Given that REBCO wire is typically manufactured as a tape, it is possible for REBCO magnets to exhibit a relatively larger screening current-induced field (SCF). It is well known that the SCF in an REBCO magnet can be effectively reduced by the so-called current sweep method. However, it requires an overshooting in the magnet current, often close to the magnet's critical current, to effectively suppress the SCF, which may not be favored in terms of operation reliability. In this study, we experimentally validated an alternative approach which mitigates the SCF using thermal cycling together with the current sweep reversal. Well known is the fact that the large load factor, defined as the ratio of operating current to critical current of an REBCO magnet, deteriorates the SCF impact on field uniformity. The key idea is to increase the magnet temperature to increase the effective load factor of the magnet close to its quench limit momentarily, minimize the SCF, and then return back to the nominal operating condition. The combined approach of the thermal cycling and the current sweep may be effective when attempting to eliminate the SCF without ramping an REBCO magnet to a current that may be dangerously high, especially when the magnet is operated at a high operating current. This paper presents the test results of the combined approach in the conduction-cooled REBCO magnet, and the results demonstrate the potential of the approach for more safe and effective elimination of the SCF.
31 December 2021 in Journal of Power System Engineering
This paper describes the performance test of a helium scroll compressor originally used for Gifford-McMahon (GM) cryocooler. This compressor can also be used for the reverse Brayton cryogenic refrigeration system. In this paper, the performance characteristics of a scroll compressor is experimentally investigated with helium and neon gas to obtain reference data for designing thermodynamic cycle of cryogenic refrigeration system. To maintain constant suction pressure during experiments, an experimental setup contains pressure regulation system which consists of three control valves and gas buffer. Pressures, mass flow rate and power consumption are measured for 400, 450, 500, 550 kPa of suction pressure condition. With experimental measurements, performance characteristics of a helium scroll compressor is investigated. The tested scroll compressor shows the higher isentropic efficiency with helium as a working gas than neon.
16 September 2025 in IEEE Transactions on Applied Superconductivity
In this paper, we present a method for determining the appropriate charging current waveform to mitigate the screening-current-induced field (SCF) in an NMR class HTS magnet. It has been observed that screening currents degrade the magnetic field quality of NMR class HTS magnets, and the extent of this degradation varies depending on the charging current waveform. We developed a simulation program to predict the effects of screening currents when applying specific charging current waveforms to given HTS magnets. Using the program, we were able to determine which current waveforms are most suitable for a given HTS magnet. To validate the performance of the program, we applied the same current waveforms to the actual NMR class HTS magnet and measured the central magnetic field. We compared the experimental results with the simulations and confirmed that they were nearly identical. This technique is expected to allow us to determine the most suitable charging current waveform for reducing screening currents before conducting time-consuming and resource-intensive charging experiments.
31 December 2020 in Journal of Power System Engineering
Cryopump, which is the removal of gas from a system by solidification onto a cold space, is an ideal form of ultra high vacuum pump due to its contamination-free operation at its highest pumping speed. With high crossover capability and high throughput, the cryopump can provide clean vacuum environment. Since the cryopump creates a vacuum state by condensation and adsorption mechanisms, a multi-stage cryocooler is imperative. This research focuses on the development of a 2-stage GM (Gifford-McMahon) cryocooler utilized for a large capacity cryopump. By taking simple computation on two different regenerator, it is possible to predict the cooling performance of the GM cryocooler. As a working fluid, helium is supplied by a helium compressor with the electric consumption of 2.4 kW. The operational frequency of GM cryocooler is set to be 1.2 Hz (72 rpm). Although the second stage regenerator has a little bit more thermal loss than expected, the experiment results show that the design methodology is able to adequately explain the thermal characteristic of the GM cryocooler. The developed 2-stage GM cryocooler can exert the cooling power of 40.04 W at 80 K and 5.36 W at 20 K, simultaneously.
31 December 2021 in Journal of Power System Engineering
This paper describes a performance test of Stirling cooler developed for ultra-low temperature application. A Stirling cooler has advantages of low GWP refrigerant, high efficiency and wide operating range compared with conventional ultra low temperature refrigerator. In this research, the Stirling cooler driven by a linear compressor is developed and the cooling performance test is performed at -100°C and -150°C. In cooling performance test, the input voltage is adjusted in the range from 150 to 210 Vrms. With the measured data, it is investigated the dynamic behavior and cooling performance of the developed Stirling cooler. The developed cooler shows 362 W of cooling capacity and 0.480 of COP at -100°C. At -150°C of the cold-end temperature, the cooling capacity and COP are 159 W and 0.186, respectively.