Peter Phillips

Peter Phillips

Auto-generated profile, based on publicly available information

Peter Phillips

Health and Medical Sciences Group, University of Cumbria, Lancaster, UK

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2007 in American Journal of Roentgenology
Verified
Journal Article
Closed access
PBPatrick C. Brennan
Patrick C. Brennan
MMMark F McEntee
Mark F McEntee
MEMichael Evanoff
Michael Evanoff
PPPeter Phillips
Peter Phillips
WOWilliam T. O'Connor
William T. O'Connor
DMDavid J. Manning
David J. Manning
OBJECTIVE. The aim of the work was to establish optimum ambient light conditions for viewing radiologic images of the wrist on liquid crystal display monitors.MATERIALS AND METHODS. Five ambient light levels were investigated: 480, 100, 40, 25, and 7 lux. Seventy-nine experienced radiologists were asked to examine 30 posteroanterior wrist images and decide whether a fracture was present. All images were displayed on liquid crystal display monitors. Receiver operating characteristic analysis was performed, and the numbers of false-positive and false-negative findings were recorded.RESULTS. For all the radiologists, greater area under the receiver operating characteristic curve and lower numbers of false-positive and false-negative findings were recorded at 40 and 25 lux compared with 480 and 100 lux. At 7 lux, the results were generally similar to those at 480 and 100 lux. The experience and knowledge of radiologists specializing in imaging of musculoskeletal trauma appeared to compensate in part for inapp...

1 December 2014 in Radiology
Verified
Journal Article
Closed access
SMSusan Mallett
Susan Mallett
PPPeter Phillips
Peter Phillips
TFThomas R. Fanshawe
Thomas R. Fanshawe
EHEmma Helbren
Emma Helbren
DBDarren Boone
Darren Boone
SHSteve Halligan
Steve Halligan
To identify and compare key stages of the visual process in experienced and inexperienced readers and to examine how these processes are used to search a moving three-dimensional ( 3D three-dimensional ) image and their relationship to false-negative errors. Institutional review board research ethics approval was granted to use anonymized computed tomographic (CT) colonographic data from previous studies and to obtain eye-tracking data from volunteers. Sixty-five radiologists (27 experienced, 38 inexperienced) interpreted 23 endoluminal 3D three-dimensional CT colonographic videos. Eye movements were recorded by using eye tracking with a desk-mounted tracker. Readers indicated when they saw a polyp by clicking a computer mouse. Polyp location and boundary on each video frame were quantified and gaze data were related to the polyp boundary for each individual reader and case. Predefined metrics were quantified and used to describe and compare visual search patterns between experienced and inexperienced readers by using multilevel modeling. Time to first pursuit was significantly shorter in experienced readers (hazard ratio, 1.22 [95% confidence interval: 1.04, 1.44]; P = .017) but other metrics were not significantly different. Regardless of expertise, metrics such as assessment, identification period, and pursuit times were extended in videos where polyps were visible on screen for longer periods of time. In 97% (760 of 787) of observations, readers correctly pursued polyps. Experienced readers had shorter time to first eye pursuit, but many other characteristics of eye tracking were similar between experienced and inexperienced readers. Readers pursued polyps in 97% of observations, which indicated that errors during interpretation of 3D three-dimensional CT colonography in this study occurred in either the discovery or the recognition phase, but rarely in the scanning phase of radiologic image inspection.

1 January 2006 in Experimental Psychology
Verified
Journal Article
Closed access
LBLinden John Ball
Linden John Ball
PPPeter Phillips
Peter Phillips
CWCaroline N. Wade
Caroline N. Wade
JQJeremy D. Quayle
Jeremy D. Quayle
Studies of syllogistic reasoning have demonstrated a nonlogical tendency for people to endorse more believable conclusions than unbelievable ones. This belief bias effect is more dominant on invalid syllogisms than valid ones, giving rise to a logic by belief interaction. We report an experiment in which participants’ eye movements were recorded in order to provide insights into the nature and time course of the reasoning processes associated with manipulations of conclusion validity and believability. Our main dependent measure was people’s inspection times for syllogistic premises, and we tested predictions deriving from three contemporary mental-models accounts of the logic by belief interaction. Results supported recent “selective processing” theories of belief bias (e.g., Evans, 2000 ; Klauer, Musch, & Naumer, 2000 ), which assume that the believability of a conclusion biases model construction processes, rather than biasing the search for falsifying models (e.g., Oakhill & Johnson-Laird, 1985 ) or a response stage of reasoning arising from subjective uncertainty (e.g., Quayle & Ball, 2000 ). We conclude by suggesting that the eye-movement analyses in reasoning research may provide a useful adjunct to other process-tracing techniques such as verbal protocol analysis.

10 March 2007
Verified
Book Chapter
Closed access
PDF file
APAlex Poole
Alex Poole
LBLinden J Ball
Linden J Ball
PPPeter Phillips
Peter Phillips

29 March 2014 in British Journal of Radiology
Verified
Journal Article
Closed access
EHE Helbren
E Helbren
SHS Halligan
S Halligan
PPP Phillips
P Phillips
DBD Boone
D Boone
TFT R Fanshawe
T R Fanshawe
SMS Mallett
S Mallett
Objective: Eye tracking in three dimensions is novel, but established descriptors derived from two-dimensional (2D) studies are not transferable. We aimed to develop metrics suitable for statistical comparison of eye-tracking data obtained from readers of three-dimensional (3D) “virtual” medical imaging, using CT colonography (CTC) as a typical example. Methods: Ten experienced radiologists were eye tracked while observing eight 3D endoluminal CTC videos. Subsequently, we developed metrics that described their visual search patterns based on concepts derived from 2D gaze studies. Statistical methods were developed to allow analysis of the metrics. Results: Eye tracking was possible for all readers. Visual dwell on the moving region of interest (ROI) was defined as pursuit of the moving object across multiple frames. Using this concept of pursuit, five categories of metrics were defined that allowed characterization of reader gaze behaviour. These were time to first pursuit, identification and assessment time, pursuit duration, ROI size and pursuit frequency. Additional subcategories allowed us to further characterize visual search between readers in the test population. Conclusion: We propose metrics for the characterization of visual search of 3D moving medical images. These metrics can be used to compare readers' visual search patterns and provide a reproducible framework for the analysis of gaze tracking in the 3D environment. Advances in knowledge: This article describes a novel set of metrics that can be used to describe gaze behaviour when eye tracking readers during interpretation of 3D medical images. These metrics build on those established for 2D eye tracking and are applicable to increasingly common 3D medical image displays.

1 June 2013 in Radiology
Verified
Journal Article
Closed access
PPPeter Phillips
Peter Phillips
DBDarren Boone
Darren Boone
SMSusan Mallett
Susan Mallett
STStuart A. Taylor
Stuart A. Taylor
DADouglas G. Altman
Douglas G. Altman
SHSteve Halligan
Steve Halligan
Purpose: To develop an eye-tracking method applicable to three-dimensional (3D) images, where the abnormality is both moving and changing in size. Materials and Methods: Research ethics committee approval was granted to record eye-tracking data from six inexperienced readers who inspected eight short (<30 seconds) endoluminal fly-through videos extracted from computed tomographic (CT) colonography examinations. Cases included truepositive and false-positive polyp detections from a previous study (polyp diameters, 5-25 mm). Eye tracking was performed with a desk-mounted tracker, and readers indicated when they saw a polyp with a mouse click. The polyp location on each video frame was quantified subsequently by using a circular mask. Gaze data related to each video frame were calculated relative to the visible polyp boundary and used to identify eye movements that pursue a polyp target as it changes size and position during fly-through. Gaze data were then related to positive polyp detections by readers. Results: Tracking eye gaze on moving 3D images was technically feasible. Gaze was successfully classified by using pursuit analysis, and pursuit-based gaze metrics were able to help discriminate different reader search behaviors and methods of allocating visual attention during polyp identification. Of a total of 16 perceptual errors, 15 were recognition errors. There was only one visual search error. The largest polyp (25 mm) was seen but not recognized by five of six readers. Conclusion: Tracking a reader's gaze during endoluminal interpretation of 3D data sets is technically feasible and can be described with pursuit-based metrics. Perceptual errors can be classified into visual search errors and recognition errors. Recognition errors are more frequent in inexperienced readers.