Zhejun Xu

Zhejun Xu

Auto-generated profile, based on publicly available information

Zhejun Xu

The University of Sydney

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 May 2024 in Advanced Sensor Research
Verified
Journal Article
Open access
ZXZhejun Xu
Zhejun Xu
AJArun Jaiswal
Arun Jaiswal
XLXiaochen Liu
Xiaochen Liu
ZYZhenxu Yang
Zhenxu Yang
QYQiankun Yin
Qiankun Yin
KYKen-Tye Yong
Ken-Tye Yong
This review delves into the significant advancements in microfluidic technology since 2017, highlighting its critical role in shrinking device sizes and integrating advanced surface functionalization techniques. It showcases how microfluidics, an interdisciplinary field, has revolutionized fluid manipulation on a microscale, enabling the creation of cost‐effective, portable devices for on‐the‐spot analyses, like heavy metal ion detection. From its early days rooted in ancient observations to cutting‐edge uses of materials like silicon, glass, polydimethylsiloxane (PDMS), and paper, this review charts microfluidics’ dynamic evolution. It emphasizes the transformative impact of surface functionalization methods, including silanization and plasma treatments, in enhancing device materials' performance. Moreover, this review anticipates the exciting convergence of microfluidics with emerging technologies like droplet microfluidics and three‐dimensional (3D) printing, alongside nanotechnology, forecasting a future of sophisticated analytical tools, point‐of‐care diagnostics, and improved detection systems. It acknowledges the hurdles in scaling production and achieving universal reliability and standardization. This review highlights the transformative impact of microfluidic technology on diagnostics and environmental surveillance, emphasizing its utility in deploying compact sensors for comprehensive and concurrent evaluations of water quality.

7 June 2024 in Particle & Particle Systems Characterization
Verified
Journal Article
Open access
ZYZhenxu Yang
Zhenxu Yang
QYQiankun Yin
Qiankun Yin
MHMengfan He
Mengfan He
SCShin‐Wei Chong
Shin‐Wei Chong
ZXZhejun Xu
Zhejun Xu
KYKen-Tye Yong
Ken-Tye Yong
Microfluidic‐assisted synthesis of nanoparticles has generated significant interest for its precise control and high throughput capabilities. Among various nanomaterials, gold nanoparticles (AuNPs) have shown remarkable potential in numerous applications, such as disease detection, photothermotherapy, drug delivery, and even defense applications. Recent synthesis strategy of peptide‐mediated method has sparked greater interest by offering unique chiroptical properties and their applications in biomedical applications. In this study, the use of droplet microfluidics is explored for the synthesis of peptide‐mediated AuNPs, aiming to accelerate automated production via flow chemistry. This method leads to the formation of anisotropic gold particles, with sizes ranging from hundreds of nanometers to the micron scale. The interfacial energy is identified at the water/oil interface as a critical factor influencing this outcome, with L‐glutathione (L‐GSH) playing a significant role in the development of hyper‐branched structures. These results demonstrate the capability of droplet microfluidics in producing anisotropic gold particles at micron scales, presenting new possibilities for the advancement of nanoparticle synthesis techniques.

18 June 2026 in Journal of Physics: Photonics
Verified
Journal Article
Open access
ZXZhejun Xu
Zhejun Xu
AJArun Jaiswal
Arun Jaiswal
QYQiankun Yin
Qiankun Yin
XLXiaochen Liu
Xiaochen Liu
ZYZhenxu Yang
Zhenxu Yang
KYKen-Tye Yong
Ken-Tye Yong
Heavy metal ion contamination is a critical concern for both environmental sustainability and human health. Reliable and sensitive detection methods are essential for effective monitoring and ensuring the safety of drinking water. In recent years, optical fiber sensors have emerged as promising tools due to their high sensitivity, selectivity, and potential for on-site, real-time monitoring. This review explores four primary optical fiber sensing techniques: fluorescencebased sensors, surface plasmon resonance (SPR) sensors, localized surface plasmon resonance (LSPR) sensors, and fiber Bragg grating (FBG) sensors. A comprehensive understanding of these technologies highlights their potential to advance water quality monitoring and guide future sensor development for environmental applications.

15 October 2025 in Nano Select
Verified
Journal Article
Open access
ZXZhejun Xu
Zhejun Xu
AJArun Jaiswal
Arun Jaiswal
XLXiaochen Liu
Xiaochen Liu
ZYZhenxu Yang
Zhenxu Yang
QYQiankun Yin
Qiankun Yin
KYKen-Tye Yong
Ken-Tye Yong
Chelating agents have been extensively used for detecting heavy metal ions in optical fiber sensors. Although various studies have utilized different chelators to enhance the limit of detection, the uniformity of their coverage on the sensor surface is often underexplored. In this study, we used ethylenediaminetetraacetic acid (EDTA), a well‐known zinc chelator, to functionalize the surface of a single‐mode 28 optical fiber (SMF‐28). We then investigated the effect of EDTA coverage density on zinc ion detection. Experimental results revealed non‐uniform EDTA attachment along the fiber surface, leading to varying amounts of zinc binding in different regions. This uneven distribution significantly impacts the efficiency and sensitivity of optical fiber sensors in zinc ion detection. Our findings highlight the need to consider chelator coverage when designing and calibrating optical sensors for robust heavy metal ion detection.

8 March 2026 in Advanced Intelligent Discovery
Verified
Journal Article
Open access
ZYZhenxu Yang
Zhenxu Yang
QYQiankun Yin
Qiankun Yin
QLQingxin Liu
Qingxin Liu
ZXZhejun Xu
Zhejun Xu
YZYe Zhang
Ye Zhang
KYKen-Tye Yong
Ken-Tye Yong
In this study, we present a biomimetic liver‐on‐a‐chip (LOC) device inspired by the structural organisation of the hepatic acinus and developed through COMSOL Multiphysics simulation. The design incorporates antiparallel perfusion channels and microchannel barriers to mimic nutrient delivery and bile drainage in the liver, while maintaining physiologically relevant low shear stress conditions suitable for hepatocyte culture. A truncated LOC model was first used to explore pressure, shear stress, and concentration distributions, revealing that media perfusion minimally perturbs the cell region while bile flow significantly impacts nutrient diffusion. Full‐scale simulations were then performed, demonstrating key discrepancies with the truncated model due to length‐dependent diffusion effects, emphasising the importance of simulating full geometries in transport‐limited systems. The model was validated experimentally with dye‐based flow studies and HepG2 cell culture under dynamic perfusion. Functional validation confirmed that the LOC supports directional solute gradients and cell growth under controlled shear. This integrated in silico–in vitro approach provides a robust framework for the design of organ‐on‐a‐chip systems, reducing development cycles and improving physiological relevance for drug testing and liver disease modelling.