Chong Zhang

Chong Zhang

Auto-generated profile, based on publicly available information

Chong Zhang

Department of Biomedical Engineering, College of Future Technology, Peking University, Beijing, China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 June 2022 in Science Advances
Verified
Journal Article
Open access
Yue DongYue Dong
Yue Dong
LWLu Wang
Lu Wang
NXNeng Xia
Neng Xia
ZYZhengxin Yang
Zhengxin Yang
CZChong Zhang
Chong Zhang
Li ZhangLi Zhang
Li Zhang
Intelligent magnetic soft robots capable of programmable structural changes and multifunctionality modalities depend on material architectures and methods for controlling magnetization profiles. While some efforts have been made, there are still key challenges in achieving programmable magnetization profile and creating heterogeneous architectures. Here, we directly embed programmed magnetization patterns (magnetization modules) into the adhesive sticker layers to construct soft robots with programmable magnetization profiles and geometries and then integrate spatially distributed functional modules. Functional modules including temperature and ultraviolet light sensing particles, pH sensing sheets, oil sensing foams, positioning electronic component, circuit foils, and therapy patch films are integrated into soft robots. These test beds are used to explore multimodal robot locomotion and various applications related to environmental sensing and detection, circuit repairing, and gastric ulcer coating, respectively. This proposed approach to engineering modular soft material systems has the potential to expand the functionality, versatility, and adaptability of soft robots.

10 March 2023 in Science Advances
Verified
Journal Article
Closed access
CZChong Zhang
Chong Zhang
CPChengfeng Pan
Chengfeng Pan
KCKai Fung Chan
Kai Fung Chan
JGJinyang Gao
Jinyang Gao
ZYZhengxin Yang
Zhengxin Yang
Li ZhangLi Zhang
Li Zhang
Electrical stimulation is a promising method to modulate gastrointestinal disorders. However, conventional stimulators need invasive implantation and removal surgeries associated with risks of infection and secondary injuries. Here, we report a battery-free and deformable electronic esophageal stent for wireless stimulation of the lower esophageal sphincter in a noninvasive fashion. The stent consists of an elastic receiver antenna infilled with liquid metal (eutectic gallium-indium), a superelastic nitinol stent skeleton, and a stretchable pulse generator that jointly enables 150% axial elongation and 50% radial compression for transoral delivery through the narrow esophagus. The compliant stent adaptive to the dynamic environment of the esophagus can wirelessly harvest energy through deep tissue. Continuous electrical stimulations delivered by the stent in vivo using pig models significantly increase the pressure of the lower esophageal sphincter. The electronic stent provides a noninvasive platform for bioelectronic therapies in the gastrointestinal tract without the need for open surgery.

23 July 2024 in Nature Materials
Verified
Journal Article
Closed access
PDF file
XWXin Wang
Xin Wang
CPChengfeng Pan
Chengfeng Pan
NXNeng Xia
Neng Xia
CZChong Zhang
Chong Zhang
BHBo Hao
Bo Hao
Li ZhangLi Zhang
Li Zhang

4 November 2021 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
ZYZhengxin Yang
Zhengxin Yang
Lidong YangLidong Yang
Lidong Yang
MZMoqiu Zhang
Moqiu Zhang
CZChong Zhang
Chong Zhang
SYSimon Chun Ho Yu
Simon Chun Ho Yu
Li ZhangLi Zhang
Li Zhang
The endovascular intervention has been widely used to treat occlusive peripheral vascular disease (PVD). However, the current procedure has concerns such as low successful rate, undesired trauma, and radiation exposure. This article proposes a robotic solution to mitigate these limitations. A miniature magnetic driller-tipped guidewire (MDG) is designed, which performs 1) controllable bending under directional magnetic fields to navigate in complex vasculature and 2) mechanical drilling under rotating magnetic fields to pass through clogged regions. An integrated actuation system is adopted for magnetic control and ultrasound (US) imaging in a large workspace. A control framework composed of the preoperative and intraoperative stages is developed, which internally coordinates all system modules, addresses noisy US imaging, and provides convenient operation. Demonstrations under an optical camera verify the flexible steering ability and effective unclogging motion of the MDG. Furthermore, US image-monitored in vitro experiments validate the overall hardware platform and control strategy. The designed MDG realizes dual objectives, including controllability at bifurcations and penetrability at clots. The introduced US imaging modality largely reduces radiation hazards in conventional catheterization. This article studies the intervention of the MDG under electromagnetic field navigation and US imaging guidance. The proposed workflow has the potential to improve operational safety and clinical outcomes of the occlusive PVD treatment.

23 January 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
MZMoqiu Zhang
Moqiu Zhang
Lidong YangLidong Yang
Lidong Yang
CZChong Zhang
Chong Zhang
ZYZhengxin Yang
Zhengxin Yang
Li ZhangLi Zhang
Li Zhang
Simultaneous magnetic localization and actuation in a human-scale workspace are challenging but essential for medical applications such as whole gastrointestinal (GI) tract monitoring and blood clot clearance in the leg. In this paper, we propose a five-dimensional (5-D) magnetic localization and actuation system that can track and actuate magnetic robots in a cylindrical workspace with a diameter of 500 mm. Based on the eye-in-hand configuration of the sensor array and the flexibility of the mobile electromagnetic manipulation system (mEMS), we realize a high localization accuracy in a large workspace with only twenty-five sensors. Moreover, we design an accurate magnetic field modeling method that can attenuate the electromagnets’ hysteresis and provide a precise actuation field estimation. Taking advantage of the mobile sensor array, we developed a signal-quality-based tracking strategy (STS) that could improve the localization performance by adjusting the movement of the sensor array. The effectiveness and advantages of the proposed methods are verified by simulations and experiments. Results show that the signal-quality-based tracking strategy could decrease 25% position root-mean-square error (RMSE). The resulting position RMSE and orientation RMSE are 2.02 mm and 8.24° respectively. We experimentally prove the viability of the proposed strategy by propelling a magnetic helical robot through a 400 mm long three-dimensional (3-D) twisted silicone phantom.

27 September 2021
Verified
Conference Paper
Closed access
MZMoqiu Zhang
Moqiu Zhang
Lidong YangLidong Yang
Lidong Yang
CZChong Zhang
Chong Zhang
ZYZhengxin Yang
Zhengxin Yang
Li ZhangLi Zhang
Li Zhang
Large workspace localization of magnetic robots is important for medical applications. This paper presents a novel localization strategy to achieve simultaneous localization and actuation of magnetic robots using hall-effect sensors. We integrate 25 sensors into a sensing probe and mount it on to the mobile-coil system, which realizes accurate sensing and actuation of magnetic devices within a cylindrical workspace of ϕ500 mm×150 mm. Simulation results show the average localization error using the proposed method is 1.7 mm. A verification experiment is conducted to prove the design advantages; Another two experiments are conducted to demonstrate the simultaneous actuation and localization of a torque-driven robot and a force-driven floating robot respectively. For the force-driven floating robot, the average variation between the localization results and the desired trajectory is less than 2 mm.