José  J. Castro-Torres

Dr. José J. Castro-Torres

Laboratory of Vision Sciences and Applications, Department of Optics, University of Granada, 18010 Granada, Spain
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2018 in Accident Analysis & Prevention
Verified
Journal Article
Closed access
COCarolina Ortiz
Carolina Ortiz
SOSonia Ortiz-Peregrina
Sonia Ortiz-Peregrina
José  J. Castro-TorresJosé J. Castro-Torres
José J. Castro-Torres
Miriam Casares-LópezMiriam Casares-López
Miriam Casares-López
CSC. Salas
C. Salas

1 March 2008 in Optometry and Vision Science
Verified
Journal Article
Closed access
JJJosé R. Jiménez
José R. Jiménez
José  J. Castro-TorresJosé J. Castro-Torres
José J. Castro-Torres
RJRaimundo Jiménez
Raimundo Jiménez
EHEnrique Hita
Enrique Hita

SOSonia Ortiz-Peregrina
Sonia Ortiz-Peregrina
COCarolina Ortiz
Carolina Ortiz
Miriam Casares-LópezMiriam Casares-López
Miriam Casares-López
José  J. Castro-TorresJosé J. Castro-Torres
José J. Castro-Torres
LBLuis Jiménez del Barco
Luis Jiménez del Barco
RARosario G. Anera
Rosario G. Anera
Aging leads to impaired visual function, which can affect driving—a very visually demanding task—and has a direct impact on an individual’s quality of life if their license is withdrawn. This study examined the associations between age-related vision changes and simulated driving performance. To this end, we attempted to determine the most significant visual parameters in terms of evaluating elderly drivers’ eyesight. Twenty-one younger drivers (aged 25–40) were compared to 21 older drivers (aged 56–71). Study participants were assessed for visual acuity, contrast sensitivity, halos, and intraocular straylight, which causes veiling luminance on the retina and degrades vision. Driving performance was evaluated using a driving simulator. The relationships between simulated driving performance and the visual parameters tested were examined with correlation analyses and linear regression models. Older drivers presented impairment in most visual parameters (p < 0.05), with straylight being the most significantly affected (we also measured the associated effect size). Older drivers performed significantly worse (p < 0.05) in the simulator test, with a markedly lower performance in lane stability. The results of the multiple linear regression model evidenced that intraocular straylight is the best visual parameter for predicting simulated driving performance (R2 = 0.513). Older drivers have shown significantly poorer results in several aspects of visual function, as well as difficulties in driving simulator performance. Our results suggest that the non-standardized straylight evaluation could be significant in driver assessments, especially at the onset of age-related vision changes.

1 January 2011 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
José  J. Castro-TorresJosé J. Castro-Torres
José J. Castro-Torres
JJJosé R. JiménEz
José R. JiménEz
COCarolina Ortiz
Carolina Ortiz
AAAixa Alarcón
Aixa Alarcón
RARosario González Anera
Rosario González Anera
In the last decade, the use and development of objective optical devices, such as aberrometers and double-pass devices, have expanded to evaluate the optical quality of the human eye. 1, 2, 3, 4, 5 With these devices, the aim is to achieve an objective evaluation of the observer's visual state, spending the least time possible in taking the data. This time savings is a great advantage in clinics, where time spent per patient is limited; also, for older patients, speed of examination avoids unnecessary fatigue in the observer. However, these optical devices were previously large and also costly, sometimes prohibitively so. Without these devices, the visual examination of the subject would be limited to the usual psychophysical tests as well as the study of the refractive state of the subject. Therefore, other subjective tests are needed that require the cooperation of the patient to characterize the visual performance of the subject. The discrimination capacity of the subject is an important visual function for this purpose, allowing us to evaluate the real state of vision of the subject and providing an easy tool for detecting potential visual dysfunctions. For these reasons, a new visual test for quantifying discrimination capacity was developed that needs no specific hardware, is free of charge, and is becoming an accessible and easy tool for clinical applications compared to former complex optical devices. On the other hand, the development of simple visual tests that evaluate visual function is an important task for the study, monitoring, and early diagnosis of different visual pathologies that develop asymptomatically to advanced stages of pathology, such as age-related macular degeneration (ARMD), and that could go unnoticed if not adequately tested. In this study, we check the visual test developed for quantifying discrimination capacity in subjects with different ocular pathologies and seek to determine whether these ocular pathologies, which affect the retinal-image quality, cause any deterioration in the discrimination capacity and, consequently, in visual performance.

1 August 2011 in Journal of Refractive Surgery
Verified
Journal Article
Closed access
RARosario G. Anera
Rosario G. Anera
José  J. Castro-TorresJosé J. Castro-Torres
José J. Castro-Torres
JJJosé R. Jiménez
José R. Jiménez
CVCésar Villa
César Villa
AAAixa Alarcón
Aixa Alarcón
PURPOSE: To determine whether the eye’s optical quality is correlated to the visual discrimination capacity of patients treated with LASIK using two different ablation algorithms. METHODS: Visual discrimination was evaluated by the disturbance index under low illumination (Halo v1.0 software, Laboratory of Vision Sciences and Applications) in two groups of patients who underwent LASIK with two different ablation algorithms using the Allegretto Wave Eye-Q 400 Hz laser (WaveLight AG). In the first group (standard group; 30 eyes), corneal ablations were performed with the standard algorithm (preoperative spherical equivalent refraction −3.20±1.70 diopters [D]). In the second group (Q-optimized group; 38 eyes; spherical equivalent refraction −3.40±1.90 D), the ablations were made with the Q-optimized (F-CAT) algorithm. Optical quality of the eye was calculated by the Strehl ratio measured with a double-pass device (OQAS, Visiometrics SL). RESULTS: After LASIK, both the Strehl ratio as well as visual discrimination capacity diminished in both groups, although the changes were significantly greater in the standard group than in the Q-optimized group. CONCLUSIONS: A high correlation was found between the Strehl ratio and the disturbance index in patients who underwent LASIK, regardless of the ablation algorithm applied. Optical and visual deterioration were greater after standard ablation.

1 July 2013 in Applied Ergonomics
Verified
Journal Article
Closed access
COCarolina Ortiz
Carolina Ortiz
José  J. Castro-TorresJosé J. Castro-Torres
José J. Castro-Torres
AAAixa Alarcón
Aixa Alarcón
MSMargarita Soler
Margarita Soler
RARosario G. Anera
Rosario G. Anera