31 December 2020 in Journal of Power System Engineering
Cryopump, which is the removal of gas from a system by solidification onto a cold space, is an ideal form of ultra high vacuum pump due to its contamination-free operation at its highest pumping speed. With high crossover capability and high throughput, the cryopump can provide clean vacuum environment. Since the cryopump creates a vacuum state by condensation and adsorption mechanisms, a multi-stage cryocooler is imperative. This research focuses on the development of a 2-stage GM (Gifford-McMahon) cryocooler utilized for a large capacity cryopump. By taking simple computation on two different regenerator, it is possible to predict the cooling performance of the GM cryocooler. As a working fluid, helium is supplied by a helium compressor with the electric consumption of 2.4 kW. The operational frequency of GM cryocooler is set to be 1.2 Hz (72 rpm). Although the second stage regenerator has a little bit more thermal loss than expected, the experiment results show that the design methodology is able to adequately explain the thermal characteristic of the GM cryocooler. The developed 2-stage GM cryocooler can exert the cooling power of 40.04 W at 80 K and 5.36 W at 20 K, simultaneously.
31 December 2021 in Journal of Power System Engineering
This paper describes a performance test of Stirling cooler developed for ultra-low temperature application. A Stirling cooler has advantages of low GWP refrigerant, high efficiency and wide operating range compared with conventional ultra low temperature refrigerator. In this research, the Stirling cooler driven by a linear compressor is developed and the cooling performance test is performed at -100°C and -150°C. In cooling performance test, the input voltage is adjusted in the range from 150 to 210 Vrms. With the measured data, it is investigated the dynamic behavior and cooling performance of the developed Stirling cooler. The developed cooler shows 362 W of cooling capacity and 0.480 of COP at -100°C. At -150°C of the cold-end temperature, the cooling capacity and COP are 159 W and 0.186, respectively.
31 December 2021 in Journal of Power System Engineering
This paper describes the performance test of a helium scroll compressor originally used for Gifford-McMahon (GM) cryocooler. This compressor can also be used for the reverse Brayton cryogenic refrigeration system. In this paper, the performance characteristics of a scroll compressor is experimentally investigated with helium and neon gas to obtain reference data for designing thermodynamic cycle of cryogenic refrigeration system. To maintain constant suction pressure during experiments, an experimental setup contains pressure regulation system which consists of three control valves and gas buffer. Pressures, mass flow rate and power consumption are measured for 400, 450, 500, 550 kPa of suction pressure condition. With experimental measurements, performance characteristics of a helium scroll compressor is investigated. The tested scroll compressor shows the higher isentropic efficiency with helium as a working gas than neon.
31 December 2022 in Journal of Power System Engineering
This research paper handles fabrication and testing issues during localization of a 20-inch cryopump. The developed cryopump is equipped with a two-stage GM (Gifford- McMahon) cryocooler. The GM cryocooler can absorb heat of 80.21 W and 8.05 W at each stage under the temperature of 69.59 K and 17.98 K, respectively. At this time, The electric consumption is recorded to be 5.77 kW. Reliability test on the GM cryocooler is also being conducted to secure track-record in commercializing the developed cryopump (currently 6,500 hours passed). For the cryopump, using nitrogen gas, the ultimate pressure and pumping speed are measured to be 9.07×10SUP-9/SUP mbar and 11,473 L/s.
31 October 2022 in Journal of Power System Engineering
This paper describes cooling performance test of a high capacity ultra-low temperature stirling cooler for semiconductor manufacturing process. A stirling cooler has the better efficiency and reliability compare with a conventional vapor-compression refrigerator at ultra low temperature around -100℃. Moreover, it uses helium gas as a refrigerant, of which GWP is zero. In this study, a gamma-type stirling cooler driven by a double-acting linear compressor is developed and tested. From experiments, the developed stirling cooler reaches from room temperature to -100℃ within 10 minutes. The cooling capacity and electric input power are measured for a wide range of input voltages, and it shows 0.39 to 1.75 kW of cooling capacity and 0.282 to 0.358 of COP at -100℃ of cold-end temperature.