Kyubo Shin

Kyubo Shin

Auto-generated profile, based on publicly available information

Kyubo Shin

Thyroscope inc, Ulsan, Republic of Korea

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 April 2025 in Ophthalmology Science
Verified
Journal Article
Open access
JPJoonhyeon Park
Joonhyeon Park
JYJin Sook Yoon
Jin Sook Yoon
NKNamju Kim
Namju Kim
KSKyubo Shin
Kyubo Shin
HPHyun Young Park
Hyun Young Park
JKJaeSang Ko
JaeSang Ko
To develop and evaluate a deep learning (DL)-assisted system for proptosis measurement using facial photographs in thyroid eye disease (TED). A retrospective cohort study. This study included 1108 patients with TED from Severance Hospital (SH) and 171 from Seoul National University Bundang Hospital (SNUBH). The DL-assisted system was trained using 1610 facial images paired with Hertel exophthalmometry measurements from SH and externally validated using 511 SNUBH images. The system employs a dual-stream ResNet-18 neural network, utilizing both red-green-blue images and depth maps generated by the ZoeDepth algorithm. Accuracy was assessed using mean absolute error (MAE), Pearson correlation coefficient, intraclass correlation coefficient (ICC), and area under the curve of the receiver operating characteristic curve. The DL-assisted system achieved an MAE of 1.27 mm for the SH dataset and 1.24 mm for the SNUBH dataset. Pearson correlation coefficients were 0.82 and 0.77, respectively, with ICCs indicating strong reliability (0.80 for SH and 0.73 for SNUBH). The receiver operating characteristic curve analysis showed area under the curves of 0.91 for SH and 0.88 for SNUBH in detecting proptosis. The system detected significant proptosis changes (≥ 2 mm) with 74.6% accuracy. The DL-assisted system offers an accurate, accessible method for exophthalmometry in patients with TED using facial photographs. This tool presents a promising alternative to traditional exophthalmometry, potentially improving access to reliable proptosis measurement in both clinical and nonspecialist settings. Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

13 January 2020 in IEEE Access
Verified
Journal Article
Open access
SCSeokwoo Choi
Seokwoo Choi
KSKyubo Shin
Kyubo Shin
HKHyoil Kim
Hyoil Kim
Low latency networking is gaining attention to support futuristic network applications like the Tactile Internet with stringent end-to-end latency requirements. In realizing the vision, cut-through (CT) switching is believed to be a promising solution to significantly reduce the latency of today's store-and-forward switching, by splitting a packet into smaller chunks called flits and forwarding them concurrently through input and output ports of a switch. Nevertheless, the end-to-end latency performance of CT switching has not been well studied in heterogeneous networks, which hinders its adoption to general-topology networks with heterogeneous links. To fill the gap, this paper proposes an end-to-end latency prediction model in a heterogeneous CT switching network, where the major challenge comes from the fact that a packet's end-to-end latency relies on how and when its flits are forwarded at each switch while each flit is forwarded individually. As a result, traditional packet-based queueing models are not instantly applicable, and thus we construct a method to estimate per-hop queueing delay via M/G/c queueing approximation, based on which we predict end-to-end latency of a packet. Our extensive simulation results show that the proposed model achieves 3.98-6.05% 90th-percentile error in end-to-end latency prediction.

25 May 2018 in Journal of the Korean Society for Marine Environment & Energy
Verified
Journal Article
Closed access
GCGun Hwan Choi
Gun Hwan Choi
RJRho-Taek Jung
Rho-Taek Jung
BLByung Ho Lee
Byung Ho Lee
KSKyubo Shin
Kyubo Shin

10 March 2025 in Computers & Industrial Engineering
Verified
Journal Article
Closed access
YOYongKyung Oh
YongKyung Oh
GKGiheon Koh
Giheon Koh
JKJiin Kwak
Jiin Kwak
KSKyubo Shin
Kyubo Shin
GKGi-Soo Kim
Gi-Soo Kim
SKSungil Kim
Sungil Kim

15 September 2026 in British Journal of Ophthalmology
Verified
Journal Article
Closed access
PDF file
JPJoon Hyeon Park
Joon Hyeon Park
HBHyeong Ju Byeon
Hyeong Ju Byeon
KSKyubo Shin
Kyubo Shin
HJHyunJo Jang
HyunJo Jang
JKJongchan Kim
Jongchan Kim
JKJaeSang Ko
JaeSang Ko
Aims: To evaluate agreement between photo-based automated exophthalmometry and manual Hertel exophthalmometry in healthy individuals and patients with non-thyroidal orbital disease, with a deep learning system trained exclusively in thyroid eye disease (TED) cohorts applied without retraining or fine-tuning. Methods: This was a retrospective observational study. A total of 269 individuals were included in the study, including 95 healthy controls and 174 patients with unilateral non-TED orbital pathology. Automated measurements obtained using Glandy EXO from same-day frontal facial photographs were compared with corresponding manual Hertel exophthalmometry measurements. Agreement was assessed using Pearson correlation coefficient (PCC), mean absolute error (MAE), intraclass correlation coefficient (ICC) and Bland-Altman analysis. Diagnostic performance for clinically significant intereye asymmetry (>2.0 mm) was also evaluated. Results: The system showed good agreement with Hertel exophthalmometry in the eyes of healthy controls (PCC 0.80; MAE 0.86 mm; ICC 0.80) as well as the affected (PCC 0.81; MAE 1.41 mm; ICC 0.75) and fellow (PCC 0.76; MAE 1.03 mm; ICC 0.75) eyes of patients. Overall, 84.8% of measurements were within 2.0 mm of the manual Hertel values. The sensitivity, specificity and accuracy of the system for detecting clinically significant intereye asymmetry were 59.6%, 95.0% and 83.3%, respectively. Conclusions: The TED-trained photoexophthalmometry system showed good agreement with Hertel measurements in healthy individuals and patients with non-TED orbital disease. These findings support its use as an adjunct to clinical examination for objective quantification and documentation of globe position.

24 May 2018 in Computer Networks
Verified
Journal Article
Closed access
KSKyubo Shin
Kyubo Shin
HKHyoil Kim
Hyoil Kim
SCSe Young Chun
Se Young Chun
DSDonghoon Shin
Donghoon Shin