1 May 2011 in Applied Thermal Engineering
3 November 2023 in Sustainable Energy Technologies and Assessments
1 August 2014 in Applied Thermal Engineering
31 December 2020 in Revista de Energías Renovables
In the present study, two biofuels derived from cooking oil are evaluated. To carry out this work, an reciprocating internal combustion engine will be used, which is ready on a fully instrumented engine test bench. Firstly, the biodiesel production process is described, where soybean oil and canola oil have been used. Subsequently, the experimental section that has been used for the present investigation is described. The experimental tests are carried out: (i) modifying the degree of opening of the accelerator and (ii) using a constant load of the dynamometer. On the other hand, in the results section shows the performance of the two biofuels generated against diesel commercial. Also, in this section shows the percentage differences of: (i) engine power; (ii) mass fuel, (iii) thermal efficiency engine and, (iv) exhaust temperaturas. The tests have been carried out under different engine speed conditions of the reciprocating internal combustion engine. Where, the main average differences that have been registered in the engine test bench were: for engine power, 32 and 33%; for the mass fuel consumption of -4.5 and 5%, when using soybean biodiesel and canola biodiesel, respectively. These differences are due to the energy capacity of each biofuel and, the instantaneous evolution of combustion process inside the reciprocating internal combustion engine.
17 October 2023 in Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering
BDBhisham Kumar Dhurandher
+1
Fires and explosions in large oil storage tanks terminal cause significant loss of property and casualties and are always the concern of the world. To have proper understanding and knowledge about tank fires in terminals a detail study has been done considering various factors like safe separation distance, thermal radiation intensity and deluge water requirement. This paper offers the study of fire hazard especially the radiative heat flux absorbed by adjoining storage tanks. Large storage tanks fire has significant amount of energy release and causes strong thermal radiation to the properties and structures nearby. The thermal radiation intensity has been determined by providing safe separation distance recommended by various standards along with its permissible thermal radiation level for adjoining tanks. The calculated amount of mass flow rate of water required ranges in between 0.09 and 0.23 l/m 2 s which significantly varies from the recommendations of different code. However, by not ensuring required amount of water as a protective measure to safeguard the target tanks will put its integrity in doubt.