Jinhai Hu

Jinhai Hu

Auto-generated profile, based on publicly available information

Jinhai Hu

Daqing Oilfield Company Ltd., Daqing, China

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 October 2016 in Sensors
Verified
Journal Article
Open access
PDF file
YWYanjun Wang
Yanjun Wang
HLHaoyu Li
Haoyu Li
LXLiu Xingbin
Liu Xingbin
YZYuhui Zhang
Yuhui Zhang
RXRonghua Xie
Ronghua Xie
GDGang Deng
Gang Deng
First, the measuring principle, the weight function, and the magnetic field of the novel downhole inserted electromagnetic flowmeter (EMF) are described. Second, the basic design of the EMF is described. Third, the dynamic experiments of two EMFs in oil-water two-phase flow are carried out. The experimental errors are analyzed in detail. The experimental results show that the maximum absolute value of the full-scale errors is better than 5%, the total flowrate is 5–60 m3/d, and the water-cut is higher than 60%. The maximum absolute value of the full-scale errors is better than 7%, the total flowrate is 2–60 m3/d, and the water-cut is higher than 70%. Finally, onsite experiments in high-water-cut oil-producing wells are conducted, and the possible reasons for the errors in the onsite experiments are analyzed. It is found that the EMF can provide an effective technology for measuring downhole oil-water two-phase flow.

19 November 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
XZXiaokai Zhang
Xiaokai Zhang
JSJiangtao Sun
Jiangtao Sun
JHJinhai Hu
Jinhai Hu
XLXiaolei Liu
Xiaolei Liu
LXLiu Xingbin
Liu Xingbin
LXLijun Xu
Lijun Xu
This article proposed a modified adaptive (MA) cross correlation method to measure the flow rate of high-water-cut oil-water two-phase flow. It asynchronously commences the acquisitions of the upstream and downstream signals for cross correlation according to the flow rate, enhancing the degree of correlation between them, thus a higher measurement accuracy of transition time can be obtained. By limiting the searching scope of the correlogram’s peak value in a transition time-related observation window, the calculation process is kept steady and divergence due to the outliers is effectively avoided. A planar flowmeter is adopted for high-water-cut flow rate measurement, and the advantages in axial resolution and sensitivity are analyzed. Experiments are conducted in 90% water cut oil-water flow in a practical vertical well. Results show that compared to the conventional (C) one, the MA method is capable of fast and reliable capture of the transition time from the upstream to the downstream sensors in a much wider flow rate range, with much lower deviation and a higher degree of correlation. Finally, the flow rates and their uncertainties are calculated from the measured transition time to validate the measurement stability.

15 December 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
XZXiaokai Zhang
Xiaokai Zhang
JSJiangtao Sun
Jiangtao Sun
JHJinhai Hu
Jinhai Hu
PSPeng Suo
Peng Suo
LXLiu Xingbin
Liu Xingbin
LXLijun Xu
Lijun Xu
Due to long-term exploitation of oil wells, high water-cut oil-water two-phase flow has become one of the most common flow types in offshore oil fields. In this work, two cross-correlation flowmeters for this type of flow, i.e. the newly proposed transverse excitation mode flowmeter and the conventional axial excitation mode flowmeter are theoretically analyzed, numerically solved and experimentally compared. By building theoretical models, the resolutions and sensitivities of the sensors are systematically compared to demonstrate their abilities of detecting oil bubbles in water. From the numerical solutions by the FEM models, the resolutions of the sensors are analyzed in spatial frequency domain, and more accurate analysis of sensitivities can be made. Results show that the resolution of the transverse excitation mode flowmeter is approximately 3 times higher, and the sensitivity is at most 3.47 times higher than the axial excitation mode one. Experiments with 10 m 3 /d, 90%-water-cut oil-water two-phase flow are carried out to demonstrate the dynamic performances of the two flowmeters. It can be concluded that the transverse excitation mode flowmeter has higher accuracy and reliability in flow rate measurement.