1 November 2013 in Journal of Instrumentation
1 January 2016 in Journal of Instrumentation
21 June 2000 in Physics of Plasmas
The density profiles were measured in the Hefei tokamak-7 (HT-7) [World Survey of Activities in Controlled Fusion Research, Nuclear Fusion Special Supplement (International Atomic Energy Agency, Vienna, 1997), p. 61] ohmic discharges by means of a new multichannel far-infrared (FIR) laser interferometer. The progress on the extension of the HT-7 ohmic discharge operation region was introduced. The experiment results at the density limit, the multifaceted asymmetric radiation from the edge (MARFE) phenomena, the rf (radio frequency) boronization experiments, and the fueling efficiency studies were reported. The plasma physics in the molecular beam injection (MBI), the pellet injection (PI), and the gas puffing (GP) fueling experiments was studied and discussed.
1 November 1999 in Plasma Physics and Controlled Fusion
In the HT-7 superconducting tokamak, the onset of a multifaceted asymmetric radiation from the edge (MARFE) usually occurs in the early ohmic discharges of each experimental campaign before wall conditioning. The occurrence and location of a MARFE is identified by different diagnostic systems. An improved confinement mode plasma which was induced by the MARFE is observed, and the global particle confinement time increases 1.9 times. The relaxation time between the MARFE event trigger and the L-H transition is about 1.4 ms, the following L-H transition time is 1.9 ms, and the improved confinement mode phase is maintained for about 40 ms. The MARFE cools the plasma edge, and the electron density profile is observed to become more narrow and peaked. The occurrence of a MARFE is strongly correlated with Zeff but not with the density, and it always occurs at Zeff = 3-8 ohmic discharges. In the case of a good wall condition (Zeff = 1-2), the onset of MARFEs has not been observed before reaching the Greenwald density limit.
1 December 2017 in Journal of Instrumentation
Plasma equilibrium reconstruction plays an important role in the tokamak plasma research. With a high temporal and spatial resolution, the POlarimeter-INTerferometer (POINT) system on EAST has provided effective measurements for 102s H-mode operation. Based on internal Faraday rotation measurements provided by the POINT system, the equilibrium reconstruction with a more accurate core current profile constraint has been demonstrated successfully on EAST. Combining other experimental diagnostics and external magnetic fields measurement, the kinetic equilibrium has also been reconstructed on EAST. Take the pressure and edge current information from kinetic EFIT into the equilibrium reconstruction with Faraday rotation constraint, the new equilibrium reconstruction not only provides a more accurate internal current profile but also contains edge current and pressure information. One time slice result using new kinetic equilibrium reconstruction with POINT data constraints is demonstrated in this paper and the result shows there is a reversed shear of q profile and the pressure profile is also contained. The new improved equilibrium reconstruction is greatly helpful to the future theoretical analysis.
1 November 2015 in Journal of Instrumentation
The HCN laser on EAST is a continuous wave glow discharge laser with 3.4 m cavity length and 120 mW power output at 337 μ m wavelength. Without a temperature-controlled system, the cavity length of the laser is very sensitive to the environmental temperature. An external power feedback control system is applied on the HCN laser to stabilize the laser output power. The feedback system is composed of a stepping motor, a PLC, a supervisory computer, and the corresponding control program. One step distance of the stepping motor is 1 μ m and the time response is 0.5 s. Based on the power feedback control system, a stable discharge for the HCN laser is obtained more than eight hours, which satisfies the EAST experiment.