Lucia Gallego Manzano

Lucia Gallego Manzano

Auto-generated profile, based on publicly available information

Lucia Gallego Manzano

Institute of Radiation Physics, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 June 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Open access
LML. Gallego Manzano
L. Gallego Manzano
HBHamza Boukabache
Hamza Boukabache
SDSalvatore Danzeca
Salvatore Danzeca
NHNatalie Heracleous
Natalie Heracleous
FMFabrizio Murtas
Fabrizio Murtas
MSMarco Silari
Marco Silari
A reliable and highly scalable Internet of Things (IoT) end-to-end data infrastructure has been developed for environmental radiation monitoring at CERN based on a Low-Power Wide-Area Network (LPWAN). The proposed system,called W-MON (Waste radiation MONitoring), consists of an interconnected network of thousands of highly sensitive and ultra-low power gamma radiation sensors acting as LoRa transceivers. The aim of the system is to improve and automatize the radiological controls of conventional waste containers. The end-devices measure the radiation levels in the waste containers on a continuous basis and send the data periodically to the LoRaWAN network server. The network has been deployed in an outdoor environment covering hundreds of hectares. A set of web-based user applications for real-time monitoring, data visualization and status control of the devices have been designed based on open source tools. The data pipeline infrastructure has been designed to allow an easy integration into REMUS, the overall CERN Radiation and Environment Monitoring Unified Supervision service.

1 July 2015 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
LML. Gallego Manzano
L. Gallego Manzano
SBS. Bassetto
S. Bassetto
NBN. Beaupere
N. Beaupere
PBP. Briend
P. Briend
TCT. Carlier
T. Carlier
DTD. Thers
D. Thers

1 September 2021 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
FFF. Ferrulli
F. Ferrulli
NDN. Dinar
N. Dinar
LML. Gallego Manzano
L. Gallego Manzano
MLM. Labalme
M. Labalme
MSM. Silari
M. Silari

11 March 2023 in Medical Physics
Verified
Journal Article
Open access
LMLucía Gallego Manzano
Lucía Gallego Manzano
PMPascal Monnin
Pascal Monnin
YSYann Sayous
Yann Sayous
FBFabio Becce
Fabio Becce
JDJérôme Damet
Jérôme Damet
AVAnaïs Viry
Anaïs Viry
Background: Acceptance testing and quality assurance (QA) of computed tomography (CT) scans are of great importance to ensure the appropriate performance of the systems. However, current standards and guidelines do not include a dedicated QA program for spectral photon‐counting CT (SPCCT), nor adapted tolerance levels.Purpose: To evaluate the technical performance, in terms of image quality and radiation dose, of the first point‐of‐care SPCCT for the upper extremities (MARS Extremity 5X120, MARS Bioimaging Ltd., Christchurch, New Zealand) and to establish a comprehensive QA program.Methods: The specific dimensions of the scanner with a 125 mm diameter gantry and a small voxel size of 0.1 × 0.1 × 0.1 mm3 require the use of suitable phantoms and evaluation techniques. Indicators such as CT number accuracy, image noise, uniformity, and slice thickness were assessed to characterize the image quality. The in‐plane and longitudinal spatial resolutions were evaluated by means of the modulation transfer function (MTF). Noise power spectra (NPS) were calculated to further evaluate the image noise. Material identification capabilities were assessed using clinically relevant high‐Z materials (iodine, gold, gadolinium, and calcium). A 100‐mm diameter CTDI‐like phantom was used to measure the dose indices. A complete radiation survey was carried out to measure the radiation exposure at different points around the scanner.Results: The proposed QA program is based on international and local recommendations as well as practical experience. It includes standardised CT tests and SPCCT‐specific methods. Additional methodologies to further assess the system performance are also presented. Tolerance levels are discussed and revised when appropriate. Both in‐plane and longitudinal high spatial resolutions were evidenced by the MTF measurements with 1.8 lp· mm−1 and 5.0 lp· mm−1 at 10%, respectively. The calculated effective slice thickness ranged between 0.15 and 0.16 mm for the five energy bins and for a reconstructed voxel size of 0.1 × 0.1 × 0.1 mm3. Reference values of the linear attenuation coefficient of water have been calculated and used to assess the CT number uniformity of water. Evaluation of the CT number accuracy and stability of various clinically relevant materials showed excellent spectral correlation and linearity between HU values and concentrations (r2 > 0.99). The NPS showed less noise correlation between slices than within transverse slice, as well as a systematic increase at low spatial frequencies. The volume CT dose index (CTDI) for a custom‐made 100 mm diameter phantom was 9.32 mGy. Radiation measurements around the scanner showed that it is completely shielded except for the access port, and that no additional protective measures are necessary for the patient.Conclusions: A routine QA framework for SPCCT systems has been proposed. Image quality and radiation dose were assessed using newly designed phantoms, relevant metrics, and automated algorithms. Baseline values were established and tolerance levels discussed for the MARS SPCCT scanner based on collected data and international recommendations.

13 July 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
AOAndreia Maia Oliveira
Andreia Maia Oliveira
HAHylke B. Akkerman
Hylke B. Akkerman
Saverio BracciniSaverio Braccini
Saverio Braccini
ABAlbert J. J. M. van Breemen
Albert J. J. M. van Breemen
LMLucia Gallego Manzano
Lucia Gallego Manzano
MSMarco Silari
Marco Silari
Quality Assurance (QA) in hadron therapy is crucial to ensure safe and accurate dose delivery to patients. This can be achieved with fast, reliable and high-resolution detectors. In this paper, we present a novel solution that combines a triple Gas Electron Multiplier (GEM) and a highly pixelated readout based on a matrix of organic photodiodes fabricated on top of an oxide-based thin-film transistor backplane. The first LaGEMPix prototype with an active area of 60 × 80 mm2 was developed and characterized using low energy X-rays. The detector comprises a drift gap of 3.5 mm, a triple-GEM stack for electron amplification, and a readout featuring 480 × 640 pixels at a 126 µm pitch. Here, we describe the measurements and results in terms of spatial resolution for various experimental configurations. A comparison with GAFCHROMIC® films and the GEMPix detector used in the charge readout mode was performed to better understand the contribution to the spatial resolution from both the electron diffusion and the isotropic emission of photons. The measurements were compared to Monte Carlo simulations, using the FLUKA code. The simulation predictions are in good agreement with the GEMPix results. Future plans with respect to applications in hadron therapy are discussed.

30 June 2026 in Physica Medica
Verified
Journal Article
Open access
ESEleni Theano Samara
Eleni Theano Samara
JEJonas Ekeberg
Jonas Ekeberg
GPGustavo S.P. Pamplona
Gustavo S.P. Pamplona
ASAnja Stüssi
Anja Stüssi
RTReto Treier
Reto Treier
ASArdan M. Saguner
Ardan M. Saguner
Diagnostic reference levels (DRLs) have been proven to be a useful tool for optimizing patient radiation exposure. National DRLs (NDRLs) are defined based on data from a representative sample of the healthcare facilities in a particular country. This project presents the survey to update the NDRLs for cardiac interventional procedures in Switzerland. Healthcare facilities performing cardiac procedures in Switzerland were asked to provide radiation dose data for adult cardiac interventional procedures performed over the course of one year. The dataset included the procedure name and the corresponding air kerma area product, air kerma at the reference point, fluoroscopy time and number of cine acquisitions. Thirty-five healthcare facilities (95% of the total) provided data. The procedures were grouped into 11 electrophysiology procedures, 4 cardiac catheterization procedures, and 3 structural heart procedures. For each healthcare facility and radiation quantity, the median values were calculated. Updated NDRLs were determined as the 75th percentile of the distribution of these median values. For example, the updated NDRL for air kerma area product was set at 24 Gy∙cm2 for coronary angiography and at 2 Gy∙cm2 for pacemaker implantation, reflecting a substantial reduction from the prior NDRL values of 50 and 30 Gy∙cm2, respectively. These new NDRL values are substantially lower than the previous ones, highlighting the importance of conducting regular updates to accommodate continuous patient dose optimization of and technological advancements.