Владимир Михайлович Попов

Владимир Михайлович Попов

Auto-generated profile, based on publicly available information

Владимир Михайлович Попов

Rostov Nuclear Power Plant – a branch of Rosenergoatom Concern JSC

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2023 in Техника и технологии в животноводстве
Verified
Journal Article
Closed access
FUFederal State Budgetary Educational Institution of Higher Education «South Ural State Agrarian University»
Federal State Budgetary Educational Institution of Higher Education «South Ural State Agrarian University»
VAV.A. Afonkina
V.A. Afonkina
VPV.M. Popov
V.M. Popov
VLV.N. Levinsky
V.N. Levinsky
AMA.V. Medvedev
A.V. Medvedev
Russian dairy starter cultures are raw and functional product with a high added value. The cost reduction issues at the product's quality maintaining are an actual task. The developed prototype of a tray drying installation's description with film electric heaters (design version) using is given; the basic version for comparative analysis is the XTDQ-101-5A dryer, where stainless steel ribbed tubes as heaters are used. The compared samples' technical parameters are shown, the analysis of which shows their similarity in design-and-technological features, in particular, in the way of the product's place on trays and the loaded product's volume. Also, the comparative analysis demonstrates the differences, the main of which are heating elements' different types using and, as a result, the automatic control systems' different organization for the drying process. It is noted that a highquality product can be obtained both in the basic and in the design version of the drying installation, had selected previously, taking into account the drying object's characteristics, the most gentle mode of operation for it. In this regard, a calculation according to the methodology of the feasibility study of the development introduced into the production sphere is proposed. The methodology involves costs' calculating of the dryer version design's manufacturing, so as the operating costs of the compared samples on drying dairy starter cultures' example calculating. The final economic effect in the form of the difference in the reduced costs (234696,77 rubles per year), the project option in relation to the base profitability (31,7% higher) and the payback period (for the base option - 2 months, for the project - 1 month) is shown.

21 June 2023 in Global Nuclear Safety
Verified
Journal Article
Open access
PDF file
EAE. A. Abidova
E. A. Abidova
PPP. V. Povarov
P. V. Povarov
VPV. M. Popov
V. M. Popov
OPO. Yu. Pugacheva
O. Yu. Pugacheva
VSV. Ya. Shpicer
V. Ya. Shpicer
The drive of the reactor control and protection system (CPS) is a system of normal operation, important for safety. Malfunctions of the drives of the ARC type CPS are often the initial events for accidents leading to unauthorized downtime. The currently existing standard methods for monitoring the parameters of the CPS do not allow for a reliable assessment of the condition of the drives. In this paper, it is proposed to implement an approach that provides an increase in sensitivity when recognizing the states of the drives of the ARC control system by processing the initial signals, which are vibroacoustic signals registered on the lid of the upper unit of the VVER reactor. A procedure for processing diagnostic signals using singular spectrum analysis is proposed. The proposed approach differs from the known ones by the presence of a scaling procedure, which is implemented by multiplying the eigenvalue matrices by the gankelized matrices of the source data. Due to scaling, the necessary sensitivity increase is provided. The expected increase in sensitivity is based on the fact that the eigenvalues reflect the structure of the signals, which changes significantly under the influence of the defect. The proposed method was used to process vibroacoustic signals registered on the lid of the upper block of the VVER reactor unit. Experimental studies were carried out at the test stand of Izhorskiye Zavody OJSC. The results of processing experimental data indicate a high quality of diagnosis. The hypothesis was clearly confirmed that the difference in the structure of diagnostic signals of serviceable and faulty equipment can manifest itself in the eigenvalues of the gankel signal matrices. The approach proposed in the article to the processing of diagnostic signals is easily amenable to automation and can be implemented in the development of a diagnostic system for the drive of an ARC-type CPS.

21 February 2023 in Global Nuclear Safety
Verified
Journal Article
Open access
PDF file
EAElena A Abidova
Elena A Abidova
ПППрохор Владимирович Поваров
Прохор Владимирович Поваров
ВПВладимир Михайлович Попов
Владимир Михайлович Попов
DPDaria A Prytkova
Daria A Prytkova
ОПОльга Юрьевна Пугачева
Ольга Юрьевна Пугачева
Analytical studies of the results of thermal imaging control using IAS TIK together with the corresponding values of the temperature control results obtained in the standard DGS condition monitoring system were carried out within the framework of R&D for the development of an integrated automated system for thermal imaging control (IAS TIK). Approbation of IAS TIK in NPP conditions was carried out by thermography of standby diesel generator sets of NPP type 12zv40/48+S2445-12. At the same time, the parameters of the diesel engine and the generator were measured using the standard control system. The methodology is proposed that provides an analysis of the uniformity of the operation of diesel cylinders, the condition of the crankshaft bearings, the condition and quality of the generated electricity of the generator, as well as the analysis of the operation of lubrication and cooling systems. The practical application of the technique demonstrates the correspondence between the temperatures measured by the standard system and the IAS TIK. A joint analysis of the results obtained by the standard and developed systems provides an increase in the depth of the diagnostic examination and confirms the information content of the thermographic parameters and the quality of the measurement channels of the standard systems. The parameter values obtained from the analysis of the indicators of the standard control system, recorded at a steady power value, will be used in subsequent diagnostics to establish trends in these parameters