Yushu Wang

Yushu Wang

Auto-generated profile, based on publicly available information

Yushu Wang

Department of Biomedical Engineering, Tufts University, Medford, MA 02155, USA

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 June 2020 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
PDF file
YWYushu Wang
Yushu Wang
Wenwen HuangWenwen Huang
Wenwen Huang
YWYu Wang
Yu Wang
Xuan MuXuan Mu
Xuan Mu
SLShengjie Ling
Shengjie Ling
DKDavid Kaplan
David Kaplan
Significance: The majority of deformable actuators rely on synthetic materials with stimuli-responsive properties to execute the system, limiting their use in vivo. We designed and built a new class of bionic actuator entirely out of biocompatible and biodegradable materials. Stimuli-responsive genetically engineered silk–elastin-like proteins (SELPs) and cellulose nanofibers (CNFs) are combined to fabricate an actuator system that could effectively respond to physical and chemical stimuli. Programmable and reversible deformations in response to the stimuli have been achieved with this actuator. The SELP/CNF actuator provides an option for fields such as in vivo biomedical soft robotics and biomimetic devices where biocompatibility, biodegradability, biomedical signals recognition, and durability are desired.

18 February 2025 in Advanced Materials
Verified
Journal Article
Closed access
YWYushu Wang
Yushu Wang
XQXiaoyan Qin
Xiaoyan Qin
YFYunhao Feng
Yunhao Feng
TZTi Zhang
Ti Zhang
XWXinyu Wang
Xinyu Wang
Chaoyong LiuChaoyong Liu
Chaoyong Liu

7 August 2023 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Open access
YWYushu Wang
Yushu Wang
LLLuhe Li
Luhe Li
YJYue-E. Ji
Yue-E. Ji
TWTao Wang
Tao Wang
YFYinghao Fu
Yinghao Fu
YLYan-Qing Lu
Yan-Qing Lu
Biocompatible and morphable hydrogels capable of multimode reprogrammable, and adaptive shape changes are potentially useful for diverse biomedical applications. However, existing morphable systems often rely on complicated structural designs involving cumbersome and energy-intensive fabrication processes. Here, we report a simple electric-field-activated protein network migration strategy to reversibly program silk-protein hydrogels with controllable and reprogrammable complex shape transformations. The application of a low electric field enables the convergence of net negatively charged protein cross-linking networks toward the anode (isoelectric point plane) due to the pH gradient generated in the process, facilitating the formation of a gradient network structure and systems suitable for three-dimensional shape change. These tunable protein networks can be reprogrammed or permanently fixed by control of the polymorphic transitions. We show that these morphing hydrogels are capable of conformally interfacing with biological tissues by programming the shape changes and a bimorph structure consisting of aligned carbon nanotube multilayers and the silk hydrogels was assembled to illustrate utility as an implantable bioelectronic device for localized low-voltage electrical stimulation of the sciatic nerve in a rabbit.

31 January 2025 in Advanced Functional Materials
Verified
Journal Article
Closed access
YWYushu Wang
Yushu Wang
KNKristo Nuutila
Kristo Nuutila
ACAnders H Carlsson
Anders H Carlsson
SCSean Christy
Sean Christy
DLDavid Larson
David Larson
DKDavid Kaplan
David Kaplan

7 August 2026 in Science Advances
Verified
Journal Article
Open access
PLPenghao Liu
Penghao Liu
XWXinyu Wang
Xinyu Wang
YLYanchun Liu
Yanchun Liu
ZXZhuofan Xu
Zhuofan Xu
YHYana He
Yana He
WDWanru Duan
Wanru Duan
Spinal cord stimulation has emerged as a promising therapeutic strategy for spinal cord injury (SCI), yet conventional electronic implants remain limited by surgical risk and long-term safety concerns. We introduce a biodegradable piezoelectric cryogel (Piezo Gel) that enables programmable electro-neuromodulation without implanted electronics. Engineered to replicate spinal column mechanics, Piezo Gel converts physiological motion into localized bioelectrical signals; externally applied ultrasound (US) further amplifies this output, enabling non-invasive, on-demand neuromodulation. In acute severe SCI rats, US-activated Piezo Gel markedly improved locomotor recovery, elevated Basso–Beattie–Bresnahan (BBB) scores, and promoted bladder functional remodeling. In mild contusion rats, a phase-adaptive neuromodulation strategy shifted from US-triggered stimulation during the acute immobilization phase to motion-driven stimulation during subacute rehabilitation, dynamically matching the evolving pathological microenvironment after SCI. This sequential electrostimulation paradigm produced marked restoration of coordinated gait. Together, these findings establish an electronic-free platform for programmable electro-neuromodulation that integrates US and physiological motion, offering a clinically translatable strategy for SCI repair.