23 November 2020 in The International Journal of Cardiovascular Imaging
Three dimensional speckle tracking echocardiography (3D-STE) is a novel modality for the assessment of left ventricular strain (LVS). The aim of our study is to provide single vendor normative strain values measured with 3D-STE in healthy adult caucasians. One hundred fifty-five healthy subjects aged 20 to 72 years (≥ 28 subjects per decile) were prospectively included and examined with 2D and 3D transthoracic echocardiography. In 105 both 3D and 2D-STE were feasible (71%, mean age 44 ± 14 years, 51% female). Mean 3D tangential strain (3D-TS) was − 32 ± 2.9%. 3D global longitudinal strain (3D-GLS) demonstrated a significant but not very strong correlation with 2D-GLS values (− 19.7 ± 1.8% vs − 20.4 ± 2.2%, r = 0.462, p < 0.001). No gender difference was observed in 3D strain parameters. 3D-GLS decreased with increasing age stratum (p = 0.024). LVEF was associated with 3D-TS and 3D-GLS (r = − 0.819, p ≤ 0.001 for 3D-TS, p = − 0.477, r < 0.001, p = 0.001 for 3D-GLS). In this single vendor study age and gender-specific normative LV 3D-TS values were reported for healthy adult caucasians. In a significant proportion of the subjects 3D-STE was not feasible, but when feasible, 3D-STE shows excellent association with LVEF, and is therefore a promising novel modality for the assessment of the myocardial function, provided that issues of limited feasibility and temporal resolution are addressed.
6 April 2022 in European Heart Journal Open
To explore whether left atrial (LA) strain with speckle tracking echocardiography (STE) can contribute to prognostication in patients with congenital aortic stenosis (CAS). In this prospective study, consecutive outpatients with stable CAS and healthy adults were enrolled between 2011 and 2015. Left atrial function was analysed with STE using Tomtec software. Associations between LA strain (LAS) measurements and primary composite outcome (any adverse cardiovascular event, hospitalization, or re-intervention) and secondary outcome (re-interventions) were assessed with Cox regression analysis. In total, 98 patients with CAS (mean age: 35.0 ± 11.9 year, female: 59.2%) and 121 controls (age: 43.9 ± 13.8 year, female: 55.4%) were included. The majority of patients were in NYHA class I: 97 (99%) at baseline. At baseline, LA conduit strain (LAS-cd) and strain rate (LASR-cd) were significantly lower in patients than in controls when corrected for age and sex (−18.1 ± 8.7 vs. −23.5 ± 9.9%, P = 0.001 and −0.73 ± 0.31 vs. −1.02 ± 0.43/s, P < 0.001). During a median follow-up of 6.4 years (5.7–7.1), the primary composite outcome occurred in 48 (39.6%) patients. Kaplan–Meier analysis showed that decreased LAS-cd (<21%) was associated with a higher occurrence of the primary outcome (log-rank: P = 0.008). Depressed LAS-cd and LASR-cd were both associated with the primary composite outcome [univariable hazard ratio (HR) = 0.64(0.46–0.88), P = 0.005 and HR = 0.68(0.55–0.83), P < 0.001, respectively]; adjusted HR (for LAS-cd and LASR-cd, respectively): 0.31(0.09–1.04), P = 0.06 and 0.49(0.26–0.89), P = 0.02. Impairment in LA conduit function assessed with STE carries prognostic value in patients with CAS and can be implemented in clinical management.
15 March 2021 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
High-frame-rate (HFR) echo-particle image velocimetry (echoPIV) is a promising tool for measuring intracardiac blood flow dynamics. In this study, we investigate the optimal ultrasound contrast agent (UCA: SonoVue) infusion rate and acoustic output to use for HFR echoPIV (PRF = 4900 Hz) in the left ventricle (LV) of patients. Three infusion rates (0.3, 0.6, and 1.2 ml/min) and five acoustic output amplitudes (by varying transmit voltage: 5, 10, 15, 20, and 30 V-corresponding to mechanical indices of 0.01, 0.02, 0.03, 0.04, and 0.06 at 60-mm depth) were tested in 20 patients admitted for symptoms of heart failure. We assess the accuracy of HFR echoPIV against pulsed-wave Doppler acquisitions obtained for mitral inflow and aortic outflow. In terms of image quality, the 1.2-ml/min infusion rate provided the highest contrast-to-background ratio (CBR) (3-dB improvement over 0.3 ml/min). The highest acoustic output tested resulted in the lowest CBR. Increased acoustic output also resulted in increased microbubble disruption. For the echoPIV results, the 1.2-ml/min infusion rate provided the best vector quality and accuracy; mid-range acoustic outputs (corresponding to 15-20-V transmit voltages) provided the best agreement with the pulsed-wave Doppler. Overall, the highest infusion rate (1.2 ml/min) and mid-range acoustic output amplitudes provided the best image quality and echoPIV results.
1 January 2019 in Brazilian Journal of Cardiovascular Surgery
20 December 2023 in The International Journal of Cardiovascular Imaging