Shixun Pei

Shixun Pei

Auto-generated profile, based on publicly available information

Shixun Pei

MOE Key Laboratory of Fundamental Physical Quantities Measurement, Hubei Key Laboratory of Gravitation and Quantum Physics, PGMF, School of Physics, Huazhong University of Science and Technology 1 , Wuhan 430074, China

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2021 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
SHShuang Hu
Shuang Hu
SPShixun Pei
Shixun Pei
MHMing Hu
Ming Hu
YBYanzheng Bai
Yanzheng Bai
HLHongyin Li
Hongyin Li
ZZZebing Zhou
Zebing Zhou
A high precision electrostatic accelerometer has widely been employed to measure gravity gradients and detect gravitational waves in space. The high-voltage levitation method is one of the solutions for testing electrostatic accelerometers on the ground, which aims at simultaneously detecting all six-degree-of-freedom movements of the electrostatic accelerometers engineering and flight prototypes. However, the noise performance in the high-voltage levitation test is mainly limited by seismic noise. The combined test of the accelerometer and vibration isolation platform is adopted to improve the detection precision of the high-voltage levitation method. In this paper, a high precision electrostatic accelerometer prototype is developed after designed appropriate mechanical parameters with a test mass weighing 300 g and with an estimated resolution of 2 × 10−12 m/s2/Hz1/2 from 0.01 to 0.4 Hz. Such a prototype is tested by the high-voltage levitation method, its measurement noise on the ground is mainly limited by the seismic noise, which is about 5 × 10−7 m/s2/Hz1/2 around 0.2 Hz and about 4 × 10−8 m/s2/Hz1/2 around 0.1 Hz. A vibration isolation pendulum bench based on the translation–tilt compensation principle is adopted for accelerometer prototype combined tests to suppress the seismic noise, which has a large bench area and the ability to adjust the tilt angle precisely. The measured accelerometer noise of the combined test with the translation–tilt compensation pendulum has reached 3 × 10−9 m/s2/Hz1/2 around 0.2 Hz, and it is about two orders of magnitude lower than the measurement noise on the ground. The combined test method provides technical guidance for further improving the noise level of ground test in the future.

12 November 2019 in Classical and Quantum Gravity
Verified
Journal Article
Closed access
SPS X Pei
S X Pei
LLL Liu
L Liu
SWS C Wu
S C Wu
YBYanzheng Bai
Yanzheng Bai
ZZZ B Zhou
Z B Zhou
A low-frequency vibration insensitive accelerometer test pendulum bench based on translation-tilt compensation for testing a high precise accelerometer has been proposed in order to suppress the effect of seismic noise. However, the seismic noise suppression could be affected by the high-frequency coupling due to possible nonlinearities and the cross-coupling due to the off-axis location of the accelerometers on the bench. In this paper, based on the basic vibration insensitive design and actual application requirement, the location effect of the accelerometer on the bench is firstly modeled and analyzed, and then the adjustment schemes combined with the center of percussion concept to suppress these coupling effects are presented. Finally, the analytical result and the adjustment scheme are verified by an experimental demonstration.

8 November 2025 in Acta Astronautica
Verified
Journal Article
Closed access
FYFangchao Yang
Fangchao Yang
SPShixun Pei
Shixun Pei
WHWei Hong
Wei Hong

1 January 2025 in Shock and Vibration
Verified
Journal Article
Open access
SPShixun Pei
Shixun Pei
FYFangchao Yang
Fangchao Yang
ZWZhenhua Wen
Zhenhua Wen
Seismic noise is a major limitation for high‐precision electrostatic accelerometer performance investigation on the ground. Various pendulums were developed to isolate the seismic noise, and the translation–tilt compensation pendulum is a new low‐frequency passive horizontal vibration isolation pendulum. But the test level of the accelerometers mounted on the pendulum bench is influenced by the cross‐coupling from the rotational axis of the bench. In this study, we discuss the influence of the torsional behavior of the translation–tilt compensation pendulum in depth and propose a suppression scheme based on a novel “four‐wire” suspension structure. An experimental platform was developed to validate the theoretical analysis and examine the vibration isolation performance. The results show that the acceleration noise of the pendulum with “four‐wire” suspension structure reached 2 × 10 −9 m/s 2 /Hz 1/2 around 0.1 Hz which is usually the working frequency band of the accelerometer. This result is two orders of magnitude lower than the previous noise level. The seismic noise suppression of the translation–tilt compensation pendulum is improved, and the frequency band of vibration isolation is expanded. The pendulum can be applied in more precise experiments that are required to suppress seismic noise.

25 July 2026 in Measurement
Verified
Journal Article
Closed access
SPShixun Pei
Shixun Pei
LSLong Su
Long Su
WHWei Hong
Wei Hong
FYFangchao Yang
Fangchao Yang
ZLZhenglan Liang
Zhenglan Liang
ZWZhenhua Wen
Zhenhua Wen