Arnaldo Alves Cardoso

Arnaldo Alves Cardoso

Auto-generated profile, based on publicly available information

Arnaldo Alves Cardoso

São Paulo State University, Department of Analytical Chemistry, UNESP, CEP 14800-970, Araraquara, SP, Brazil

Research Focus & Metrics

Academic Career Length

37Years (1990-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 January 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
DMDanilo Manzani
Danilo Manzani
João Flávio Da Silveira PetruciJoão Flávio Da Silveira Petruci
João Flávio Da Silveira Petruci
KNKarina Nigoghossian
Karina Nigoghossian
ACArnaldo Alves Cardoso
Arnaldo Alves Cardoso
SRSidney Ribeiro
Sidney Ribeiro
The determination of temperature is essential in many applications in the biomedical, technological, and industrial fields. Optical thermometry appears to be an excellent alternative for conventional electric temperature sensors because it is a non-contact method that offers a fast response, electromagnetic passivity, and high temperature sensitivity. In this paper, we propose an optical thermometer probe comprising an Er3+/Yb3+ co-doped tellurite glass attached to the tip of an optical fibre and optically coupled to a laser source and a portable USB spectrometer. The ratio of the up-conversion green emission integrated peak areas when excited at 980 nm was temperature dependent, and it was used to calibrate the thermometer. The thermometer was operated in the range of 5–50 °C and 50–200 °C, and it revealed excellent linearity (r2 > 0.99), suitable accuracy, and precisions of ±0.5 and ±1.1 °C, respectively. By optimizing Er3+ concentration, we could obtain the high green emission intensity, and in turn, high thermal sensitivity for the probe. The probe fabricated in the study exhibited suitable properties for its application as a temperature sensor and superior performance compared to other Er3+ -based optical thermometers in terms of thermal sensitivity.

1 December 2012 in Atmospheric Environment
Verified
Journal Article
Closed access
RURoberta Cerasi Urban
Roberta Cerasi Urban
MLMichele Lima-Souza
Michele Lima-Souza
LCLetícia Caetano-Silva
Letícia Caetano-Silva
MQMaria Eugênia Costa Queiroz
Maria Eugênia Costa Queiroz
RNRaquel F.P. Nogueira
Raquel F.P. Nogueira
MCMaria Lucia A.M. Campos
Maria Lucia A.M. Campos

1 February 2014 in Atmospheric Environment
Verified
Journal Article
Closed access
KSKely F. Souza
Kely F. Souza
LCLilian R.F. Carvalho
Lilian R.F. Carvalho
AAAndrew G. Allen
Andrew G. Allen
ACArnaldo A. Cardoso
Arnaldo A. Cardoso

1 September 2004 in Atmospheric Environment
Verified
Journal Article
Closed access
AAA.G. Allen
A.G. Allen
ACA.A. Cardoso
A.A. Cardoso
GRG.O. da Rocha
G.O. da Rocha

25 October 2013 in The Analyst
Verified
Journal Article
Closed access
PDF file
João Flávio Da Silveira PetruciJoão Flávio Da Silveira Petruci
João Flávio Da Silveira Petruci
PFPaula Regina Fortes
Paula Regina Fortes
VKVjekoslav Kokoric
Vjekoslav Kokoric
AWAndreas Wilk
Andreas Wilk
IRIvo Milton Raimundo
Ivo Milton Raimundo
BMBoris Mizaikoff
Boris Mizaikoff
Hydrogen sulfide is a highly corrosive, harmful, and toxic gas produced under anaerobic conditions within industrial processes or in natural environments, and plays an important role in the sulfur cycle. According to the U.S. Occupational Safety and Health Administration (OSHA), the permissible exposure limit (during 8 hours) is 10 ppm. Concentrations of 20 ppm are the threshold for critical health issues. In workplace environments with human subjects frequently exposed to H2S, e.g., during petroleum extraction and refining, real-time monitoring of exposure levels is mandatory. Sensors based on electrochemical measurement principles, semiconducting metal-oxides, taking advantage of their optical properties, have been described for H2S monitoring. However, extended response times, limited selectivity, and bulkiness of the instrumentation are common disadvantages of the sensing techniques reported to date. Here, we describe for the first time usage of a new generation of compact gas cells, i.e., so-called substrate-integrated hollow waveguides (iHWGs), combined with a compact Fourier transform infrared (FTIR) spectrometer for advanced gas sensing of H2S. The principle of detection is based on the immediate UV-assisted conversion of the rather weak IR-absorber H2S into much more pronounced and distinctively responding SO2. A calibration was established in the range of 10–100 ppm with a limit of detection (LOD) at 3 ppm, which is suitable for occupational health monitoring purposes. The developed sensing scheme provides an analytical response time of less than 60 seconds. Considering the substantial potential for miniaturization using e.g., a dedicated quantum cascade laser (QCL) in lieu of the FTIR spectrometer, the developed sensing approach may be evolved into a hand-held instrument, which may be tailored to a variety of applications ranging from environmental monitoring to workplace safety surveillance, process analysis and clinical diagnostics, e.g., breath analysis.

9 February 2022 in TrAC Trends in Analytical Chemistry
Verified
Journal Article
Closed access
JPJoão Flávio da Silveira Petruci
João Flávio da Silveira Petruci
DBDiandra Nunes Barreto
Diandra Nunes Barreto
MDMariana A. Dias
Mariana A. Dias
EFErika P. Felix
Erika P. Felix
ACArnaldo A. Cardoso
Arnaldo A. Cardoso