Hisatomo Kondo

Hisatomo Kondo

Auto-generated profile, based on publicly available information

Hisatomo Kondo

Department of Fixed Prosthodontics and Oral Implantology, School of Dentistry Aichi Gakuin University Nagoya Japan

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2017 in Journal of Prosthodontic Research
Verified
Journal Article
Open access
SFShota Fukazawa
Shota Fukazawa
COChikayuki Odaira
Chikayuki Odaira
HKHisatomo Kondo
Hisatomo Kondo
We examined the accuracy, including trueness and precision, of the intraoral scanners comparing with laboratory scanner to reveal the error level of intraoral scanners. Measurements were performed using a computer numerical control coordinate measuring machine (CNCCMM) of the reference models as a control. Subsequently, intraoral scanners and a laboratory scanner were used for measurements of the reference trueness and precision of the distance were evaluated by image analyzing software. With regard to reference model, there was a significant difference between in the trueness measured by C.O.S. (COS) and that measured by the other scanners. The trueness measured by the second-generation 3M™ true definition scanner (TDS2) and third-generation 3M™ true definition scanner (TDS3) was bigger than the one by TRIOS (TR) and KaVo (KA). With regard to reference model "B," error of the trueness measured by COS was significantly bigger, compared with the one measured by the other scanners. However, error range of intraoral scanners, except for COS, was considerably small and it should be covered with cement space. The results of this study indicated that an optical impression method with an intraoral scanner could be applied to the implant therapy for multiple teeth missing.

13 April 2022 in International Journal of Implant Dentistry
Verified
Journal Article
Open access
PDF file
RNReiji Natsubori
Reiji Natsubori
SFShota Fukazawa
Shota Fukazawa
TCToyokazu Chiba
Toyokazu Chiba
NTNorimasa Tanabe
Norimasa Tanabe
HKHidemichi Kihara
Hidemichi Kihara
HKHisatomo Kondo
Hisatomo Kondo
Background: The purpose of this study was to evaluate the accuracy of intraoral scanners by comparing the trueness and precision of several types of scanners in measuring the distance between the ball abutments on pairs of multiple implants.Methods: Seven implants were placed on a fully edentulous upper jaw model. After ball abutments were attached to the implants on the master model, the three-dimensional (3D) shape of the model was evaluated using a computer numerical control 3D coordinate-measuring machine. Subsequently, the 3D shape-related data of the model were obtained using two types of intraoral scanners (3M True Definition Scanner [TDS] and 3Shape Trios3 [TR3]) and two types of laboratory scanners (KaVo ARCTICA Auto Scan [KA] and Identica Hybrid [IH]). Using the obtained 3D shape-related data, the trueness and precision in measuring the distance between the balls within seven pairs of ball abutments were compared among the scanners using 3D analysis software.Results: Intraoral scanners produced significantly greater errors in trueness and precision than laboratory scanners in measuring the distances between the ball abutments in all the dental regions. Between the intraoral scanners, powder-requiring TDS produced significantly lower errors at inflection points than powder-free TR3.Conclusions: These results indicate that an optical impression technique using an intraoral scanner is suitable for dental implant treatment in patients with a few missing teeth.

25 February 2016 in International Journal of Molecular Medicine
Verified
Journal Article
Open access
PDF file
YIYasuyuki Igarashi
Yasuyuki Igarashi
NCNaoyuki Chosa
Naoyuki Chosa
SSShunsuuke Sawada
Shunsuuke Sawada
HKHisatomo Kondo
Hisatomo Kondo
TYTakashi Yaegashi
Takashi Yaegashi
AIAkira Ishisaki
Akira Ishisaki
The direction of mesenchymal stem cell (MSC) differentiation is regulated by stimulation with various growth factors and cytokines. We recently established MSC lines, [transforming growth factor-β (TGF-β)-responsive SG‑2 cells, bone morphogenetic protein (BMP)-responsive SG‑3 cells, and TGF-β/BMP-non-responsive SG‑5 cells], derived from the bone marrow of green fluorescent protein-transgenic mice. In this study, to compare gene expression profiles in these MSC lines, we used DNA microarray analysis to characterize the specific gene expression profiles observed in the TGF-β-responsive SG‑2 cells. Among the genes that were highly expressed in the SG‑2 cells, we focused on vascular endothelial growth factor (VEGF) receptor 3 (VEGFR3), the gene product of FMS-like tyrosine kinase 4 (Flt4). We found that VEGF-C, a specific ligand of VEGFR3, significantly induced the cell proliferative activity, migratory ability (as shown by Transwell migration assay), as well as the phosphorylation of extracellular signal-regulated kinase (ERK)1/2 in the SG‑2 cells. Additionally, VEGF-C significantly increased the expression of prospero homeobox 1 (Prox1) and lymphatic vessel endothelial hyaluronan receptor 1 (Lyve1), which are lymphatic endothelial cell markers, and decreased the expression of osteogenic differentiation marker genes in these cells. By contrast, TGF-β significantly increased the expression of early-phase osteogenic differentiation marker genes in the SG‑2 cells and markedly decreased the expression of lymphatic endothelial cell markers. The findings of our study strongly suggest the following: i) that VEGF-C promotes the proliferative activity and migratory ability of MSCs; and ii) VEGF-C and TGF-β reciprocally regulate MSC commitment to differentiation into lymphatic endothelial or osteoblastic phenotypes, respectively. Our findings provide new insight into the molecular mechanisms underlying the regenerative ability of MSCs.

1 March 2019 in Journal of Nanobiotechnology
Verified
Journal Article
Open access
PDF file
TNToshiki Nojiri
Toshiki Nojiri
CCChia-Yu Chen
Chia-Yu Chen
DKDavid M. Kim
David M. Kim
John D Da SilvaJohn D Da Silva
John D Da Silva
CLCliff Lee
Cliff Lee
MNMasazumi Nagai
Masazumi Nagai
Natural teeth are supported by connective tissue collagen fibers that insert perpendicularly in the tooth cementum. Perpendicular insertion plays an important role in the maintenance of the junction between the oral epithelium and the periodontal connective tissue. Most titanium dental implant surfaces have no micro or macro structure to support perpendicularly oriented collagen attachment. Without this tight biologic seal to resist bacterial invasion and epithelial downgrowth, progressive bone loss in peri-implantitis is seen around dental implants. The purpose of this study was to establish the perpendicularly oriented collagen attachment to titanium oxide nanotube (TNT), and to assess its binding stability. TNT was prepared on the titanium-surface by anodization. Scanning electron microscopy (SEM) showed a regularly aligned TNT with an average 67 nm-diameter when anodized at 30 V for 3 h. Subsequently, collagen type I (CoI) was electrophoretically fused to anodic TNT in native polyacrylamide gel system where negatively charged CoI-C term was perpendicularly navigated to TNT. SEM and atomic force microscopy (AFM) were used to analyze CoI on the TiO2 and TNT surface. Several tens of nanometers of CoI protrusion were recorded by AFM. These protrusions may be long enough to be priming sites for cell-secreted CoI. CoI laid parallel to the titanium surface when fused by a chemical linker. Binding resistance of CoI against drastic ultrasonication was measured by Fourier-transform infrared spectroscopy attenuated total reflection (FTIR-ATR). The electrophoretically fused CoI in the titanium nanotube (TNT–CoIEPF) showed the significantly greatest binding resistance than the other groups (P < 0.01, a 1-way ANOVA and Tukey HSD post hoc test). Furthermore, TNT–CoIEPF surface rejected epithelial cell stretching and epithelial sheet formation. Chemically linked horizontal CoI on titanium oxide (TiO2) facilitated epithelial cell stretching and sheet formation.

31 January 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
KOKei Onodera
Kei Onodera
IMIkuya Miyamoto
Ikuya Miyamoto
IHIsao Hoshi
Isao Hoshi
SKShinsuke Kawamata
Shinsuke Kawamata
NTNoriaki Takahashi
Noriaki Takahashi
HYHiroyuki head and Yamada
Hiroyuki head and Yamada
The purpose of this retrospective study was to evaluate computer-assisted virtual surgery and the outcomes of mandibular reconstruction using an autogenous particulate cancellous bone and marrow (PCBM) graft combined with a custom-made titanium mesh (TiMesh) using a three-dimensional (3D) printing model. Eighteen consecutive patients were included, and preoperative virtual simulation surgery was performed using digital data. Segmental bone defects showed deviation of the mandible due to displacement of the condyle and segments, unnatural length of the mandibular body, or poorer intermaxillary relationship compared to the marginal bone defect caused by previous operations. These mandibular disharmonies could be simulated, and virtual surgery was performed on a computer with adjustment of displaced mandibular segments, length of the mandibular body, and dental arch with digital bone augmentation. TiMesh was manually pre-bent using a 3D printing model, and PCBM from the iliac crest was grafted with TiMesh. The short-term clinical results were good; reconstruction of the alveolar crest was prosthetically desirable; and minor complications were observed. In conclusion, virtual reconstruction is crucial for treating complex deviated mandibles. Accurate condylar and dental arch positions with an optimum mandibular length are important for prosthetically satisfactory mandibular reconstruction.

1 January 2023 in Journal of Prosthodontic Research
Verified
Journal Article
Open access
PDF file
MOMami Okamoto
Mami Okamoto
NTNorimasa Tanabe
Norimasa Tanabe
SFShota Fukazawa
Shota Fukazawa
YOYutaro Oyamada
Yutaro Oyamada
HKHisatomo Kondo
Hisatomo Kondo
Purpose: This study aimed to clarify the effect of occlusal force on appropriate optical interocclusal registration in clinical practice, considering periodontal ligament and jawbone deformation.Methods: Forty participants with natural, healthy dentition were enrolled (19 men and 21 women; mean age, 27.7 ± 2.0 years). A TRIOS3 intraoral scanner was used to scan the right lateral first premolar to the second molar areas of the upper and lower jaws. During scanning for interocclusal registration, participants were instructed to “bite normally,” “bite lightly,” and “bite strongly” to obtain data for the three occlusal patterns. The standard triangulated language (STL) data for each occlusion condition were superimposed using the appropriate software, following which the tooth displacement was calculated. The conventional method was also used to record the occlusal contact area for a silicone model using a dental contact analyzer.Results: Tooth displacement was significantly lower for the strong-bite condition than for the weak-bite condition (0.018 mm vs. 0.028 mm, P<0.05). As the occlusal force increased, the occlusal contact area also increased, and significant differences were observed among the different occlusal conditions (P<0.05).Conclusions: Occlusal contact area changed depending on the bite force when using the silicone impression or optical intraoral scanning methods. Moreover, using optical impression methods in “strong bite force” may reduce the deviation and allow for stable interocclusal registration.