20 July 2021 in IEEE Transactions on Geoscience and Remote Sensing
Aeromagnetic noise compensation is a vital part of aerial survey measurement, and its compensation effect directly determines the quality of aeromagnetic survey data. At present, the commonly used compensation model is the T-L model, and the least squares method is used to solve for the coefficients. However, the noise source modeled in the T-L model is incomplete. Since the tail boom cannot be completely rigid, tail-boom swing is an unavoidable problem in aeromagnetic measurement. This kind of swing is the most obvious when the aircraft is maneuvering, and it will significantly interfere with the measurement data of the sensor. In this article, two causes of the swing noise are analyzed, and the nonlinear relationship between the swing displacement and the noise is derived. Since it is difficult to express the nonlinear relationship with mathematical forms to compensate for the aeromagnetic data, we propose a new compensation method that uses a 1-D convolutional neural network to perform secondary compensation on the data already compensated by the T-L model in order to remove the effect of tail-boom swing. The flight experiment data show that the proposed method can significantly improve the quality of aeromagnetic data. Compared with the T-L method, the improve ratio is increased by 60%–100%. It shows that the proposed method has a remarkable compensation effect for aeromagnetic noise.
23 June 2021 in IEEE Transactions on Instrumentation and Measurement
The coils in a three-axis fluxgate magnetometer have been investigated to enhance the noise and power performance for the use in geomagnetic stations. The turn number of the excitation and pickup coils in the fluxgate sensors is carefully optimized by measuring the equivalent magnetic noise spectral density of the magnetometers. Correspondingly, the values of the tuning and demodulation capacitors are delicately designed to match the optimized coils. The noise of the fluxgate magnetometer is 6 pT/ √Hz at 1 Hz with a power consumption lower than 360 mW. The size of the packaged magnetometer is 30 ×30 ×113 mm 3 , and its weight is less than 80 g (without cable). The features of the fluxgate magnetometer make it a suitable instrument for geomagnetic stations and other applications.
19 February 2024 in IEEE Sensors Journal
Fluxgate is a vectorial magnetic sensor that enables measure the quasi-static and low-frequency ac magnetic field by demodulating the variations near the excitation harmonics. Based on advantages such as high sensitivity and small volume, fluxgate sensor is widely used for the geo-physical mapping, mineral explorations, risk mitigations and other applications. Fluxgate sensors measure the magnetic fields basing on the nonlinearity and symmetry on the magnetization hysteresis curve of ferromagnetic materials. Therefore, the performance of the fluxgate sensor largely depends on the performance of the magnetic core material. In this work, the internal stress of the Co-base amorphous wire core, the impedance of the coil that is tightly wound around the core, the sensitivity and the noise level of the sensor are discussed, expressed and experimental proofed with various annealing temperatures on the amorphous wires. The experimental results show that the derived relationships between the properties in materials and performances of sensors in this paper are correct and effective. In conclusion, by measuring the impedance of the core and coils, it could be predicted the optimum performances for fluxgate sensors and guide the sensor fabrications.
16 June 2023 in IEEE Transactions on Geoscience and Remote Sensing
TRThorkild Maack Rasmussen
+2
The transient electromagnetic (TEM) method utilizes artificial transmitters and measures electromagnetic responses to reveal the resistivity information of the subsurface. The current waveform of transmitters has non-negligible effects on induced fields. Therefore, 3-D TEM forward modelling algorithms need the capability of simulating arbitrary waveforms to obtain accurate responses. In time-stepping-based 3-D TEM forward modelling, the source term approach is frequently used, which employs the source current density to model the waveform variation during time-stepping. The source term approach, however, requires fine-time discretization to describe complex waveforms, which could significantly raise the computational cost. We present a robust convolution approach that computes the convolution between the time derivative of the waveform and the step-off response to incorporate the waveform effects in 3-D TEM modelling. The convolution approach does not discretize the waveform using time steps. Hence, it is advantageous when modelling full-waveform cases. The developed algorithm is based on the finite-element method using unstructured grids and the implicit backward Euler approach. Both galvanic and inductive transmitters are incorporated. Ground and airborne TEM surveys are tested using an actual airborne TEM waveform, a full waveform of the 2( n )-sequence pseudo-random signal, and various synthetic waveforms. Accuracy is validated against the 1-D and 3-D solutions of published studies. The source term and convolution approaches are compared. Synthetic examples show that the latter approach simplifies the waveform incorporation in TEM modelling and substantially improves time-stepping efficiency without sacrificing accuracy.
1 January 2025 in IEEE Access
15 January 2026 in IEEE Sensors Journal
This study addresses the high-frequency limitations of conventional single-resonance models for induction magnetometers (IMs) with magnetic flux negative feedback. At frequencies beyond the first resonance, parasitic capacitive effects become dominant, necessitating a more physically complete model. We therefore develop a dual-resonance equivalent circuit that incorporates a second resonance point to accurately characterize this high-frequency behavior. The stability of this extended model is rigorously investigated using the Routh-Hurwitz criterion, establishing critical stability conditions for the feedback system. Experimental validation via frequency-response testing confirms the model’s superior accuracy in predicting sensor response across a wide bandwidth. The research ultimately delivers a verified dual-resonance model and practical stability criteria, providing foundational insights for IM circuit design and enabling the development of high-stability, high-precision sensors for advanced applications.