Xue Zhang

Xue Zhang

Auto-generated profile, based on publicly available information

Xue Zhang

Institute for Interdisciplinary Medicine and Engineering Shenzhen Technology University Shenzhen China

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 July 2023 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
Yisen HuangYisen Huang
Yisen Huang
WLWeibin Li
Weibin Li
XZXue Zhang
Xue Zhang
JLJixiu Li
Jixiu Li
YLYehui Li
Yehui Li
RTRaymond Kai-yu Tong
Raymond Kai-yu Tong
Endoscopes provide views inside the patient's body during minimally invasive surgery. Although various robotic endoscopes have been developed to reduce surgeons' workload in manual endoscope operations, autonomous endoscope manipulation remains challenging due to the misorientation effect and different disturbances. In this work, we developed an intelligent endoscope system to steer the surgical view automatically. To keep the target (i.e., the tip of an instrument) at the center of the camera view with a suitable size and orientation, an image moment-based 4-degree-of-freedom (DOF) visual servoing method is implemented. We propose an error learning-based sliding mode controller to realize fast and smooth error convergence. It is specially constructed to improve convergence rate without causing undesirable system chattering. Moreover, the kinematic modeling of the endoscope results in a quadratic programming problem, which is solved by a novel adaptive noise-immune zeroing neural network accelerated to predefined-time convergence by a newly constructed activation function. The experiments show that the proposed control strategy guarantees a superior convergence rate and robustness compared with existing methods. Lab tests show the application potential of the proposed endoscope system in clinical practice.

22 November 2024 in IEEE Transactions on Systems, Man, and Cybernetics: Systems
Verified
Journal Article
Open access
Yisen HuangYisen Huang
Yisen Huang
JLJian Li
Jian Li
WLWeibin Li
Weibin Li
XZXue Zhang
Xue Zhang
YSYichong Sun
Yichong Sun
RTRaymond Kai-yu Tong
Raymond Kai-yu Tong
In minimally invasive surgery (MIS), the field of view (FOV) control is crucial. Autonomous endoscope robots have been developed to facilitate MIS procedures by enabling autonomous surgical target tracking, thus reducing the workload on surgeons. However, existing visual servoing-based target tracking methods for autonomous endoscopes often overlook the insecurity stemming from restricted workspace conditions. Instances, such as collisions between the endoscope robot’s tip and the patient’s chest or abdominal wall pose risks to patient tissue, while extensive motion of the endoscope shaft may damage incision port tissue. Addressing these security concerns, this article proposes a novel approach called virtual fixture-based restricted workspace constraint (RWSC) to reconstruct the endoscope robot’s movement range. A quadratic programming (QP) optimization framework is employed to govern the robot’s motion, ensuring autonomous target tracking while adhering to RWSCs. To solve the QP problem, we propose an adaptive zeroing neural network (ZNN) featuring a newly designed activation function (AF). This AF enhances the ZNN with predefined-time convergence and noise rejection capabilities, making it especially suitable for time-sensitive and noise-prone surgical applications. Theoretical analysis and experimental results demonstrate that our adaptive ZNN achieves shorter convergence times than existing neural dynamic-based QP solvers. Physical validations show the efficacy of the proposed RWSCs in limiting the workspace of the endoscope robot, while the FOV control strategy enables autonomous target tracking of flexible endoscopes under diverse constraints and objectives.

1 December 2018 in Journal of Petroleum Science and Engineering
Verified
Journal Article
Closed access
HJHang Jiang
Hang Jiang
XPXiongqi Pang
Xiongqi Pang
DCDi Chen
Di Chen
HPHuijie Peng
Huijie Peng
QYQiuhua Yu
Qiuhua Yu
XZXue Zhang
Xue Zhang

30 May 2021
Verified
Conference Paper
Closed access
XZXue Zhang
Xue Zhang
WLWeibin Li
Weibin Li
WNWing Yin Ng
Wing Yin Ng
Yisen HuangYisen Huang
Yisen Huang
YXYitian Xian
Yitian Xian
RTRaymond Kai-yu Tong
Raymond Kai-yu Tong
In this paper, we proposed an autonomous robotic flexible endoscope system for the laparoscopic bariatric surgery (LBS). This system comprises a UR5 robot and a flexible endoscope equipped with a novel continuum joint, named reinforced double helix continuum mechanism. Compared with the simple helix structure, the compressional and torsional stiffness of the proposed joint are improved significantly. To automate the robotic flexible endoscope, image-based visual servoing technique is employed. A deep learning algorithm named TernausNet-16 is improved and incorporated into the control framework to detect surgical instruments inside the camera view. The experimental studies verified the effectiveness and feasibility of the robotic flexible endoscope system for the visual serviong control scheme assisted by deep learning methods.

18 January 2022 in Mechanism and Machine Theory
Verified
Journal Article
Closed access
XZXue Zhang
Xue Zhang
YXYitian Xian
Yitian Xian
ZCZhiwei Cui
Zhiwei Cui
PCPhilip Wai Yan Chiu
Philip Wai Yan Chiu
ZLZheng Li
Zheng Li

1 December 2014 in Inverse Problems
Verified
Journal Article
Closed access
XZXue Zhang
Xue Zhang
WZWeifeng Zhou
Weifeng Zhou
XZXiaoqun Zhang
Xiaoqun Zhang
HGHao Gao
Hao Gao