José Ramón Jiménez

José Ramón Jiménez

Auto-generated profile, based on publicly available information

José Ramón Jiménez

Departamento de Óptica, Facultad de Ciencias, Universidad de Granada, Granada 18071, Spain

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2006 in Journal of Refractive Surgery
Verified
Journal Article
Closed access
PDF file
JJJosé Ramón Jiménez
José Ramón Jiménez
CVCesar Villa
Cesar Villa
RARosario González Anera
Rosario González Anera
RGRamón Gutiérrez
Ramón Gutiérrez
LBLuis Jiménez del Barco
Luis Jiménez del Barco
PURPOSE: To analyze binocular visual function after LASIK. METHODS: Eye aberrometry and corneal topography was obtained for both eyes in 68 patients (136 eyes). To evaluate visual performance, monocular and binocular contrast sensitivity function and disturbance index for quantifying halos were measured. Tests were performed under mesopic conditions. RESULTS: Binocular summation and disturbance index diminished significantly (P<.0001) after LASIK with increasing interocular differences in corneal and eye aberrations. Binocular visual deterioration was greater than monocular deterioration for contrast sensitivity function and disturbance index. CONCLUSIONS: Binocular function deteriorates more than monocular function after LASIK. This deterioration increases as the interocular differences in aberrations and corneal shape increase. Improvements in ablation algorithms should minimize these interocular differences. [J Refract Surg. 2006;22:679-688.]

1 March 2008 in Optometry and Vision Science
Verified
Journal Article
Closed access
JJJosé R. Jiménez
José R. Jiménez
José  J. Castro-TorresJosé J. Castro-Torres
José J. Castro-Torres
RJRaimundo Jiménez
Raimundo Jiménez
EHEnrique Hita
Enrique Hita

1 March 2003 in American Journal of Ophthalmology
Verified
Journal Article
Closed access
JCJos Ramn Jimnez Cuesta
Jos Ramn Jimnez Cuesta
RARosario Gonzalez Anera
Rosario Gonzalez Anera
RJRaimundo Jimnez
Raimundo Jimnez
CSCarlos Salas
Carlos Salas

1 January 2003 in Journal of Biomedical Optics
Verified
Journal Article
Closed access
PDF file
RGRamón GutiérRez
Ramón GutiérRez
JJJosé Ramón JiménEz
José Ramón JiménEz
CVCésAr Villa
CésAr Villa
JVJuan Antonio Valverde
Juan Antonio Valverde
RARosario GonzálEz Anera
Rosario GonzálEz Anera
We present a simple device (called a halometer) to detect and quantify the phenomenon of halos after certain surgical procedures, such as refractive surgery. The task of the subject consists basically of discriminating, after dark adaptation, a small light source around a central high-luminance stimulus. The device, which is connected to a computer, provides a disturbance index to measure the effect of halos on the observer’s vision. Tested with normal subjects and patients after LASIK (laser in situ keratomileusis) surgery, this apparatus proved sufficiently sensitive to quantify the halos in subjects who had undergone surgery. © 2003 Society of Photo-Optical Instrumentation Engineers.

15 March 2003 in Optics Letters
Verified
Journal Article
Closed access
PDF file
RARosario G. Anera
Rosario G. Anera
JJJose R. Jiménez
Jose R. Jiménez
LBLuis Jiménez del Barco
Luis Jiménez del Barco
EHEnrique Hita
Enrique Hita
We tested the effects on laser ablation of reflection losses and nonnormal incidence on the anterior cornea. We measured presurgical and postsurgical corneal asphericity in 94 myopic eyes, comparing it with the corneal asphericity predicted by the Munnerlyn formula, modified or not, with an adjustment factor that takes into account the two effects mentioned above. The predictive power of the experimental results was stronger when we considered the adjustment factor. We propose to modify ablation algorithms by taking this adjustment factor into account, especially in customized corneal ablation, which needs high accuracy for correcting eye aberrations.

1 January 2003 in Journal of Refractive Surgery
Verified
Journal Article
Closed access
JJJosé R Jiménez
José R Jiménez
RARosario G Anera
Rosario G Anera
LBLuis Jiménez del Barco
Luis Jiménez del Barco
PURPOSE: To determine the exact theoretical asphericity after refractive surgery when the parabolic approximation of the Munnerlyn formula is utilized. METHOD: From a least-square analysis and considering the conicoid model for anterior cornea, we calculated the final asphericity (p '-factor) from the preoperative asphericity and the radii before and after surgery. RESULTS: The final p-factor is given by p'=p(R'3/R3); R is the final radius of curvature; R is the preoperative radius; and p is the preoperative p'-factor. CONCLUSIONS: This equation for postoperative asphericity may be useful in studying the influence on asphericity of different surgical variables. It allows comparisons of real asphericity with the asphericity that should theoretically result. It also explains the increased spherical aberration after refractive surgery and the deterioration of retinal image quality that some authors have found experimentally. [J Refract Surg 2003;19:65-69]