José Eduardo Gubaua

José Eduardo Gubaua

Auto-generated profile, based on publicly available information

José Eduardo Gubaua

Federal University of Parana

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2017 in Clinical Biomechanics
Verified
Journal Article
Closed access
ILIevgen Levadnyi
Ievgen Levadnyi
Jan AwrejcewiczJan Awrejcewicz
Jan Awrejcewicz
JGJosé Eduardo Gubaua
José Eduardo Gubaua
JPJucélio Tomás Pereira
Jucélio Tomás Pereira

4 July 2020 in Biomechanics and Modeling in Mechanobiology
Verified
Journal Article
Closed access
PDF file
MAMehran Ashrafi
Mehran Ashrafi
JGJosé Eduardo Gubaua
José Eduardo Gubaua
JPJucélio Tomás Pereira
Jucélio Tomás Pereira
FGFarzan Ghalichi
Farzan Ghalichi
Manuel DoblaréManuel Doblaré
Manuel Doblaré

12 July 2019 in Biomechanics and Modeling in Mechanobiology
Verified
Journal Article
Closed access
PDF file
MSMehdi Saeidi
Mehdi Saeidi
JGJosé Eduardo Gubaua
José Eduardo Gubaua
PKPiaras Kelly
Piaras Kelly
MKMousa Kazemi
Mousa Kazemi
TBThor Besier
Thor Besier
MRMaziar Ramezani
Maziar Ramezani

18 August 2020 in Medical Engineering & Physics
Verified
Journal Article
Closed access
JGJosé Eduardo Gubaua
José Eduardo Gubaua
GDGabriela Wessling Oening Dicati
Gabriela Wessling Oening Dicati
Emilio Graciliano Ferreira MercuriEmilio Graciliano Ferreira Mercuri
Emilio Graciliano Ferreira Mercuri
JPJucélio Tomás Pereira
Jucélio Tomás Pereira
The present study focuses on a model for three-dimensional bone remodeling of the human femur that considers cellular dynamics to determine the volume fraction of new bone. The model considers the interaction among responsive osteoblasts, active osteoblasts, and osteoclasts, as well as signaling molecules and parathyroid hormone (PTH). The stimulus of the model has a systemic origin due to the PTH effect, and a local origin due to the action of cytokines, growth factors, and mechanical stimuli near the site of the bone cells. The present work considers that the mechanical stimulus that activates cellular activity is obtained from stresses acting on the bone tissue and the number of daily loading cycles. In addition to simulating the bone modeling process in an intact femur, the numerical model is used to simulate bone adaptation in relation to the stress shielding phenomenon after the implantation of a femoral prosthesis. The results showed that the simulations provide a distribution of bone density that is similar to a radiograph and, in addition, allows the visualization of osteoblast and osteoclast dynamics in bone adaptation response after prosthesis implantation.

12 December 2021 in Medical Engineering & Physics
Verified
Journal Article
Closed access
JGJosé Eduardo Gubaua
José Eduardo Gubaua
GDGabriela Wessling Oening Dicati
Gabriela Wessling Oening Dicati
JSJéderson da Silva
Jéderson da Silva
JVJoão Luiz Do Vale
João Luiz Do Vale
JPJucélio Tomás Pereira
Jucélio Tomás Pereira
The checkerboard phenomenon is a numerical problem that can occur in bone remodeling simulations. This phenomenon degrades the quality of the results and emphasizes a strong mesh dependency. The node-based approach is a well-used method for solving this problem. However, this method does not provide a stable solution, and long-time simulations do not reach steady-state. This paper aims to discuss techniques for mitigating the checkerboard formation and obtaining bone characterization. For this, we apply the simple nodal average technique on stress, density, or both simultaneously. Then, we compare the element-based and node-based approaches with and without smoothing. Also, we introduced a quantification parameter called standard density variation. This parameter measures the intensity of the checkerboard formation and analyzes the evolution of the bone tissue behavior. The application of the smoothing techniques mitigates the checkerboard formation. Also, the application allows obtaining a stable behavior for long-time simulations. The standard density variation allowed visualizing this stable behavior. In particular, the stress field smoothing technique provides the best results. Besides the stabilization and checkerboard control, the technique allows obtaining a physiological density distribution.

8 October 2020 in Medical Engineering & Physics
Verified
Journal Article
Closed access
GDGabriela Wessling Oening Dicati
Gabriela Wessling Oening Dicati
JGJosé Eduardo Gubaua
José Eduardo Gubaua
JPJucélio Tomás Pereira
Jucélio Tomás Pereira
Simulation of the bone remodeling process is extremely important because it makes possible the structure forecast of one or several bones when anomalous situations, such as prosthesis installation, occur. Thus, it is necessary that the mathematical model to simulate the bone remodeling process be reliable; that is, the numerical solution must be stable regardless of initial density field for a phenomenological approach to model the process. For several models found in the literature, this characteristic of stability is not observed, largely due to the discontinuities present in the property values of the models (e.g., Young's modulus and Poisson's ratio). In addition, checkerboard formation and the lazy zone prevent the uniqueness of the solution. To correct these difficulties, this study proposes a set of modifications to guarantee the uniqueness and stability of the solutions, when a phenomenological approach is used. The proposed modifications are: (a) change the rate of remodeling curve in the lazy zone region and (b) create transition functions to guarantee the continuity of the expressions used to describe Young's modulus and Poisson's ratio. Moreover, the stress smoothing process controls the checkerboard formation. Numerical analysis is used to simulate the solution behavior from each proposed modification. The results show that, when all proposed modifications are applied to the three-dimensional models simulated here, it is possible to observe the tendency toward a unique solution.