Irene K. Veldhuijzen

Irene K. Veldhuijzen

Auto-generated profile, based on publicly available information

Irene K. Veldhuijzen

Centre for infectious disease control, National institute for public health and the environment (RIVM), Bilthoven, the Netherlands

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 February 2022 in Eurosurveillance
Verified
Journal Article
Open access
JBJantien A Backer
Jantien A Backer
DEDirk Eggink
Dirk Eggink
SAStijn P Andeweg
Stijn P Andeweg
IVIrene K Veldhuijzen
Irene K Veldhuijzen
NMNoortje van Maarseveen
Noortje van Maarseveen
JWJacco Wallinga
Jacco Wallinga
The SARS-CoV-2 Omicron variant has a growth advantage over the Delta variant because of higher transmissibility, immune evasion or shorter serial interval. Using S gene target failure (SGTF) as indication for Omicron BA.1, we identified 908 SGTF and 1,621 non-SGTF serial intervals in the same period. Within households, the mean serial interval for SGTF cases was 0.2–0.6 days shorter than for non-SGTF cases. This suggests that the growth advantage of Omicron is partly due to a shorter serial interval.

27 July 2021 in BMJ
Verified
Journal Article
Open access
PDF file
ESEwoud Schuit
Ewoud Schuit
IVIrene K Veldhuijzen
Irene K Veldhuijzen
RVRoderick P Venekamp
Roderick P Venekamp
WBWouter van Den Bijllaardt
Wouter van Den Bijllaardt
SPSuzan Pas
Suzan Pas
KMKarel G M Moons
Karel G M Moons
Objective To assess the diagnostic test accuracy of two rapid antigen tests in asymptomatic and presymptomatic close contacts of people with SARS-CoV-2 infection on day 5 after exposure. Design Prospective cross sectional study. Setting Four public health service covid-19 test sites in the Netherlands. Participants 4274 consecutively included close contacts (identified through test-and-trace programme or contact tracing app) aged 16 years or older and asymptomatic for covid-19 when requesting a test. Main outcome measures Sensitivity, specificity, and positive and negative predictive values of Veritor System (Beckton Dickinson) and Biosensor (Roche Diagnostics) rapid antigen tests, with reverse-transcriptase polymerase chain reaction (RT-PCR) testing as reference standard. The viral load cut-off above which 95% of people with a positive RT-PCR test result were virus culture positive was used as a proxy of infectiousness. Results Of 2678 participants tested with Veritor, 233 (8.7%) had a RT-PCR confirmed SARS-CoV-2 infection of whom 149 were also detected by the rapid antigen test (sensitivity 63.9%, 95% confidence interval 57.4% to 70.1%). Of 1596 participants tested with Biosensor, 132 (8.3%) had a RT-PCR confirmed SARS-CoV-2 infection of whom 83 were detected by the rapid antigen test (sensitivity 62.9%, 54.0% to 71.1%). In those who were still asymptomatic at the time of sampling, sensitivity was 58.7% (51.1% to 66.0%) for Veritor (n=2317) and 59.4% (49.2% to 69.1%) for Biosensor (n=1414), and in those who developed symptoms were 84.2% (68.7% to 94.0%; n=219) for Veritor and 73.3% (54.1% to 87.7%; n=158) for Biosensor. When a viral load cut-off was applied for infectiouness (≥5.2 log10 SARS-CoV-2 E gene copies/mL), the overall sensitivity was 90.1% (84.2% to 94.4%) for Veritor and 86.8% (78.1% to 93.0%) for Biosensor, and 88.1% (80.5% to 93.5%) for Veritor and 85.1% (74.3% to 92.6%) for Biosensor, among those who remained asymptomatic throughout. Specificities were >99%, and positive and negative predictive values were >90% and >95%, for both rapid antigen tests in all analyses. Conclusions The sensitivities of both rapid antigen tests in asymptomatic and presymptomatic close contacts tested on day 5 onwards after close contact with an index case were more than 60%, increasing to more than 85% after a viral load cut-off was applied as a proxy for infectiousness.

14 September 2022 in BMJ
Verified
Journal Article
Open access
PDF file
ESEwoud Schuit
Ewoud Schuit
RVRoderick P Venekamp
Roderick P Venekamp
LHLotty Hooft
Lotty Hooft
IVIrene K Veldhuijzen
Irene K Veldhuijzen
WBWouter van Den Bijllaardt
Wouter van Den Bijllaardt
KMKarel G M Moons
Karel G M Moons
Objective: To assess the performance of rapid antigen tests with unsupervised nasal and combined oropharyngeal and nasal self-sampling during the omicron period.Design: Prospective cross sectional diagnostic test accuracy study.Setting: Three public health service covid-19 test sites in the Netherlands, 21 December 2021 to 10 February 2022.Participants: 6497 people with covid-19 symptoms aged ≥16 years presenting for testing.Interventions: Participants had a swab sample taken for reverse transcription polymerase chain reaction (RT-PCR, reference test) and received one rapid antigen test to perform unsupervised using either nasal self-sampling (during the emergence of omicron, and when omicron accounted for >90% of infections, phase 1) or with combined oropharyngeal and nasal self-sampling in a subsequent (phase 2; when omicron accounted for >99% of infections). The evaluated tests were Flowflex (Acon Laboratories; phase 1 only), MPBio (MP Biomedicals), and Clinitest (Siemens-Healthineers).Main outcome measures: The main outcomes were sensitivity, specificity, and positive and negative predictive values of each self-test, with RT-PCR testing as the reference standard.Results: During phase 1, 45.0% (n=279) of participants in the Flowflex group, 29.1% (n=239) in the MPBio group, and 35.4% ((n=257) in the Clinitest group were confirmatory testers (previously tested positive by a self-test at own initiative). Overall sensitivities with nasal self-sampling were 79.0% (95% confidence interval 74.7% to 82.8%) for Flowflex, 69.9% (65.1% to 74.4%) for MPBio, and 70.2% (65.6% to 74.5%) for Clinitest. Sensitivities were substantially higher in confirmatory testers (93.6%, 83.6%, and 85.7%, respectively) than in those who tested for other reasons (52.4%, 51.5%, and 49.5%, respectively). Sensitivities decreased from 87.0% to 80.9% (P=0.16 by χ2test), 80.0% to 73.0% (P=0.60), and 83.1% to 70.3% (P=0.03), respectively, when transitioning from omicron accounting for 29% of infections to >95% of infections. During phase 2, 53.0% (n=288) of participants in the MPBio group and 44.4% (n=290) in the Clinitest group were confirmatory testers. Overall sensitivities with combined oropharyngeal and nasal self-sampling were 83.0% (78.8% to 86.7%) for MPBio and 77.3% (72.9% to 81.2%) for Clinitest. When combined oropharyngeal and nasal self-sampling was compared with nasal self-sampling, sensitivities were found to be slightly higher in confirmatory testers (87.4% and 86.1%, respectively) and substantially higher in those testing for other reasons (69.3% and 59.9%, respectively).Conclusions: Sensitivities of three rapid antigen tests with nasal self-sampling decreased during the emergence of omicron but was only statistically significant for Clinitest. Sensitivities appeared to be substantially influenced by the proportion of confirmatory testers. Sensitivities of MPBio and Clinitest improved after the addition of oropharyngeal to nasal self-sampling. A positive self-test result justifies prompt self-isolation without the need for confirmatory testing. Individuals with a negative self-test result should adhere to general preventive measures because a false negative result cannot be ruled out. Manufacturers of MPBio and Clinitest may consider extending their instructions for use to include combined oropharyngeal and nasal self-sampling, and other manufacturers of rapid antigen tests should consider evaluating this as well.

22 February 2023 in Science Translational Medicine
Verified
Journal Article
Open access
SAStijn P. Andeweg
Stijn P. Andeweg
HVHarry Vennema
Harry Vennema
IVIrene Veldhuijzen
Irene Veldhuijzen
NSNaomi Smorenburg
Naomi Smorenburg
DSDennis Schmitz
Dennis Schmitz
RGRIVM COVID-19 Molecular epidemiology group‡
RIVM COVID-19 Molecular epidemiology group‡
The extent to which severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) variants of concern (VOCs) break through infection- or vaccine-induced immunity is not well understood. We analyzed 28,578 sequenced SARS-CoV-2 samples from individuals with known immune status obtained through national community testing in the Netherlands from March to August 2021. We found evidence of an increased risk of infection by the Beta (B.1.351), Gamma (P.1), or Delta (B.1.617.2) variants compared with the Alpha (B.1.1.7) variant after vaccination. No clear differences were found between vaccines. However, the effect was larger in the first 14 to 59 days after complete vaccination compared with ≥60 days. In contrast to vaccine-induced immunity, there was no increased risk for reinfection with Beta, Gamma, or Delta variants relative to the Alpha variant in individuals with infection-induced immunity.

1 August 2019 in Journal of Hospital Infection
Verified
Journal Article
Open access
LTLara Tavoschi
Lara Tavoschi
LML. Mason
L. Mason
UPU. Petriti
U. Petriti
EBE. Bunge
E. Bunge
IVI. Veldhuijzen
I. Veldhuijzen
EDE. Duffell
E. Duffell
In the European Union/European Economic Area (EU/EEA) approximately 9 million people are chronically infected with hepatitis B virus (HBV) or hepatitis C virus (HCV), and many are undiagnosed. Targeted active case finding initiatives are needed. Iatrogenic transmission of HBV/HCV is relevant in Europe but people at risk of infection are often overlooked. This study aimed to identify groups at increased risk of HBV/HCV infection due to iatrogenic transmission, including healthcare workers, and to estimate incidence and prevalence. PubMed and Embase were systematically searched in February 2017 using strings combining terms for HBV/HCV, occurrence and population subgroups. All retrieved publications were screened and included articles were quality assessed. A predefined set of variables were extracted, and detailed summary tables were developed per population group of interest, virus and outcome. Thirty-eight articles were included, two reported on HBV, 22 on HCV and 16 on both, contributing 70 estimates of prevalence or incidence among: haemodialysis recipients, diabetes patients, recipients of substances of human origin, recipients of medical/dental procedures and healthcare workers. Estimates varied widely from 0.4% to 11.7% for HBV and from 0.7% to over 90% for HCV with most being higher than in the general population. Despite the limited number of studies retrieved, mostly old and focused on populations with multiple risk factors, our findings highlight the importance of considering population groups at higher risk for HBV/HCV iatrogenic transmission as target groups for active case finding in the EU/EEA. Test offers should be guided by individual risk assessment alongside local epidemiological data and local context.

24 October 2022 in BMC Medicine
Verified
Journal Article
Open access
PDF file
ESEwoud Schuit
Ewoud Schuit
RVRoderick P. Venekamp
Roderick P. Venekamp
IVIrene K. Veldhuijzen
Irene K. Veldhuijzen
WBWouter van Den Bijllaardt
Wouter van Den Bijllaardt
SPSuzan Pas
Suzan Pas
KMKarel G. M. Moons
Karel G. M. Moons
Background: The diagnostic accuracy of unsupervised self-testing with rapid antigen diagnostic tests (Ag-RDTs) is mostly unknown. We studied the diagnostic accuracy of a self-performed SARS-CoV-2 saliva and nasal Ag-RDT in the general population. Methods: This large cross-sectional study consecutively included unselected individuals aged $$\ge$$ ≥ 16 years presenting for SARS-CoV-2 testing at three public health service test sites. Participants underwent molecular test sampling and received two self-tests (the Hangzhou AllTest Biotech saliva self-test and the SD Biosensor nasal self-test by Roche Diagnostics) to perform themselves at home. Diagnostic accuracy of both self-tests was assessed with molecular testing as reference. Results: Out of 2819 participants, 6.5% had a positive molecular test. Overall sensitivities were 46.7% (39.3–54.2%) for the saliva Ag-RDT and 68.9% (61.6–75.6%) for the nasal Ag-RDT. With a viral load cut-off (≥ 5.2 log10 SARS-CoV-2 E-gene copies/mL) as a proxy of infectiousness, these sensitivities increased to 54.9% (46.4–63.3%) and 83.9% (76.9–89.5%), respectively. For the nasal Ag-RDT, sensitivities were 78.5% (71.1–84.8%) and 22.6% (9.6–41.1%) in those symptomatic and asymptomatic at the time of sampling, which increased to 90.4% (83.8–94.9%) and 38.9% (17.3–64.3%) after applying the viral load cut-off. In those with and without prior SARS-CoV-2 infection, sensitivities were 36.8% (16.3–61.6%) and 72.7% (65.1–79.4%). Specificities were > 99% and > 99%, positive predictive values > 70% and > 90%, and negative predictive values > 95% and > 95%, for the saliva and nasal Ag-RDT, respectively, in most analyses. Most participants considered the self-performing and result interpretation (very) easy for both self-tests. Conclusions: The Hangzhou AllTest Biotech saliva self Ag-RDT is not reliable for SARS-CoV-2 detection, overall, and in all studied subgroups. The SD Biosensor nasal self Ag-RDT had high sensitivity in individuals with symptoms and in those without prior SARS-CoV-2 infection but low sensitivity in asymptomatic individuals and those with a prior SARS-CoV-2 infection which warrants further investigation.