Yue Yin

Yue Yin

Auto-generated profile, based on publicly available information

Yue Yin

Tsinghua Beijing Innovation Center for Future Chips, School of Integrated Circuits, Tsinghua University, Beijing, China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 July 2021 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
YYYue Yin
Yue Yin
SASyed Muhammad Abubakar
Syed Muhammad Abubakar
STSongyao Tan
Songyao Tan
JSJiahua Shi
Jiahua Shi
PYPeilin Yang
Peilin Yang
SUSeng-Pan U
Seng-Pan U
An ultra-low power ECG processor ASIC (application specific integrated circuit) with R-wave detection and data compression is presented, which is designed for the long-term implantable cardiac monitoring (ICM) device for arrhythmia diagnosis. An adaptive derivative-based detection algorithm with low computation overhead for potential arrhythmia recording is proposed to detect arrhythmia with the occasional abnormal heart beats. In order to save as much as possible cardiac information with the limited memory size available in the ICM device, a hierarchical data buffer structure is proposed which saves 3 types of data, including the raw ECG data segments of 2 seconds, compressed ECG data segments of 45 seconds, and R-peak values and interval lengths of >2000 beat cycles. A modified swinging-door-trending (SDT) method is proposed for the ECG data compression. The ASIC has been implemented based on fully-customized near-threshold standard cells using the thick-gate transistors in 65-nm CMOS technology for low dynamic power consumption and leakage. The ASIC core occupies a die area of 1.77 mm 2 . The measured total power is 2.63 μW, which is among the ECG processors with the lowest core power consumption. It exhibits a relatively high positive precision rate ( P + ) of 99.3% with a sensitivity of 98.2%, in contrast to the similar designs in literature with the same core power consumption level. Also, an ECG data compression ratio ( CR ) of up to 17.0 has been achieved, with a good trade-off between the compression efficiency and loss.

27 May 2021 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
WYWendi Yang
Wendi Yang
HJHanjun Jiang
Hanjun Jiang
YYYue Yin
Yue Yin
ZWZhihua Wang
Zhihua Wang
An ultra-low-power low-noise analog front end (AFE) is presented in this work, aiming for long-term ECG with clear P-waves for clinical diagnose. The chopper amplifier with passive noise filter and PWM based offset cancellation results in an input-reference noise of 0.39 μVrms, which shows 3.7X noise improvements among the state-of-the-art designs. With the digital offset cancellation by the pulse-width modulation wave, the AFE achieves a low input-referred dc offset of 0.4 μV among 9 tested chips and a low drift under 30 μV. A dynamic scale ADC with low-power comparator strategy prevents the instability and signal-loss, achieving an SFDR of 71.6 dB. The proposed AFE achieves a noise-efficient-factor (NEF) of 2.4 with a power consumption of 4 μW. The fabricated chip is demonstrated in a miniature prototype for long-term ECG monitoring application, presenting a clear ECG waveform with visible P-wave. The simultaneously ECG recording with a medical grade 12-lead ECG Holter shows the effective acquisition of the prototype, proofing the better noise performance.