstrated in multiple organs, including the lung, thyroid, kidney, and pancreas. These capabilities position D-SECM as a powerful and scalable platform for high-speed, label-free imaging of metabolic dynamics, with unique potential for both basic research and real-time clinical applications.