Nadia Shaira Shafii

Nadia Shaira Shafii

Auto-generated profile, based on publicly available information

Nadia Shaira Shafii

Faculty of Electrical Engineering, Universiti Teknologi Malaysia, 81310 Skudai, Malaysia

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 May 2022 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
RYRyuhei Yamaguchi
Ryuhei Yamaguchi
GTGaku Tanaka
Gaku Tanaka
NSNadia Shaira Shafii
Nadia Shaira Shafii
KOKahar Osman
Kahar Osman
YSYasutomo Shimizu
Yasutomo Shimizu
MOMakoto Ohta
Makoto Ohta
The mechanisms underlying the growth and rupture of aneurysms are poorly understood. Although the wall shear stress (WSS) in elastic aneurysm models is examined using fluid-structure interaction (FSI) simulations, it has not been sufficiently validated using experimental modalities, such as particle image velocimetry (PIV) or phase contrast magnetic resonance imaging (PC-MRI). In this study, we investigated pulsatile flow in an elastic, image-based, patient-specific cerebral aneurysm model using PIV. The phantom model was carefully fabricated using a specialized technique by silicone elastomer. We explored the hemodynamics of the WSS and the kinetic energy cascade (KEC) in the elastic model compared with a rigid model, at the apex of the bifurcation of the middle cerebral artery (MCA) in vitro. The effects of elasticity on the WSS, WSS gradient (WSSG), and tensile strength of the aneurysm wall were also investigated, in addition to the effect of wall elasticity on the KEC compared to a rigid wall. Although the WSSG around the stagnation point had a large positive value, there was no difference between the two models. In particular, wall elasticity suppressed the WSS magnitude around the stagnation point and attenuated the KEC (i.e., the flow fluctuation). Future studies examining KEC frequency and WSS characteristics in a phantom model should consider assessing elasticity.

1 August 2025 in Medical Engineering & Physics
Verified
Journal Article
Closed access
RYRyuhei Yamaguchi
Ryuhei Yamaguchi
MAMuhamed Albadawi
Muhamed Albadawi
NSNadia Shaira Shafii
Nadia Shaira Shafii
ASAtsushi Saito
Atsushi Saito
TNToshiyuki Nakata
Toshiyuki Nakata
MOMakoto Ohta
Makoto Ohta
The hemodynamics of elastic cerebral aneurysms are complicated by phenomena that affect the initiation and the progress of each aneurysm. The blood vessel deforms with pulsatile flow. In a phantom, however, it remains unclear whether the wall compliance can be neglected. In our previous study, the flow structure at another plane oriented perpendicular to the median plane was not clarified. In the approach presented here, an identical phantom is used for both the rigid and elastic wall models by adjusting the surrounding fluid when immersed in a bath. For this purpose, the full-scale phantom of an aneurysm was fabricated using a silicone elastomer. The hemodynamic factors at the orthogonal planes in the non-deformable and deformable models of the bifurcation in the middle cerebral artery were examined. Using two-dimensional particle image velocimetry, the flow velocity, the wall shear stress (WSS), the WSS gradient (WSSG), and the turbulent kinetic energy (TKE) were measured during pulsatile flow. Overall, the WSSG at the median plane is smaller than that at corresponding perpendicular plane. Additionally, the TKE in the deformable model is smaller than that in the non-deformable model. Our results have clarified the complex effects of aneurysm wall compliance on these hemodynamic factors.