Objectives: The purpose of this study was to develop a procedure to investigate the occurrence, character and causes of magnetic resonance (MR) imaging incidents. Methods: A semi-structured questionnaire was developed containing details such as safety zones, examination complexity, staff MR knowledge, staff categories, and implementation of EU directive 2013/35. We focused on formally reported incidents that had occurred during 2014–2019, and unreported incidents during one year. Thirteen clinical MR units were visited, and the managing radiographer was interviewed. Open questions were analysed using conventionally adopted content analysis. Results: Thirty-seven written reports for 5 years and an additional 12 oral reports for 1 year were analysed. Only 38% of the incidents were reported formally. Some of these incidents were catastrophic. Negative correlations were observed between the number of annual incidents (per scanner) and staff MR knowledge (Spearman’s rho − 0.41, p < 0.05) as well as the number of MR physicists per scanner (− 0.48, p < 0.05). It was notable that only half of the sites had implemented the EU directive. Quotes like ‘Burns are to be expected in MR’ and not even knowing the name of the incident reporting system suggested an inadequate safety culture. Finally, there was a desire among staff for MR safety education. Conclusions: MR-related incidents were greatly underreported, and some incidents could have had catastrophic outcomes. There is a great desire among radiographers to enhance the safety culture, but to achieve this, much more accessible education is required, as well as focused involvement of the management of the operations. Key Points: • Only one in three magnetic resonance–related incidents were reported.• Several magnetic resonance incidents could have led to catastrophic consequences.• Much increased knowledge about magnetic resonance safety is needed by radiologists and radiographers.
1 January 2015 in European Journal of Radiology Open
Continuous monitoring of liver fibrosis progression in patients is not feasible with the current diagnostic golden standard (needle biopsy). Recently, magnetic resonance elastography (MRE) has emerged as a promising method for such continuous monitoring. Since there are different MRE methods that could be used in a clinical setting there is a need to investigate whether measurements produced by these MRE methods are comparable. Hence, the purpose of this pilot study was to evaluate whether the measurements of the viscoelastic properties produced by 2D (stiffness) and 3D (elasticity and 'G abs,Elastic') MRE are comparable. Seven patients with diffuse or suspect diffuse liver disease were examined in the same day with the two MRE methods. 2D MRE was performed using an acoustic passive transducer, with a 1.5 T GE 450 W MR system. 3D MRE was performed using an electromagnetic active transducer, with a 1.5 T Philips Achieva MR system. Finally, mean viscoelastic values were extracted from the same anatomical region for both methods by an experienced radiologist. Stiffness correlated well with the elasticity, R (2) = 0.96 (P < 0.001; slope = 1.08, intercept = 0.61 kPa), as well as with 'G abs,Elastic' R (2) = 0.96 (P < 0.001; slope = 0.95, intercept = 0.28 kPa). This pilot study shows that different MRE methods can produce comparable measurements of the viscoelastic properties of the liver. The existence of such comparable measurements is important, both from a clinical as well as a research perspective, since it allows for equipment-independent monitoring of disease progression.
1 January 2020 in Journal of Cardiovascular Magnetic Resonance
Several cardiovascular magnetic resonance (CMR) techniques can measure myocardial strain and torsion with high accuracy. The purpose of this study was to compare displacement encoding with stimulated echoes (DENSE), tagging and feature tracking (FT) for measuring circumferential and radial myocardial strain and myocardial torsion in order to assess myocardial function and infarct scar burden both at a global and at a segmental level. 116 patients with a high likelihood of coronary artery disease (European SCORE > 15%) underwent CMR examination including cine images, tagging, DENSE and late gadolinium enhancement (LGE) in the short axis direction. In total, 97 patients had signs of myocardial disease and 19 had no abnormalities in terms of left ventricular (LV) wall mass index, LV ejection fraction, wall motion, LGE or a history of myocardial infarction. Thirty-four patients had myocardial infarct scar with a transmural LGE extent (transmurality) that exceeded 50% of the wall thickness in at least one segment. Global circumferential strain (GCS) and global radial strain (GRS) was analyzed using FT of cine loops, deformation of tag lines or DENSE displacement. DENSE and tagging both showed high sensitivity (82% and 71%) at a specificity of 80% for the detection of segments with > 50% LGE transmurality, and receiver operating characteristics (ROC) analysis showed significantly higher area under the curve-values (AUC) for DENSE (0.87) than for tagging (0.83, p < 0.001) and FT (0.66, p = 0.003). GCS correlated with global LGE when determined with DENSE (r = 0.41), tagging (r = 0.37) and FT (r = 0.15). GRS had a low but significant negative correlation with LGE; DENSE r = − 0.10, FT r = − 0.07 and tagging r = − 0.16. Torsion from DENSE and tagging had a weak correlation (− 0.20 and − 0.22 respectively) with global LGE. Circumferential strain from DENSE detected segments with > 50% scar with a higher AUC than strain determined from tagging and FT at a segmental level. GCS and torsion computed from DENSE and tagging showed similar correlation with global scar size, while when computed from FT, the correlation was lower.
Objectives: To evaluate the diagnostic performance of ultrasound guided attenuation parameter (UGAP) for evaluating liver fat content with different probe forces and body positions, in relation to sex, and compared with proton density fat fraction (PDFF). Methods: We prospectively enrolled a metabolic dysfunction-associated steatotic liver disease (MASLD) cohort that underwent UGAP and PDFF in the autumn of 2022. Mean UGAP values were obtained in supine and 30° left decubitus body position with normal 4 N and increased 30 N probe force. The diagnostic performance was evaluated by the area under the receiver operating characteristic curve (AUC). Results: Among 60 individuals (mean age 52.9 years, SD 12.9; 30 men), we found the best diagnostic performance with increased probe force in 30° left decubitus position (AUC 0.90; 95% CI 0.82–0.98) with a cut-off of 0.58 dB/cm/MHz. For men, the best performance was in supine (AUC 0.91; 95% CI 0.81–1.00) with a cut-off of 0.60 dB/cm/MHz, and for women, 30° left decubitus position (AUC 0.93; 95% CI 0.83–1.00), with a cut-off 0.56 dB/cm/MHz, and increased 30 N probe force for both genders. No difference was in the mean UGAP value when altering body position. UGAP showed good to excellent intra-reproducibility (Intra-class correlation 0.872; 95% CI 0.794–0.921). Conclusion: UGAP provides excellent diagnostic performance to detect liver fat content in metabolic dysfunction-associated steatotic liver diseases, with good to excellent intra-reproducibility. Regardless of sex, the highest diagnostic accuracy is achieved with increased probe force with men in supine and women in 30° left decubitus position, yielding different cut-offs. Clinical relevance statement: The ultrasound method ultrasound-guided attenuation parameter shows excellent diagnostic accuracy and performs with good to excellent reproducibility. There is a possibility to alter body position and increase probe pressure, and different performances for men and women should be considered for the highest accuracy. Key Points: • There is a possibility to alter body position when performing the ultrasound method ultrasound-guided attenuation parameter.• Increase probe pressure for the highest accuracy.• Different performances for men and women should be considered. Graphical
Adverse reactions to iodinated contrast media, which is used during computed tomography (CT) examinations, are rare. As a result, radiographers have limited experience handling those situations and may feel uncertainty and a lack of confidence. The aim of this study was to investigate radiographers' confidence in handling hypersensitivity reactions to contrast media during CT examinations. A survey in the form of a questionnaire was conducted to gather both quantitative and qualitative data. There were 31 clinics that participated in this study, of which four were university hospitals, 17 were medium-sized hospitals and 10 were small hospitals. In total, the questionnaires were distributed to 700 radiographers. The questionnaire contained 12 questions and was distributed via email with a link to the questionnaire. Two hundred-ninety radiographers participated in the survey. 72% of the respondents answered in the middle of the four-point scale (2-3) in response to the statement "I feel confident in handling hypersensitivity reactions". 65% answered that they did not have routines for training regularly regarding hypersensitivity reactions. Qualitative data showed that many of the respondents wished to receive education and training regularly. The confidence of radiographers regarding the management of hypersensitivity reactions was deficient and most of the respondents wished they felt more confident. To increase radiographers' confidence in handling hypersensitivity reactions, it is recommended that the radiology clinics review their routines and the possibility to implement regular training.
Artificial intelligence (AI) is increasingly integrated into radiology workflows, supporting tasks such as image reconstruction, patient positioning, and administrative processes. While these developments promise efficiency and improved diagnostic quality, their impact on radiographers' professional roles remains unclear, particularly in Sweden, where formal AI training is absent, and staffing shortages persist. Understanding radiographers' perspectives is essential for safe implementation and workforce sustainability. This study aims to explore how the professional role of radiographers is influenced by the current and future implementation of AI in radiology. A qualitative multi-case study was conducted across three Swedish university hospitals. Semi-structured interviews were carried out with 18 strategically selected participants, including section leaders, researchers, and department managers. Data were analysed using thematic analysis, focusing on perceptions of AI, its impact on professional identity, and anticipated future tasks. Five themes emerged in each of the 18 cases and were compared across hospitals. Participants reported a lack of training and uncertainty about the future, as radiographers' roles are rarely considered in technology implementation. Maintaining competence and professional development was highlighted as critical when introducing AI. AI is present in workflows such as image reconstruction, protocol optimisation and patient positioning, but formal training remains limited. Participants viewed AI as both a facilitator of daily work and a potential threat to core tasks, raising concerns about deskilling and loss of identity. Maintaining responsibility for patient safety was emphasised. Thoughtful implementation, structured training, and inclusive planning could enable radiographers to assume advanced roles, including oversight of AI outputs. Including radiographers in the implementation of AI models and formalising AI education, both in undergraduate education and postgraduate courses, are essential for strengthening the profession.