Wouter van Den Bijllaardt

Wouter van Den Bijllaardt

Auto-generated profile, based on publicly available information

Wouter van Den Bijllaardt

Microvida Laboratory for Medical Microbiology, Amphia Hospital, Breda, the Netherlands

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 July 2021 in BMJ
Verified
Journal Article
Open access
PDF file
ESEwoud Schuit
Ewoud Schuit
IVIrene K Veldhuijzen
Irene K Veldhuijzen
RVRoderick P Venekamp
Roderick P Venekamp
WBWouter van Den Bijllaardt
Wouter van Den Bijllaardt
SPSuzan Pas
Suzan Pas
KMKarel G M Moons
Karel G M Moons
Objective To assess the diagnostic test accuracy of two rapid antigen tests in asymptomatic and presymptomatic close contacts of people with SARS-CoV-2 infection on day 5 after exposure. Design Prospective cross sectional study. Setting Four public health service covid-19 test sites in the Netherlands. Participants 4274 consecutively included close contacts (identified through test-and-trace programme or contact tracing app) aged 16 years or older and asymptomatic for covid-19 when requesting a test. Main outcome measures Sensitivity, specificity, and positive and negative predictive values of Veritor System (Beckton Dickinson) and Biosensor (Roche Diagnostics) rapid antigen tests, with reverse-transcriptase polymerase chain reaction (RT-PCR) testing as reference standard. The viral load cut-off above which 95% of people with a positive RT-PCR test result were virus culture positive was used as a proxy of infectiousness. Results Of 2678 participants tested with Veritor, 233 (8.7%) had a RT-PCR confirmed SARS-CoV-2 infection of whom 149 were also detected by the rapid antigen test (sensitivity 63.9%, 95% confidence interval 57.4% to 70.1%). Of 1596 participants tested with Biosensor, 132 (8.3%) had a RT-PCR confirmed SARS-CoV-2 infection of whom 83 were detected by the rapid antigen test (sensitivity 62.9%, 54.0% to 71.1%). In those who were still asymptomatic at the time of sampling, sensitivity was 58.7% (51.1% to 66.0%) for Veritor (n=2317) and 59.4% (49.2% to 69.1%) for Biosensor (n=1414), and in those who developed symptoms were 84.2% (68.7% to 94.0%; n=219) for Veritor and 73.3% (54.1% to 87.7%; n=158) for Biosensor. When a viral load cut-off was applied for infectiouness (≥5.2 log10 SARS-CoV-2 E gene copies/mL), the overall sensitivity was 90.1% (84.2% to 94.4%) for Veritor and 86.8% (78.1% to 93.0%) for Biosensor, and 88.1% (80.5% to 93.5%) for Veritor and 85.1% (74.3% to 92.6%) for Biosensor, among those who remained asymptomatic throughout. Specificities were >99%, and positive and negative predictive values were >90% and >95%, for both rapid antigen tests in all analyses. Conclusions The sensitivities of both rapid antigen tests in asymptomatic and presymptomatic close contacts tested on day 5 onwards after close contact with an index case were more than 60%, increasing to more than 85% after a viral load cut-off was applied as a proxy for infectiousness.

2 July 2018 in Journal of Antimicrobial Chemotherapy
Verified
Journal Article
Open access
PDF file
WBWouter van Den Bijllaardt
Wouter van Den Bijllaardt
MSMaarten J Schijffelen
Maarten J Schijffelen
RBRon W Bosboom
Ron W Bosboom
JSJames Cohen Stuart
James Cohen Stuart
BDBram Diederen
Bram Diederen
AMAnouk E. Muller
Anouk E. Muller
Fosfomycin susceptibility testing is complicated and prone to error. Before using fosfomycin widely in patients with serious infections, acquisition of WT distribution data and reliable susceptibility testing methods are crucial. In this study, the performance of five methods for fosfomycin testing in the routine laboratory against the reference method was evaluated. Ten laboratories collected up to 100 ESBL-producing isolates each (80 Escherichia coli and 20 Klebsiella pneumoniae). Isolates were tested using Etest, MIC test strip (MTS), Vitek2, Phoenix and disc diffusion. Agar dilution was performed as the reference method in a central laboratory. Epidemiological cut-off values (ECOFFs) were determined for each species and susceptibility and error rates were calculated. In total, 775 E. coli and 201 K. pneumoniae isolates were tested by agar dilution. The ECOFF was 2 mg/L for E. coli and 64 mg/L for K. pneumoniae. Susceptibility rates based on the EUCAST breakpoint of ≤32 mg/L were 95.9% for E. coli and 87.6% for K. pneumoniae. Despite high categorical agreement rates for all methods, notably in E. coli, none of the alternative antimicrobial susceptibility testing methods performed satisfactorily. Due to poor detection of resistant isolates, very high error rates of 23.3% (Etest), 18.5% (MTS), 18.8% (Vitek2), 12.5% (Phoenix) and 12.9% (disc diffusion) for E. coli and 22.7% (Etest and MTS), 16.0% (Vitek2) and 12% (Phoenix) for K. pneumoniae were found. None of the methods adequately differentiated between WT and non-WT populations. Overall, it was concluded that none of the test methods is suitable as an alternative to agar dilution in the routine laboratory.

14 September 2022 in BMJ
Verified
Journal Article
Open access
PDF file
ESEwoud Schuit
Ewoud Schuit
RVRoderick P Venekamp
Roderick P Venekamp
LHLotty Hooft
Lotty Hooft
IVIrene K Veldhuijzen
Irene K Veldhuijzen
WBWouter van Den Bijllaardt
Wouter van Den Bijllaardt
KMKarel G M Moons
Karel G M Moons
Objective: To assess the performance of rapid antigen tests with unsupervised nasal and combined oropharyngeal and nasal self-sampling during the omicron period.Design: Prospective cross sectional diagnostic test accuracy study.Setting: Three public health service covid-19 test sites in the Netherlands, 21 December 2021 to 10 February 2022.Participants: 6497 people with covid-19 symptoms aged ≥16 years presenting for testing.Interventions: Participants had a swab sample taken for reverse transcription polymerase chain reaction (RT-PCR, reference test) and received one rapid antigen test to perform unsupervised using either nasal self-sampling (during the emergence of omicron, and when omicron accounted for >90% of infections, phase 1) or with combined oropharyngeal and nasal self-sampling in a subsequent (phase 2; when omicron accounted for >99% of infections). The evaluated tests were Flowflex (Acon Laboratories; phase 1 only), MPBio (MP Biomedicals), and Clinitest (Siemens-Healthineers).Main outcome measures: The main outcomes were sensitivity, specificity, and positive and negative predictive values of each self-test, with RT-PCR testing as the reference standard.Results: During phase 1, 45.0% (n=279) of participants in the Flowflex group, 29.1% (n=239) in the MPBio group, and 35.4% ((n=257) in the Clinitest group were confirmatory testers (previously tested positive by a self-test at own initiative). Overall sensitivities with nasal self-sampling were 79.0% (95% confidence interval 74.7% to 82.8%) for Flowflex, 69.9% (65.1% to 74.4%) for MPBio, and 70.2% (65.6% to 74.5%) for Clinitest. Sensitivities were substantially higher in confirmatory testers (93.6%, 83.6%, and 85.7%, respectively) than in those who tested for other reasons (52.4%, 51.5%, and 49.5%, respectively). Sensitivities decreased from 87.0% to 80.9% (P=0.16 by χ2test), 80.0% to 73.0% (P=0.60), and 83.1% to 70.3% (P=0.03), respectively, when transitioning from omicron accounting for 29% of infections to >95% of infections. During phase 2, 53.0% (n=288) of participants in the MPBio group and 44.4% (n=290) in the Clinitest group were confirmatory testers. Overall sensitivities with combined oropharyngeal and nasal self-sampling were 83.0% (78.8% to 86.7%) for MPBio and 77.3% (72.9% to 81.2%) for Clinitest. When combined oropharyngeal and nasal self-sampling was compared with nasal self-sampling, sensitivities were found to be slightly higher in confirmatory testers (87.4% and 86.1%, respectively) and substantially higher in those testing for other reasons (69.3% and 59.9%, respectively).Conclusions: Sensitivities of three rapid antigen tests with nasal self-sampling decreased during the emergence of omicron but was only statistically significant for Clinitest. Sensitivities appeared to be substantially influenced by the proportion of confirmatory testers. Sensitivities of MPBio and Clinitest improved after the addition of oropharyngeal to nasal self-sampling. A positive self-test result justifies prompt self-isolation without the need for confirmatory testing. Individuals with a negative self-test result should adhere to general preventive measures because a false negative result cannot be ruled out. Manufacturers of MPBio and Clinitest may consider extending their instructions for use to include combined oropharyngeal and nasal self-sampling, and other manufacturers of rapid antigen tests should consider evaluating this as well.

27 March 2020 in medRxiv
Verified
Preprint
Open access
PDF file
MKMarjolein Kluytmans
Marjolein Kluytmans
ABAnton G.M. Buiting
Anton G.M. Buiting
SPSuzan Pas
Suzan Pas
RBRobbert Bentvelsen
Robbert Bentvelsen
WBWouter van Den Bijllaardt
Wouter van Den Bijllaardt
JKJan A.J.W. Kluytmans
Jan A.J.W. Kluytmans
Background: On February 27, 2020, the first patient with COVID-19 was reported in the Netherlands. During the following weeks, nine healthcare workers (HCWs) were diagnosed with COVID-19 in two Dutch teaching hospitals, eight of whom had no history of travel to China or Northern-Italy. A low-threshold screening regimen was implemented to determine the prevalence and clinical presentation of COVID-19 among HCWs in these two hospitals. Methods: HCWs who suffered from fever or respiratory symptoms were voluntarily tested for SARS-CoV-2 by real-time reverse-transcriptase PCR on oropharyngeal samples. Structured interviews were conducted to document symptoms for all HCWs with confirmed COVID-19. Findings: Thirteen-hundred fifty-three (14%) of 9,705 HCWs employed were tested, 86 (6%) of whom were infected with SARS-CoV-2. Most HCWs suffered from relatively mild disease and only 46 (53%) reported fever. Eighty (93%) HCWs met a case definition of fever and/or coughing and/or shortness of breath. None of the HCWs identified through the screening reported a travel history to China or Northern Italy, and 3 (3%) reported to have been exposed to an inpatient known with COVID-19 prior to the onset of symptoms. Interpretation: Within two weeks after the first Dutch case was detected, a substantial proportion of HCWs with fever or respiratory symptoms were infected with SARS-CoV-2, probably caused by acquisition of the virus in the community during the early phase of local spread. The high prevalence of mild clinical presentations, frequently not including fever, asks for less stringent use of the currently recommended case-definition for suspected COVID-19. RESEARCH IN PERSPECTIVE: Evidence before this study: This study was conducted in response to the global spread of SARS-CoV-2, and the detection of eight healthcare workers (HCWs) in two Dutch teaching hospitals within two weeks after the first patient with COVID-19 was detected in the Netherlands who had no history of travel to China or Northern-Italy, raising the question of whether undetected community circulation was occurring. Added value of this study: To the best of our knowledge, this report is the first to describe the prevalence, the clinical presentation and early outcomes of COVID-19 in HCWs, which may be helpful for others seeking to identify HCWs suspected for COVID-19 in an outbreak situation. Implications of all the available evidence: We describe that within two weeks after the first Dutch case was detected, a substantial proportion of HCWs with fever or (mild) respiratory symptoms were infected with SARS-CoV-2, probably caused by acquisition of the virus in the community during the early phase of local spread. The high prevalence of mild clinical presentations, frequently not including fever, asks for less stringent use of the currently recommended case-definition for suspected COVID-19.

1 October 2020 in Clinical Microbiology and Infection
Verified
Journal Article
Open access
KZK. van der Zwaluw
K. van der Zwaluw
SWS. Witteveen
S. Witteveen
LWL. Wielders
L. Wielders
MSM. van Santen
M. van Santen
FLF. Landman
F. Landman
MWM.J.H.M. Wolfhagen
M.J.H.M. Wolfhagen
Carbapenem resistance mediated by mobile genetic elements has emerged worldwide and has become a major public health threat. To gain insight into the molecular epidemiology of carbapenem resistance in The Netherlands, Dutch medical microbiology laboratories are requested to submit suspected carbapenemase-producing Enterobacterales (CPE) to the National Institute for Public Health and the Environment as part of a national surveillance system. Meropenem MICs and species identification were confirmed by E-test and MALDI-TOF and carbapenemase production was assessed by the Carbapenem Inactivation Method. Of all submitted CPE, one species/carbapenemase gene combination per person per year was subjected to next-generation sequencing (NGS). In total, 1838 unique isolates were received between 2014 and 2018, of which 892 were unique CPE isolates with NGS data available. The predominant CPE species were Klebsiella pneumoniae (n = 388, 43%), Escherichia coli (n = 264, 30%) and Enterobacter cloacae complex (n = 116, 13%). Various carbapenemase alleles of the same carbapenemase gene resulted in different susceptibilities to meropenem and this effect varied between species. Analyses of NGS data showed variation of prevalence of carbapenemase alleles over time with blaOXA-48 being predominant (38%, 336/892), followed by blaNDM-1 (16%, 145/892). For the first time in the Netherlands, blaOXA-181, blaOXA-232 and blaVIM-4 were detected. The genetic background of K. pneumoniae and E. coli isolates was highly diverse. The CPE population in the Netherlands is diverse, suggesting multiple introductions. The predominant carbapenemase alleles are blaOXA-48 and blaNDM-1. There was a clear association between species, carbapenemase allele and susceptibility to meropenem.

24 October 2022 in BMC Medicine
Verified
Journal Article
Open access
PDF file
ESEwoud Schuit
Ewoud Schuit
RVRoderick P. Venekamp
Roderick P. Venekamp
IVIrene K. Veldhuijzen
Irene K. Veldhuijzen
WBWouter van Den Bijllaardt
Wouter van Den Bijllaardt
SPSuzan Pas
Suzan Pas
KMKarel G. M. Moons
Karel G. M. Moons
Background: The diagnostic accuracy of unsupervised self-testing with rapid antigen diagnostic tests (Ag-RDTs) is mostly unknown. We studied the diagnostic accuracy of a self-performed SARS-CoV-2 saliva and nasal Ag-RDT in the general population. Methods: This large cross-sectional study consecutively included unselected individuals aged $$\ge$$ ≥ 16 years presenting for SARS-CoV-2 testing at three public health service test sites. Participants underwent molecular test sampling and received two self-tests (the Hangzhou AllTest Biotech saliva self-test and the SD Biosensor nasal self-test by Roche Diagnostics) to perform themselves at home. Diagnostic accuracy of both self-tests was assessed with molecular testing as reference. Results: Out of 2819 participants, 6.5% had a positive molecular test. Overall sensitivities were 46.7% (39.3–54.2%) for the saliva Ag-RDT and 68.9% (61.6–75.6%) for the nasal Ag-RDT. With a viral load cut-off (≥ 5.2 log10 SARS-CoV-2 E-gene copies/mL) as a proxy of infectiousness, these sensitivities increased to 54.9% (46.4–63.3%) and 83.9% (76.9–89.5%), respectively. For the nasal Ag-RDT, sensitivities were 78.5% (71.1–84.8%) and 22.6% (9.6–41.1%) in those symptomatic and asymptomatic at the time of sampling, which increased to 90.4% (83.8–94.9%) and 38.9% (17.3–64.3%) after applying the viral load cut-off. In those with and without prior SARS-CoV-2 infection, sensitivities were 36.8% (16.3–61.6%) and 72.7% (65.1–79.4%). Specificities were > 99% and > 99%, positive predictive values > 70% and > 90%, and negative predictive values > 95% and > 95%, for the saliva and nasal Ag-RDT, respectively, in most analyses. Most participants considered the self-performing and result interpretation (very) easy for both self-tests. Conclusions: The Hangzhou AllTest Biotech saliva self Ag-RDT is not reliable for SARS-CoV-2 detection, overall, and in all studied subgroups. The SD Biosensor nasal self Ag-RDT had high sensitivity in individuals with symptoms and in those without prior SARS-CoV-2 infection but low sensitivity in asymptomatic individuals and those with a prior SARS-CoV-2 infection which warrants further investigation.