Bengt Norén

Bengt Norén

Auto-generated profile, based on publicly available information

Bengt Norén

Department of Radiology, and Department of Medical and Health Sciences, Linköping University

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 July 2020 in Scandinavian Journal of Gastroenterology
Verified
Journal Article
Open access
MFMikael F. Forsgren
Mikael F. Forsgren
PNPatrik Nasr
Patrik Nasr
MKMarkus Karlsson
Markus Karlsson
NDNils Dahlström
Nils Dahlström
BNBengt Norén
Bengt Norén
PLPeter Lundberg
Peter Lundberg
Accurate biomarkers for quantifying liver fibrosis are important for clinical practice and trial end-points. We compared the diagnostic performance of magnetic resonance imaging (MRI), including ga...

1 January 2015 in European Journal of Radiology Open
Verified
Journal Article
Open access
MFMikael F. Forsgren
Mikael F. Forsgren
BNBengt Norén
Bengt Norén
JKJohan Kihlberg
Johan Kihlberg
OLOlof Dahlqvist Leinhard
Olof Dahlqvist Leinhard
SKStergios Kechagias
Stergios Kechagias
PLPeter Lundberg
Peter Lundberg
Continuous monitoring of liver fibrosis progression in patients is not feasible with the current diagnostic golden standard (needle biopsy). Recently, magnetic resonance elastography (MRE) has emerged as a promising method for such continuous monitoring. Since there are different MRE methods that could be used in a clinical setting there is a need to investigate whether measurements produced by these MRE methods are comparable. Hence, the purpose of this pilot study was to evaluate whether the measurements of the viscoelastic properties produced by 2D (stiffness) and 3D (elasticity and 'G abs,Elastic') MRE are comparable. Seven patients with diffuse or suspect diffuse liver disease were examined in the same day with the two MRE methods. 2D MRE was performed using an acoustic passive transducer, with a 1.5 T GE 450 W MR system. 3D MRE was performed using an electromagnetic active transducer, with a 1.5 T Philips Achieva MR system. Finally, mean viscoelastic values were extracted from the same anatomical region for both methods by an experienced radiologist. Stiffness correlated well with the elasticity, R (2) = 0.96 (P < 0.001; slope = 1.08, intercept = 0.61 kPa), as well as with 'G abs,Elastic' R (2) = 0.96 (P < 0.001; slope = 0.95, intercept = 0.28 kPa). This pilot study shows that different MRE methods can produce comparable measurements of the viscoelastic properties of the liver. The existence of such comparable measurements is important, both from a clinical as well as a research perspective, since it allows for equipment-independent monitoring of disease progression.

13 February 2024 in medRxiv
Verified
Preprint
Open access
PDF file
CSChristian Simonsson
Christian Simonsson
WBWolf Claus Bartholomä
Wolf Claus Bartholomä
ALAnna Lindhoff Larsson
Anna Lindhoff Larsson
MKMarkus Karlsson
Markus Karlsson
SCShan Cai
Shan Cai
PLPeter Lundberg
Peter Lundberg
Background & Aims: For a range of liver malignancies, the only curative treatment option may be hepatectomy, which may have fatal complications. Therefore, an unbiased pre-operative risk assessment is vital, however, at present the assessment is typically based on global liver function only. Magnetic resonance imaging (MRI) modalities have the possibility to aid this assessment, by introducing additional characterization of liver parenchymal, such as non-invasive quantification of steatosis, fibrosis, and uptake function, both for global and regional assessment. To this cause, we here present a prospective observation study (LIFE), in which patients underwent extensive MR-examinations both before and after resective-surgery. Approach and Results: A total of 13 patients undergoing hepatectomy underwent a pre- (n=13) and post (m=5) multimodal MRI examination (within 3-5 days of the surgery) (Fig. 1B). The multimodal MR-examination included DCE, 3D-MRE, fat fraction measurements (PDFF by MRS, 6PD). Using these measurements, we also construct individual patient profiles by including conventional functional, and volumetric measurements, into a multi-parametric space. As a proof of concept, the areas of each profile, denoted ‘multiparametric profile area’ (MPA, and aMPA) were calculated, to create a measurement comprising information from all modalities. At a group-level, no clear pattern emerged of MPA or aMPA between groups with different extent of resection. In contrast, on a case-by-case basis, several parameters contributed to high individual MPA or aMPA-values, suggesting tissue abnormalities. With respect to regional DCE measurements, i.e ., relative enhancement at 20 minutes, a clear variation between function in segments, within and between the individuals, was observed. Conclusions: In this combined pre- and post-observational case-based study ranging from very extensive (i) liver surgery to minor (ii), or none (iii), we aimed to describe how a multi-modal MRI examination before hepatectomy could yield valuable information for the pre-operative assessment, with a particular focus on a Couinaud-segmental level. The use of a multi-modal approach allows for a broad spectral characterization of several aspects of the remnant tissue. However, the effectiveness and clinical benefit of each parameter, and how to further optimize an abbreviated clinical MR-protocol needs to be confirmed.