David J. Liesker

David J. Liesker

Auto-generated profile, based on publicly available information

David J. Liesker

Department of Surgery (Division of Vascular Surgery), University Medical Center Groningen, University of Groningen, Groningen, The Netherlands

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 October 2022 in Journal of Vascular Surgery
Verified
Journal Article
Open access
DLDavid J. Liesker
David J. Liesker
BGBarzi Gareb
Barzi Gareb
RLRick S. Looman
Rick S. Looman
SDSimone J.A. Donners
Simone J.A. Donners
GBGert J. de Borst
Gert J. de Borst
BSBen R. Saleem
Ben R. Saleem
Patch angioplasty during carotid endarterectomy (CEA) is commonly used to treat carotid artery stenosis. However, the choice of which patch to use remains a matter of debate. Autologous venous material has disadvantages such as wound-related problems at the harvest site and a prolonged intervention time. These limitations can be bypassed when synthetic or biological patches are used. Both materials have been associated with divergent advantages and disadvantages. Therefore, the aim of our study was to compare the long-term follow-up outcomes in patients who underwent CEA and closure with either a bovine pericardial patch (BPP) or polyester patch. A retrospective cohort study was conducted including all patients who underwent primary CEA and closure with a BPP or a polyester patch between January 2010 and December 2020 at our tertiary referral center. In 2015, the BPP was introduced as an alternative for polyester. The primary outcome was the occurrence of transient ischemic attack (TIA) or cerebrovascular accident (CVA) during follow-up and secondary outcomes included restenosis, reintervention, all-cause mortality, and patch infection. Cox proportional hazard models were used and hazard ratios with 95% confidence intervals were used to predict these outcomes. We included 417 CEA patients; 254 patients (61%) received a BPP and 163 received (39%) a polyester patch. The mean age was 70.2 ± 8.7 years and 67% were male. The median follow-up time was 15 months (range, 12-27 months) for BPP and 42 months (range, 16-60 months) for polyester (P < .001). Postoperative hematoma (≤30 days) was significantly lower in the BPP cohort (2% BPP vs 6% polyester; P = .047). No other significant differences on short-term outcomes were found. Univariable Cox regression analyses showed no significant differences between the effect estimates of polyester and BPP on TIA or CVA (P = .106), restenosis (P = .211), reintervention (P = .549), or all-cause mortality (P = .158). No significant differences were found after adjusting for confounders in the multivariable analyses: TIA or CVA (P = .939), restenosis (P = .057), reintervention (P = .193) and all-cause mortality (P = .742). Three patients with a polyester patch had patch infection compared with none of the patients in the group who received a BPP. This large retrospective study showed comparable safety and durability of both BPP and polyester suggesting that both patch types can be safely applied for CEA with patch angioplasty. Patch infection was rare and was absent in the BPP group.

30 January 2022 in Annals of Vascular Surgery
Verified
Journal Article
Open access
DLDavid J. Liesker
David J. Liesker
DMDouwe Johannes Mulder
Douwe Johannes Mulder
MWMarjan Wouthuyzen-Bakker
Marjan Wouthuyzen-Bakker
NPNiek Prakken
Niek Prakken
RSRiemer H.J.A. Slart
Riemer H.J.A. Slart
BSBen R. Saleem
Ben R. Saleem
The existing literature on mycotic aortic aneurysm is scarce and focuses on treatment. This study evaluates the clinical characteristics, diagnostics, treatment and outcome of patients with a mycotic abdominal aortic aneurysm treated in a tertiary referral center. A retrospective cohort study was conducted including all patients with a proven mycotic abdominal aortic aneurysm admitted between May 2010 and July 2020. Primary outcome was mortality and secondary outcome included complications such as vascular graft/endograft infection. Twenty-four patients with a mycotic abdominal aortic aneurysm were included. Patients had a mean age of 68 ± 9 years and 20 (83%) were male. Thirteen patients (57%) had positive preoperative blood cultures. Streptococcus pneumoniae was most frequently isolated by blood culturing, pus, and vascular, or perivascular tissue cultures (17%). In 19 (83%) patients the mycotic abdominal aortic aneurysm was located infrarenally, in three (13%) patients suprarenally, and in one (4%) patient juxtarenally. Median follow-up was 20 (7-42) months. In 8 patients (33%) vascular graft and or endograft infection was diagnosed after surgical repair. Ten (42%) patients died during the follow-up period. The main causes of death were vascular graft/endograft infection-related (n = 4) and rupture of the mycotic abdominal aortic aneurysm (n = 3). No patient characteristics could be identified as predictive for mortality. This study shows a large variation in presentation, diagnostic approaches, and surgical and antibiotic treatment of mycotic abdominal aortic aneurysm. The detailed information about the diagnostic approaches to this rare disease and its antibiotic and/or other treatment contributes to existing knowledge of mycotic abdominal aortic aneurysm. Because of the individual variation patients should be discussed in a multidisciplinary team with a vascular surgeon, infectious disease specialist, and clinical microbiologist.

25 May 2023 in Annals of Vascular Surgery
Verified
Journal Article
Open access
DLDavid J. Liesker
David J. Liesker
BGBarzi Gareb
Barzi Gareb
MSMaarten J. Speijers
Maarten J. Speijers
JVJoost R. van der Vorst
Joost R. van der Vorst
PSPieter B. Salemans
Pieter B. Salemans
BSBen R. Saleem
Ben R. Saleem
Background: Vascular graft/endograft infection is a rare but life-threatening complication of cardiovascular surgery and remains a surgical challenge. Several different graft materials are available for the treatment of vascular graft/endograft infection, each having its own advantages and disadvantages. Biosynthetic vascular grafts have shown low reinfection rates and could be a potential second best after autologous veins in the treatment of vascular graft/endograft infec-tion. Therefore, the aim of our study was to evaluate the efficacy and morbidity of Omniflow (R) II for the treatment of vascular graft/endograft infection. Methods: A multicenter retrospective cohort study was performed to evaluate the use of Omni-flow (R) II in the abdominal and peripheral region to treat vascular graft/endograft infection be-tween January 2014 and December 2021. Primary outcome was recurrent vascular graft infection. Secondary outcomes included primary patency, primary assisted patency, secondary patency, all-cause mortality, and major amputation. Results: Fifty-two patients were included with a median follow-up duration of 26.5 (10.8e54.8) months. Nine (17%) grafts were implanted in intracavitary position and 43 (83%) in peripheral position. Most grafts were used as femoral interposition (n = 12, 23%), femoro-femoral cross-over (n = 10, 19%), femoro-popliteal (n = 8, 15%), and aorto-bifemoral (n = 8, 15%) graft. Fifteen (29%) grafts were implanted extra-anatomically and 37 (71%) in situ. Eight patients (15%) presented with reinfection during follow-up, most of these patients received an aorto-bifemoral graft (n = 3, 38%). Intracavitary vascular grafting had a 33% (n = 3) reinfection rate and peripheral grafting 12% (n = 5; P = 0.025). The estimated primary patencies at 1, 2, and 3 years were 75%, 72%, and 72% for peripherally located grafts and 58% (at all timepoints) for intracavitary grafts (P = 0.815). Secondary patencies at 1, 2, and 3 years were 77% (at all timepoints) for peripherally located prostheses and 75% (at all timepoints) for intracavitary prostheses (P = 0.731). A significantly higher mortality during follow-up was observed in patients who received an intracavitary graft compared to patients with a peripheral graft (P = 0.003). Conclusions: This study highlights the efficacy and safety of the Omniflow (R) II biosynthetic prosthesis for the treatment of vascular graft/endograft infection, in absence of suitable venous material, with acceptable reinfection, patency, and freedom of amputation prevalences, especially in replacing peripheral vascular graft/endograft infection. However, a control group with either venous reconstruction or another alternative graft is needed to make firmer conclusions.

29 July 2023 in European Journal of Nuclear Medicine and Molecular Imaging
Verified
Journal Article
Open access
PDF file
DLDavid J. Liesker
David J. Liesker
SLStijn Legtenberg
Stijn Legtenberg
PEPaola A. Erba
Paola A. Erba
AGAndor W. J. M. Glaudemans
Andor W. J. M. Glaudemans
CZClark J. Zeebregts
Clark J. Zeebregts
RSRiemer H. J. A. Slart
Riemer H. J. A. Slart
Purpose: 18F-fluoro-D-deoxyglucose positron emission tomography with low dose and/or contrast enhanced computed tomography ([18F]FDG-PET/CT) scan reveals high sensitivity for the diagnosis of vascular graft and endograft infection (VGEI), but lower specificity. Reporting [18F]FDG-PET/CT scans of suspected VGEI is challenging, reader dependent, and reporting standards are lacking. The aim of this study was to evaluate variability of [18F]FDG-PET/low dose CT (LDCT) reporting of suspected VGEI using a proposed standard reporting format. Methods: A retrospective cohort study was conducted including all patients with a suspected VGEI (according to the MAGIC criteria) without need for urgent surgical treatment who underwent an additional [18F]FDG-PET/LDCT scan between 2006 and 2022 at a tertiary referral centre. All [18F]FDG-PET/LDCT reports were scored following pre-selected criteria that were formulated based on literature and experts in the field. The aim was to investigate the completeness of [18F]FDG-PET/LDCT reports for diagnosing VGEI (proven according to the MAGIC criteria) and to evaluate if incompleteness of reports influenced the diagnostic accuracy. Results: Hundred-fifty-two patients were included. Median diagnostic interval from the index vascular surgical procedure until [18F]FDG-PET/LDCT scan was 35.5 (7.3–73.3) months. Grafts were in 65.1% located centrally and 34.9% peripherally. Based on the pre-selected reporting criteria, 45.7% of the reports included all items. The least frequently assessed criterion was FDG-uptake pattern (40.6%). Overall, [18F]FDG-PET/LDCT showed a sensitivity of 91%, a specificity of 72%, and an accuracy of 88% when compared to the gold standard (diagnosed VGEI). Lower sensitivity and specificity in reports including ≤ 8 criteria compared to completely evaluated reports were found (83% and 50% vs. 92% and 77%, respectively). Conclusion: Less than half of the [18F]FDG-PET/LDCT reports of suspected VGEI met all pre-selected criteria. Incompleteness of reports led to lower sensitivity and specificity. Implementing a recommendation with specific criteria for VGEI reporting is needed in the VGEI-guideline update. This study provides a first recommendation for a concise and complete [18F]FDG-PET/LDCT report in patients with suspected VGEI.

5 February 2023 in Biology
Verified
Journal Article
Open access
PDF file
NRNick van Rijsewijk
Nick van Rijsewijk
JHJasper H. G. Helthuis
Jasper H. G. Helthuis
Andor W. J. M. GlaudemansAndor W. J. M. Glaudemans
Andor W. J. M. Glaudemans
MWMarjan Wouthuyzen-Bakker
Marjan Wouthuyzen-Bakker
NPNiek Prakken
Niek Prakken
Riemer H.J.A. SlartRiemer H.J.A. Slart
Riemer H.J.A. Slart
Vascular graft and endograft infections (VGEI) cause a serious morbidity and mortality burden. 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) imaging is frequently used in the diagnostic workup, but the additional value of abnormal (18F-FDG active and/or enlarged) locoregional lymph nodes is unknown. In this retrospective study, the additional diagnostic value of abnormal locoregional lymph nodes on 18F-FDG PET/CT imaging for VGEI was evaluated, including 54 patients with a culture-proven VGEI (defined according to the Management of Aortic Graft Infection [MAGIC] group classification) and 25 patients without VGEI. 18F-FDG PET/CT was qualitatively and quantitatively assessed for tracer uptake and pattern at the location of the vascular graft, and locoregional lymph node uptake and enlargement (>10 mm). 18F-FDG uptake intensity and pattern independently predicted the presence of VGEI by logistic regression (Χ2: 46.19, p < 0.001), with an OR of 7.38 (95% CI [1.65, 32.92], p = 0.009) and 18.32 (95% CI [3.95, 84.88], p < 0.001), respectively. Single visual assessment of abnormal locoregional lymph nodes predicted the presence of VGEI with a sensitivity of 35%, specificity of 96%, PPV of 95%, and NPV of 41%. The visual assessment of abnormal lymph nodes after qualitative assessment of 18F-FDG uptake intensity and pattern at the vascular graft location did not independently predict the presence of VGEI by logistic regression (Χ2: 3.60, p = 0.058; OR: 8.25, 95% CI [0.74, 63.37], p = 0.096). In conclusion, detection of abnormal locoregional lymph nodes on 18F-FDG PET/CT has a high specificity (96%) and PPV (95%) for VGEI. However, it did not add to currently used 18F-FDG PET/CT interpretation criteria.

9 May 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
BSBerend G. C. Slijkhuis
Berend G. C. Slijkhuis
DLDavid J. Liesker
David J. Liesker
SKSherilyn A.C. Konter
Sherilyn A.C. Konter
APAnnet Possel-Nicolai
Annet Possel-Nicolai
RBReinoud Bokkers
Reinoud Bokkers
DMDouwe Johannes Mulder
Douwe Johannes Mulder
Inflammatory abdominal aortic aneurysms (iAAA) are a form of noninfectious aortitis in patients with abdominal aortic aneurysms (AAA). Ultrasound could help to detect iAAA early. This retrospective observational study assessed the potential of using ultrasound to detect iAAA in a case series of iAAA patients, and the diagnostic value of ultrasound to detect iAAA in consecutive patients in a follow-up for AAA, referred to as a feasibility study. In both studies, diagnosis of iAAA was based on a cuff surrounding the aneurysm using CT (golden standard). The case series included 13 patients (age 64 (61; 72) years; 100% male). The feasibility study included 157 patients (age 75 (67; 80) years; 84% male). In the case series, all iAAA patients showed a cuff surrounding the aortic wall on ultrasound. In the feasibility study with AAA patients, ultrasound yielded no cuff in 147 (93.6%; CT negative in all cases), a typic cuff in 8 (5.1%; CT positive in all cases), and an inconclusive cuff in 2 (1.3%; CT negative in both cases) patients. Sensitivity and specificity were 100% and 98.7%, respectively. This study indicates that iAAA can be identified with ultrasound, and safely ruled out. In positive ultrasound cases, additional CT imaging might still be warranted.