Abdul Aziz Hulleck

Abdul Aziz Hulleck

Auto-generated profile, based on publicly available information

Abdul Aziz Hulleck

Department of Mechanical Engineering, Khalifa University, Abu Dhabi, UAE

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 October 2023 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
RKRateb Katmah
Rateb Katmah
ASAamna Al Shehhi
Aamna Al Shehhi
HJHerbert Jelinek
Herbert Jelinek
AHAbdul Aziz Hulleck
Abdul Aziz Hulleck
KKKinda Khalaf
Kinda Khalaf
Background: Neurological diseases are a leading cause of disability and mortality. Gait, or human walking, is a significant predictor of quality of life, morbidity, and mortality. Gait patterns and other kinematic, kinetic, and balance gait features are accurate and powerful diagnostic and prognostic tools. Objective: This review article focuses on the applicability of gait analysis using fusion techniques and artificial intelligence (AI) models. The aim is to examine the significance of mixing several types of wearable and non-wearable sensor data and the impact of this combination on the performance of AI models. Method: In this systematic review, 66 studies using more than two modalities to record and analyze gait were identified. 40 studies incorporated multiple gait analysis modalities without the use of artificial intelligence to extract gait features such as kinematic, kinetic, margin of stability, temporal, and spatial gait parameters, as well as cerebral activity. Similarly, 26 studies analyzed gait data using multimodal fusion sensors and AI algorithms. Results: The research summarized here demonstrates that the quality of gait analysis and the effectiveness of AI models can both benefit from the integration of data from many sensors. Meanwhile, the utilization of EMG signals in fusion data is especially advantageous. Conclusion: The findings of this review suggest that a smart, portable, wearable-based gait and balance assessment system can be developed using multimodal sensing of the most cutting-edge, clinically relevant tools and technology available. The information presented in this article may serve as a vital springboard for such development.

22 April 2024 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
AHAbdul Aziz Hulleck
Abdul Aziz Hulleck
AAAamna AlShehhi
Aamna AlShehhi
MEMarwan El-Rich
Marwan El-Rich
RKRaviha Khan
Raviha Khan
RKRateb Katmah
Rateb Katmah
KKKinda Khalaf
Kinda Khalaf
Evaluation of human gait through smartphone-based pose estimation algorithms provides an attractive alternative to costly lab-bound instrumented assessment and offers a paradigm shift with real time gait capture for clinical assessment. Systems based on smart phones, such as OpenPose and BlazePose have demonstrated potential for virtual motion assessment but still lack the accuracy and repeatability standards required for clinical viability. Seq2seq architecture offers an alternative solution to conventional deep learning techniques for predicting joint kinematics during gait. This study introduces a novel enhancement to the low-powered BlazePose algorithm by incorporating a Seq2seq autoencoder deep learning model. To ensure data accuracy and reliability, synchronized motion capture involving an RGB camera and ten Vicon cameras were employed across three distinct self-selected walking speeds. This investigation presents a groundbreaking avenue for remote gait assessment, harnessing the potential of Seq2seq architectures inspired by natural language processing (NLP) to enhance pose estimation accuracy. When comparing BlazePose alone to the combination of BlazePose and 1D convolution Long Short-term Memory Network (1D-LSTM), Gated Recurrent Unit (GRU) and Long Short-Term Memory (LSTM), the average mean absolute errors decreased from 13.4° to 5.3° for fast gait, from 16.3° to 7.5° for normal gait, and from 15.5° to 7.5° for slow gait at the left ankle joint angle respectively. The strategic utilization of synchronized data and rigorous testing methodologies further bolsters the robustness and credibility of these findings.

16 August 2023 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
TLTao Liu
Tao Liu
AHAbdul Aziz Hulleck
Abdul Aziz Hulleck
MEMarwan El-Rich
Marwan El-Rich

27 January 2025 in Computers in Biology and Medicine
Verified
Journal Article
Open access
AHAbdul Aziz Vaqar Hulleck
Abdul Aziz Vaqar Hulleck
MAMuhammad Abdullah
Muhammad Abdullah
AAAbdelSalam Tareq Alkhalaileh
AbdelSalam Tareq Alkhalaileh
TLTao Liu
Tao Liu
DMDhanya Menoth Mohan
Dhanya Menoth Mohan
MEMarwan El-Rich
Marwan El-Rich
Musculoskeletal modeling based on inverse dynamics provides a cost-effective non-invasive means for calculating intersegmental joint reaction forces and moments, solely relying on kinematic data, easily obtained from smart wearables. On the other hand, the accuracy and precision of such models strongly hinge upon the selected scaling methodology tailored to subject-specific data. This study investigates the impact of upper body mass distribution on internal and external kinetics computed using a comprehensive musculoskeletal model during level walking in both normal weight and obese individuals. Human motion data was collected using seventeen body worn inertial measuring units for nineteen (19) healthy subjects. The results indicate that variations in segmental masses and centers of mass, resulting from diverse mass scaling techniques, significantly affect ground reaction force estimations in obese subjects, particularly in the vertical component, with a root mean square error (RMSE) of 54.7 ± 23.8 %BW; followed by 12.3 ± 8.0 %BW (medio-lateral); and 6.2 ± 3.2 %BW (antero-posterior). The vertical component of hip, knee, and ankle joint reaction forces also exhibit sensitivity to personalized mass distribution variations. Importantly, the degree of deviation in model predictions increases with body mass index. Statistical analysis using single sample Wilcoxon-Signed Rank test for non-normal data and t-test for normal data, revealed significant differences (p < 0.05) in the computed errors in kinetic parameters between the two scaling approaches. The body shape-based scaling approach significantly impacts musculoskeletal modeling in clinical applications where the upper body mass distribution is crucial, such as in spinal deformities, obesity, and low back pain. This approach accounts for the body shape inherent variability within the same BMI category and enhances the predicted joint kinetics.

21 October 2024 in TechRxiv
Verified
Preprint
Open access
AHAbdul Aziz Hulleck
Abdul Aziz Hulleck
MAMuhammad Abdullah
Muhammad Abdullah
MRMarwan El Rich
Marwan El Rich
RKRateb Katmah
Rateb Katmah
KKKinda Khalaf
Kinda Khalaf
AAAamna AlShehhi
Aamna AlShehhi
Quantitative gait analysis is vital for understanding human movement, with vertical Ground Reaction Forces (vGRFs) being a key metric. Traditional methods to measure vGRFs, such as force plates and treadmills, are bulky, expensive, and may not reflect natural gait patterns. This study introduces a physics informed deep learning framework that uses ankle position data in the sagittal plane to predict vGRFs from marker-based motion capture. The framework includes sequence-to-sequence models such as LSTM, GRU, and one-dimensional convolutional layers with LSTM, using both data-driven (Seq2Seq) and physics-based (Physics-Informed Neural Network, PiNN). Internal dataset results showed that Seq2Seq outperformed PiNN on the left limb, while PiNN showed better performance on the right limb in some configurations. Both models experienced increased RMSE on external datasets, highlighting challenges in generalization. Spearman correlation analysis indicated PiNN had a stronger relationship with measured vGRFs in the internal dataset, but Seq2Seq demonstrated better generalization. RMSE values ranged from 11.55% to 16.00% body weight (BW) for Seq2Seq models and 11.55% to 17.85% BW for PiNN. Although Seq2Seq models had greater variability, they closely matched measured values in certain configurations. These findings suggest PiNN models effectively capture vGRF patterns, but further refinement and training on diverse datasets are needed to improve generalization. Future research should focus on incorporating additional physical constraints to enhance model robustness in real-world scenarios.

8 November 2024
Verified
Conference Paper
Open access
MAMuhammad Abdullah
Muhammad Abdullah
AHAbdul Aziz Hulleck
Abdul Aziz Hulleck
DIDominika Ignasiak
Dominika Ignasiak
TLTao Liu
Tao Liu
NANavid Arjmand
Navid Arjmand
MEMarwan El-Rich
Marwan El-Rich
Accurate modeling of musculoskeletal (MSK) dynamics tailored to individual patients is crucial for evaluating adult spinal deformities, especially in the thoracic region. This research explores the impact of personalized upper-body mass distribution on predictions of spinal loads using both rigid and flexible thorax models in neutral standing and forward flexion postures. Two MSK models were employed: a rigid thorax model with thoracic spinal discs treated as rigid joints, and a flexible thorax model with thoracic discs modeled as spherical joints allowing three degrees of freedom. These models incorporated constant percentage base (CPB) and body shape-based (BSB) mass distributions, resulting in four configurations: Rigid-CPB, Rigid-BSB, Flexible-CPB, and Flexible-BSB. In neutral standing, the root means square error (RMSE) averaged 16.96% BW in the anteroposterior direction and 24.79% BW in the proximodistal direction between the Rigid-CPB and Flexible-BSB models. These errors increased during forward flexion to 43.72% BW and 84.86% BW, respectively. In the mediolateral direction, RMSE was 6.69% BW during forward flexion and 0.02% BW during neutral standing. The normalized RMSE (nRMSE) averaged below 8.5% in both postures. This study underscores the effectiveness of the Flexible-BSB model in simulating intricate spinal deformities, offering valuable biomechanical insights. It emphasizes the critical role of personalized mass distribution and thoracic flexibility in improving the precision of MSK simulations for clinical applications.