Liang Yuan

Liang Yuan

Auto-generated profile, based on publicly available information

Liang Yuan

Department of Orthopaedics, Peking University International Hospital, Beijing, China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in BioMed Research International
Verified
Journal Article
Open access
PDF file
LYLiang Yuan
Liang Yuan
BYBin Yang
Bin Yang
XWXiaohua Wang
Xiaohua Wang
BSBin Sun
Bin Sun
KZKe Zhang
Ke Zhang
JYJie Yao
Jie Yao
Purpose. Bony resection is the primary step during total knee arthroplasty. The accuracy of bony resection was highly addressed because it was deemed to have a good relationship with mechanical line. Patient‐specific instruments (PSI) were invented to copy the bony resection references from the preoperative surgical plan during a total knee arthroplasty (TKA); however, the accuracy still remains controversial. This study was aimed at finding out the accuracy of the bony resection during PSI‐assisted TKA. Methods. Forty‐two PSI‐assisted TKAs (based on full‐length leg CT images) were analyzed retrospectively. Resected bones of every patient were given a CT scan, and three‐dimensional radiographs were reconstructed. The thickness of each bony resection was measured with the three‐dimensional radiographs and recorded. The saw blade thickness (1.27 mm) was added to the measurements, and the results represented intraoperative bone resection thickness. A comparison between intraoperative bone resection thickness and preoperatively planned thickness was conducted. The differences were calculated, and the outliers were defined as >3 mm. Results. The distal femoral condyle had the most accurate bone cuts with the smallest difference (median, 1.0 mm at the distal medial femoral condyle and 0.8 mm at the distal lateral femoral condyle) and the least outliers (none at the distal medial femoral condyle and 1 (2.4%) at the distal lateral femoral condyle). The tibial plateau came in second (median difference, 0.8 mm at the medial tibial plateau and 1.4 mm at the lateral tibial plateau; outliers, none at the medial tibial plateau and 1 (2.6%) at the lateral tibial plateau). Regardless of whether the threshold was set to >2 mm (14 (17.9%) at the tibial plateau vs. 12 (14.6%) at the distal femoral condyle, p > 0.05) or >3 mm (1 (1.3%) at the tibial plateau vs. 1 (1.2%) at the distal femoral condyle, p > 0.05), the accuracy of tibial plateau osteotomy was similar to that of the distal femoral condyle. Osteotomy accuracy at the posterior femoral condyle and the anterior femoral condyle were the worst. Outliers were up to 6 (15.0%) at the posterior medial femoral condyle, 5 (12.2%) at the posterior lateral femoral condyle, and 6 (15.8%) at the anterior femoral condyle. The percentages of overcut and undercut tended to 50% in most parts except the lateral tibial plateau. At the lateral tibial plateau, the undercut percentage was twice that of the overcut. Conclusion. The tibial plateau and the distal femoral condyle share a similar accuracy of osteotomy with PSI. PSI have a generally good accuracy during the femur and tibia bone resection in TKA. PSI could be a kind of user‐friendly tool which can simplify TKA with good accuracy. Level of Evidence. This is a Level IV case series with no comparison group.

1 July 2021 in JBJS Case Connector
Verified
Journal Article
Closed access
XWXiaohua Wang
Xiaohua Wang
KZKe Zhang
Ke Zhang
LYLiang Yuan
Liang Yuan
BSBin Sun
Bin Sun
BYBin Yang
Bin Yang
Case: Using a multidisciplinary team approach, a cemented posterior-stabilized total knee arthroplasty was performed using 3-dimensional–printed patient-specific instruments (PSI) in a 34-year-old man with symptomatic end-stage knee osteoarthritis secondary to Klippel-Trénaunay syndrome (KTS). At 1-year follow-up, the patient was able to walk without pain and return to work. Conclusion: Knee arthroplasty is rare in patients with KTS. Compared with traditional instrumentation, PSI provides the benefit of minimal tissue dissection which can be advantageous in patients with altered anatomy such as KTS. Multidisciplinary cooperation is vital in terms of dealing with multiple comorbidities in KTS.