Hamza Siddique Bhatti

Hamza Siddique Bhatti

Auto-generated profile, based on publicly available information

Hamza Siddique Bhatti

Department of Mechanical Engineering, Universiti Teknologi Petronas, Seri Iskandar, Perak, Malaysia

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 February 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
HBHamza Siddique Bhatti
Hamza Siddique Bhatti
MAMuhammad Aizzuddin Abdullah
Muhammad Aizzuddin Abdullah
MHMuarij Hadeed
Muarij Hadeed
VEVorathin Epin
Vorathin Epin
HMHisham Mohamad
Hisham Mohamad
KLKok-Sing Lim
Kok-Sing Lim
A highly sensitive fibre Bragg grating (FBG) geophone with temperature insensitivity has been developed for low-frequency seismic detection. This geophone utilizes a rubber-based diaphragm combined with a differential FBG technique to enhance vibrational sensitivity and eliminate temperature effects. This innovative method achieves a high vibrational sensitivity of 169.71 pm/g across a frequency range of 1 to 36 Hz while a low temperature sensitivity of 1.21 pm/°C is obtained over the range of 10 °C to 40 °C. Frequency spectrum comparisons demonstrate that the FBG geophone performs comparably to conventional electrical geophones.

14 October 2024 in IEEE Sensors Journal
Verified
Journal Article
Closed access
HBH. S. Bhatti
H. S. Bhatti
MHM. Hadeed
M. Hadeed
EVE. Vorathin
E. Vorathin
HMHisham Mohamad
Hisham Mohamad
Measuring low-frequency signals is essential for comprehensive monitoring in oil and gas fields as well as for structural health assessments. This article introduces a cutting-edge FBG geophone with a rubber-based diaphragm structure. The structure performance was evaluated by varying diameters from 25 mm to 55 mm, thickness from 0.8 mm to 1.4 mm and mass from 0.1 gm to 3 gm. The present study aims to achieve the highest vibrational sensitivity and the lowest natural frequency. Diaphragm diameter and mass exhibited a direct correlation with sensitivity while showing an inverse relationship with the sensor’s natural frequency. In the seismic frequency range of 5 to 30 Hz, the optimal parameters for the rubber-based diaphragm were identified as a mass of 1 gm, a thickness of 1 mm and a diameter of 45 mm, yielding a sensitivity of 89.44 pm/g and a natural frequency of 39.39 Hz. At these parameters, the temperature sensitivity was also 15.67 pm/°C. The error in sensitivity and natural frequency between the finite element analysis (FEA), experimental results, and theoretical modeling was less than 10%, highlighting the high predictability of the FEA and experimental model with theoretical modeling. A geophone with this type of performance has significant potential for advancing low-frequency seismic exploration within the oil and gas industry.

1 January 2013 in International Journal of Computer and Communication Engineering
Verified
Journal Article
Closed access
TSTarandeep Singh
Tarandeep Singh
PSParvinder S. Sandhu
Parvinder S. Sandhu
HBHarbax Singh Bhatti
Harbax Singh Bhatti
The production database are transactions intensive transactions can be insert, update on the tables, failover is the replica of the production server, if there is any change we have to implement on the production and it will be automatically implemented on failover or standby database. Now a days the data on the production server is increasing and we need extra storage space on production server to keep data and this is same required on the failover. To generate reports from that data will increase load on the production server and can affect the performance of the server. There are also some threats which can cause loss of data from which we have to protect our database like Hardware failure, loss of machine. Replication is one of the methods for Backup of the running database and its immediate failover during failure. This paper represents some parts for the replication techniques, failover, and transaction states

21 September 2026 in Optics Communications
Verified
Journal Article
Closed access
HBH.S. Bhatti
H.S. Bhatti
MHM. Hadeed
M. Hadeed
MAM. Aizzuddin
M. Aizzuddin
EVE. Vorathin
E. Vorathin
MAM.S. Afzal
M.S. Afzal
HMH. Mohamad
H. Mohamad