Large-signal impedance of grid-connected converters can be used to predict resonance-generated distortions in converter-grid systems. Note that the large-signal impedance of a network represents its impedance response for different magnitudes of perturbation injected at its terminals. This paper presents large-signal impedance-based modeling and mitigation of resonance of grid-connected voltage source converters (VSCs). Challenges of large-signal modeling because of the inapplicability of the small-signal approximation are addressed by leveraging the dominating influence of hard nonlinearities (such as pulse-width modulation saturation and limiters) over soft nonlinearities (such as Park's transformations and PLL) in shaping the large-signal behavior of the converter. The paper develops large-signal gains of hard nonlinearities using different types of describing functions. The paper shows that the large-signal impedance of a VSC can be shaped to reduce resonance-generated distortions by inserting limiters in the control system of the VSC. Developed large-signal impedance models are validated using numerical simulations of a VSC with dq current control and PLL. Large-signal impedance measurements of a commercial 1 MW VSC-based inverter and a medium-voltage doubly-fed induction generator with approximate 4 MW rating are presented to experimentally demonstrate the influence of the injected perturbation magnitude on the impedance response.
31 July 2023 in IEEE Transactions on Sustainable Energy
We have shown in previous work that the risk of subsynchronous resonance between wind power plants with Type III wind turbines and series-compensated transmission lines is low when the wind turbines are operated in grid-forming (GFM) mode instead of the standard grid-following mode. This article explains the fundamental mechanism behind the improved damping characteristics by modeling the positive- and negative-sequence impedances of Type III wind turbines in GFM control mode. It is discovered that the GFM control naturally acts against the negative resistance behavior of Type III wind turbines at subsynchronous frequencies that results from an interaction between the rotor-side converter current controller and negative slip. The developed impedance models in the sequence domain and the improved damping behavior are verified using PSCAD simulations of a 2.5-MW Type III GFM wind turbine. The modeling predictions are also supported by experimentally measuring the impedance response of a 2.5-MW Type III wind turbine in GFM mode.
Grid integration testing of inverter-coupled renewable energy technologies is an essential step in the qualification of renewable energy and energy storage systems to ensure the stability of the power system. New types of devices must be thoroughly tested and validated for compliance with relevant grid codes and interconnection requirements. For this purpose, highly specialized custom-made testing equipment is needed to emulate various types of realistic grid conditions that are required by certification bodies or for research purposes. For testing multi-megawatt converters, a high power grid simulator capable of creating controlled grid conditions and meeting both power quality and dynamic characteristics is needed. This paper describes the new grid simulator concept based on ABB's medium voltage ACS6000 drive technology that utilizes advanced modulation and control techniques to create an unique testing platform for various multi-megawatt power converter systems. Its performance is demonstrated utilizing the test results obtained during commissioning activities at the National Renewable Energy Laboratory in Colorado, USA.
In recent years, there has been a growing interest in full-scale wind turbine nacelle testing to complement individual component testing. As a result, several wind turbine nacelle test benches have been built to perform such testing with the intent of loading the integrated components as they are in the field. However, when mounted on a test bench the nacelle is not on the top of a tower and does not have blades attached to it — this is a form of abstraction. This paper aims to quantify the influence of such an abstraction on the dynamic response of the nacelle through a series of simulation case studies. The responses of several nacelle components are studied including the main bearing, main shaft, gearbox supports, generator, and yaw bearing interface. Results are presented to highlight the differences in the dynamic response of the nacelle caused by the abstraction. Additionally, the authors provide recommendations for mitigating the effects of the abstraction.