Representative Publications

View All Publications
27 February 2024 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Open access
LZLukas Zezula
Lukas Zezula
MKMatus Kozovsky
Matus Kozovsky
PBPetr Blaha
Petr Blaha
This article presents novel model-based diagnostics of interturn short circuits in permanent magnet synchronous machines that enable estimating fault location and its severity, even during transients. The proposed method utilizes recursive parametric estimation and model comparison approaches cast in a decision-making framework to track motor parameters and fault indicators from a machine's discrete-time model. The discrete-time prototype is derived from an advanced motor model that reflects the stator winding arrangement in a motor's case. The fault detection is then performed by tracking the changes in the estimated probability density function of the electrical parameters, using the Kullback–Leibler divergence. The fault location is subsequently evaluated by performing a recursive comparison of the predefined fault models in the different phases, utilizing a growing-window approach. Ultimately, a parametric estimation algorithm applied to the fault current model allows identifying the fault severity. The diagnostic algorithm has been validated via laboratory experiments, and its capabilities are compared with other approaches enabling severity estimation.

1 January 2016
Verified
Conference Paper
Closed access
MKMatus Kozovsky
Matus Kozovsky
PBPetr Blaha
Petr Blaha
PVPavel Vaclavek
Pavel Vaclavek
Electric motors with more than three phases have many advantages comparing to ordinary three-phase motor. For this reason it is natural to pay attention to them and to work on advanced control methods. Control algorithms development requires to operate with the model of motor. This paper presents the modeling concept of the nine-phase permanent magnet synchronous motor (PMSM) in three times three-phase arrangement fed by nine-phase voltage source inverter (VSI). Magnetic interaction between phases and phase groups had to be taken into account. The paper also provides relationship between model parameters and real motor ones, depending on the windings configuration. It shows the comparison between the simulation and experimental results with real motor. Used method of motor parameters measurement and the subsequent conversion of these parameters into d-q coordinates is clarified in this paper.

3 April 2025 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Open access
LBLudek Buchta
Ludek Buchta
MKMatus Kozovsky
Matus Kozovsky
PBPetr Blaha
Petr Blaha
This article presents an innovative approach to mitigate the harmonic distortion of the phase currents of a permanent magnet synchronous motor (PMSM) controlled by a field-oriented control (FOC) algorithm. The issue of phase current harmonic distortion is often a consequence of the output voltage deformation caused by the nonlinearities of the voltage source inverter (VSI). The relationship between the disturbance voltages of the inverter and the phase currents of the motor is nonlinear. Therefore, we used an artificial neural network (ANN) to identify the compensation voltages. The topology is designed to allow the neural network to solve complex problems with the limited computing resources available on the AURIX TC397 microcontroller. The input vector is assembled from quantities available in the PMSM FOC algorithm. The online learning process based on the backpropagation algorithm is adapted to operate directly on the microcontroller. The proposed strategy with ANN is verified on a real PMSM. The results show the excellent ability of the proposed ANN to suppress the harmonic distortion of the PMSM phase currents without knowledge of the VSI parameters.

1 January 2019 in IFAC-PapersOnLine
Verified
Journal Article
Open access
MKM. Kozovsky
M. Kozovsky
PBP. Blaha
P. Blaha

1 November 2017
Verified
Conference Paper
Closed access
MKMatus Kozovsky
Matus Kozovsky
PBPetr Blaha
Petr Blaha
This paper deals with the nine-phase motor control algorithm development, mainly with its implementation in target hardware using MATLAB Simulink. This environment allows control algorithm design using model based approach and the subsequent automatic conversion of control algorithms into C code using Simulink Embedded coder which is then used in the inverter software. Field oriented control algorithm has been designed and tuned for this motor. Control algorithm has been tuned according to the measured motor parameters in simulations and then fine tuned on a real motor. The inverter control unit is based on AURIX Tricore microcontroller TC275. The code generation in Simulink has many settings. This paper analyses computational time depending on these settings. Potential problems with floating point math functions are outlined. Automatic code generation proves to be quick and easy tool for replacement of control algorithms or for fast control algorithm adaptation to different hardware.