Ramtin Rasoulinezhad

Ramtin Rasoulinezhad

Auto-generated profile, based on publicly available information

Ramtin Rasoulinezhad

Department of Electrical and Comp. Engineering, Western University, London, Canada

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 March 2020 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
Ebrahim MohammadiEbrahim Mohammadi
Ebrahim Mohammadi
RRRamtin Rasoulinezhad
Ramtin Rasoulinezhad
GMGerry Moschopoulos
Gerry Moschopoulos
Wind shear and tower shadow effects generate severe fluctuations on the generated power of wind turbines (WTs). Consequently, in WT-integrated microgrids (MGs) with battery energy storage, these power fluctuations can generate battery microcycles that can significantly reduce the battery’s lifetime. In this paper, the impact of battery microcycles on battery lifetime is investigated and a method that uses a hybrid supercapacitor-battery energy storage system to mitigate these microcycles in a wind-diesel microgrid is proposed. The design, power allocation strategy, and control of the power converters are discussed; the supercapacitor size is determined based on the decomposition of frequency components of the WT output power, using discrete Fourier transform to appropriately mitigate the battery microcycles. The components of the MG, wind shear, and tower shadow effects are modeled in detail using MATLAB/Simulink, TurbSim, AeroDyn, and FAST software tools. Finally, the performance of the proposed method is investigated and verified in simulation, considering two case studies where either battery-only or battery-supercapacitor are used. In addition, a cost-benefit analysis of the proposed system is given. The results show that the proposed method can appropriately mitigate the battery microcycles, which can result in increasing battery lifetime and reducing the total system costs.

10 March 2021 in IEEE Access
Verified
Journal Article
Open access
RRRamtin Rasoulinezhad
Ramtin Rasoulinezhad
AAAdel Ali Abosnina
Adel Ali Abosnina
JKJavad Khodabakhsh
Javad Khodabakhsh
GMGerry Moschopoulos
Gerry Moschopoulos
The paper proposes a novel interleaved AC-DC ZCS-PWM boost converter that requires the use of just a single active auxiliary switch to assist in the turning off the main power circuit switches with ZCS. The auxiliary switch can be turned on and off with ZCS and its auxiliary circuit allows the converter to operate without an increase in the main switch peak current or voltage stress. The auxiliary switch in the converter is active for a much shorter time than in most other ZCS-PWM converter, which allows the converter to operate at higher power levels than other previously proposed interleaved ZCS-PWM converter with a single auxiliary switch. The proposed converter’s operation is explained in the paper and its key features and design considerations are discussed. Experimental results that confirm the operation of the proposed converter are presented as well.

3 June 2019 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
JKJavad Khodabakhsh
Javad Khodabakhsh
RRRamtin Rasoulinezhad
Ramtin Rasoulinezhad
GMGerry Moschopoulos
Gerry Moschopoulos
In this letter, the use of three-level (TL), zerovoltage-zero-current switching (ZVZCS) converters is investigated as a way of improving light-load efficiency in fullbridge converters with MOSFETS. The general operation of an example TL-ZVZCS full-bridge converter is briefly explained and the basic principles as to how it can how improve light-load efficiency are discussed. Experimental results that compare the efficiency of a prototype of the example TL-ZVZCS converter to that of the conventional ZVS-PWM full-bridge are presented to confirm the superior light-load efficiency of TL-ZVZCS converters.

1 March 2018
Verified
Conference Paper
Closed access
RRRamtin Rasoulinezhad
Ramtin Rasoulinezhad
AAAdel Abosnina
Adel Abosnina
GMGerry Moschopoulos
Gerry Moschopoulos
A new interleaved AC-DC boost converter is proposed in this paper. The converter uses just a single active auxiliary circuit to assist all the main converter switches operate with ZCS and operates with ZCS itself. This circuit does not increase the peak voltage or current stresses of the main switches and can be deactivated from the main pwer circuit if necessary. In this paper, the operation of the converter is fully explained, its features are discussed, and guidelines for the design of key auxiliary circuit components are given. Results obtained from an experimental prototype are presented to confirm the feasibility of the proposed converter.

1 March 2020
Verified
Conference Paper
Closed access
EMEbrahim Mohammadi
Ebrahim Mohammadi
RRRamtin Rasoulinezhad
Ramtin Rasoulinezhad
GMGerry Moschopoulos
Gerry Moschopoulos
Stochastic and periodic power fluctuations generated by phenomena such as turbulence, wind shear, and tower shadow effects in grid-connected wind energy conversion systems (WECSs) can be mitigated by using supercapacitors. An appropriate design method for the sizing of supercapacitors is highly desirable as overdesign results in extra cost and size and underdesign results in inappropriate performance. In this study, a design method for supercapacitors in WECSs that is based on the decomposition of output power frequency components using discrete Fourier transformation (DFT) and that results in an appropriate design is proposed to mitigate power fluctuations in WECSs. The proposed design method is discussed in the paper in detail and is validated with a fixed-speed grid-connected WECS using MATLAB/Simulink software.

1 October 2018
Verified
Conference Paper
Closed access
RRRamtin Rasoulinezhad
Ramtin Rasoulinezhad
AAAdel Abosnina
Adel Abosnina
GMGerry Moschopoulos
Gerry Moschopoulos
A novel AC-DC ZCS-PWM interleaved boost converter is proposed in this paper. The converter uses just one active auxiliary circuit to allow all main converter switches to operate with ZCS; moreover, the auxiliary circuit also operates with ZCS. This circuit does not increase the peak voltage or current stresses of the main switches and does not have any components in the main power path of current, which results in improved light-load efficiency. The operation of the converter is fully explained in this paper, the features of the converter are discussed, and guidelines for the design of key auxiliary circuit components are given. The feasibility of the proposed converter is confirmed with experimental results obtained from a prototype converter.