9 June 2023 in IEEE Transactions on Instrumentation and Measurement
This article presents an adaptive group-based sparse representation scheme for image reconstruction in electrical capacitance tomography. Compared to conventional sparsity-based methods, the proposed method can accurately recover the shape and location of abnormities by exploiting local self-similarity and the sparsity of the image in the form of group, consisting of a central block and neighboring local blocks. Each group can be represented by sparse coefficients and representation matrices obtained via adaptive self-learning from the current reconstructed image, leading to more sparsity and less computation. This scheme can be efficiently solved by the split Bregman iteration method, which can achieve accurate reconstruction within a few iterations. It has advantages in efficiently exploring the global sparsity and neighboring self-similarity in the reconstructed image simultaneously for enhanced image quality. Numerical simulations and phantom experiments were carried out to validate the proposed method. Results show that the proposed method can reconstruct more accurate images of abnormities of complex shapes than typical sparsity-based methods by consuming less computational resources. This is of great potential in fulfilling the high requirements on both the temporal and spatial resolutions in the imaging of dynamic processes, such as multiphase flows.
16 October 2024 in IEEE Transactions on Instrumentation and Measurement
This article presents a novel approach to measuring gas-liquid two-phase flow using a throat-extended Venturi meter (TEVM) based on differential pressure (DP) ratios and fluctuations. The over-reading (OR) and mass quality are the dominant parameters for accurate mass flowrate measurement by a TEVM. First, a liquid OR model is established based on multiple DP ratios, gas-to-liquid density ratio, and liquid densitometric Froude number. This model is solved by integrating a deep neural network (DNN) with an iterative optimization technique. Subsequently, a mass quality model is developed based on multi-DP fluctuations and other related parameters, which can also be solved using a DNN. Finally, the liquid and gas mass flowrates are obtained sequentially from the preceding results. The proposed method addresses the issue of significant errors in the direct solution of the conventional dual-parameter measurements. It utilizes both the static and dynamic features of multi-DP to achieve the simultaneous measurement of gas and liquid mass flowrate using a single TEVM. The experiment was conducted within the a gas flowrate range of 1.3×10 -4 ~5.1×10 -3 kg/s, and a liquid flowrate range of 1.12~3.95 kg/s. The results demonstrate that the relative error for liquid and gas mass flowrate is within ±3% and ±10%, respectively. This indicates that the proposed method is a cost-effective and viable solution for gas-liquid two-phase flow metering using a TEVM, and it can be further adapted to other experimental conditions.
19 November 2021 in IEEE Transactions on Instrumentation and Measurement
This article proposed a modified adaptive (MA) cross correlation method to measure the flow rate of high-water-cut oil-water two-phase flow. It asynchronously commences the acquisitions of the upstream and downstream signals for cross correlation according to the flow rate, enhancing the degree of correlation between them, thus a higher measurement accuracy of transition time can be obtained. By limiting the searching scope of the correlogram’s peak value in a transition time-related observation window, the calculation process is kept steady and divergence due to the outliers is effectively avoided. A planar flowmeter is adopted for high-water-cut flow rate measurement, and the advantages in axial resolution and sensitivity are analyzed. Experiments are conducted in 90% water cut oil-water flow in a practical vertical well. Results show that compared to the conventional (C) one, the MA method is capable of fast and reliable capture of the transition time from the upstream to the downstream sensors in a much wider flow rate range, with much lower deviation and a higher degree of correlation. Finally, the flow rates and their uncertainties are calculated from the measured transition time to validate the measurement stability.
15 December 2022 in IEEE Sensors Journal
Due to long-term exploitation of oil wells, high water-cut oil-water two-phase flow has become one of the most common flow types in offshore oil fields. In this work, two cross-correlation flowmeters for this type of flow, i.e. the newly proposed transverse excitation mode flowmeter and the conventional axial excitation mode flowmeter are theoretically analyzed, numerically solved and experimentally compared. By building theoretical models, the resolutions and sensitivities of the sensors are systematically compared to demonstrate their abilities of detecting oil bubbles in water. From the numerical solutions by the FEM models, the resolutions of the sensors are analyzed in spatial frequency domain, and more accurate analysis of sensitivities can be made. Results show that the resolution of the transverse excitation mode flowmeter is approximately 3 times higher, and the sensitivity is at most 3.47 times higher than the axial excitation mode one. Experiments with 10 m 3 /d, 90%-water-cut oil-water two-phase flow are carried out to demonstrate the dynamic performances of the two flowmeters. It can be concluded that the transverse excitation mode flowmeter has higher accuracy and reliability in flow rate measurement.
3 June 2025 in IEEE Sensors Journal
This article presents a novel method for measuring the mass flow rate of gas-liquid two-phase flow based on the multi-sensor data fusion and soft computing model. A multi-sensor system comprising a throat-extended Venturi tube and a dual-modality electrical sensor has been developed for gas-liquid two-phase flow measurement. Soft computing models are employed to address the intricate non-linear mapping between the measurement data and flow parameters. Initially, flow regimes are identified based on the time-domain features of the multi-sensor data using a support vector machine. Subsequently, mass quality is derived from the multi-differential pressure fluctuations and the eigenvalue sequence of the normalized electrical matrices, employing a hybrid neural network comprising a convolution neural network and a deep neural network. Ultimately, gas/liquid over-reading is predicted via Extreme Gradient Boosting using multi-differential pressure ratios. The gas and liquid mass flow rates are subsequently derived from the preceding results. The proposed method addresses the issue that the parameters measurement of gas-liquid two-phase flow is significantly influenced by the flow regimes, and achieves accurate flow rate measurement under the diverse flow regimes. Experimental validation confirms the method’s effectiveness and superior performance compared to conventional approaches.