Alan Nugent

Alan Nugent

Auto-generated profile, based on publicly available information

Alan Nugent

Department of Pediatrics, Northwestern University Feinberg School of Medicine, Chicago, IL 60611, USA

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
SRSurendranath Reddy Veeram Reddy
Surendranath Reddy Veeram Reddy
YAYousef Arar
Yousef Arar
RZRiad Abou Zahr
Riad Abou Zahr
VGVasu Gooty
Vasu Gooty
JHJennifer Hernandez
Jennifer Hernandez
THTarique Hussain
Tarique Hussain
Today’s standard of care, in the congenital heart disease (CHD) population, involves performing cardiac catheterization under x-ray fluoroscopy and cardiac magnetic resonance (CMR) imaging separately. The unique ability of CMR to provide real-time functional imaging in multiple views without ionizing radiation exposure has the potential to be a powerful tool for diagnostic and interventional procedures. Limiting fluoroscopic radiation exposure remains a challenge for pediatric interventional cardiologists. This pilot study’s objective is to establish feasibility of right (RHC) and left heart catheterization (LHC) during invasive CMR (iCMR) procedures at our institution in the CHD population. Furthermore, we aim to improve simultaneous visualization of the catheter balloon tip, MR-conditional guidewire, and cardiac/vessel anatomy during iCMR procedures. Subjects with CHD were enrolled in a pilot study for iCMR procedures at 1.5 T with an MR-conditional guidewire. The CMR area is located adjacent to a standard catheterization laboratory. Using the interactive scanning mode for real-time control of the imaging location, a dilute gadolinium-filled balloon-tip catheter was used in combination with an MR-conditional guidewire to obtain cardiac saturations and hemodynamics. A recently developed catheter tracking technique using a real-time single-shot balanced steady-state free precession (bSSFP), flip angle (FA) 35–45°, echo time (TE) 1.3 ms, repetition time (TR) 2.7 ms, 40° partial saturation (pSAT) pre-pulse was used to visualize the gadolinium-filled balloon, MR-conditional guidewire, and cardiac structures simultaneously. MR-conditional guidewire visualization was enabled due to susceptibility artifact created by distal markers. Pre-clinical phantom testing was performed to determine the optimum imaging FA-pSAT combination. The iCMR procedure was successfully performed to completion in 31/34 (91%) subjects between August 1st, 2017 to December 13th, 2018. Median age and weight were 7.7 years and 25.2 kg (range: 3 months – 33 years and 8 – 80 kg). Twenty-one subjects had single ventricle (SV) anatomy: one subject was referred for pre-Glenn evaluation, 11 were pre-Fontan evaluations and 9 post-Fontan evaluations for protein losing enteropathy (PLE) and/or cyanosis. Thirteen subjects had bi-ventricular (BiV) anatomy, 4 were referred for coarctation of the aorta (CoA) evaluations, 3 underwent vaso-reactivity testing with inhaled nitric oxide, 3 investigated RV volume dimensions, two underwent branch PA stenosis evaluation, and the remaining subject was status post heart transplant. No catheter related complications were encountered. Average time taken for first pass RHC, LHC/aortic pull back, and to cross the Fontan fenestration was 5.2, 3.0, and 6.5 min, respectively. Total success rate to obtain required data points to complete Fick principle calculations for all patients was 331/337 (98%). Subjects were transferred to the x-ray fluoroscopy lab if further intervention was required including Fontan fenestration device closure, balloon angioplasty of pulmonary arteries/conduits, CoA stenting, and/or coiling of aortopulmonary (AP) collaterals. Starting with subject #10, an MR-conditional guidewire was used in all subsequent subjects (15 SV and 10 BiV) with a success rate of 96% (24/25). Real-time CMR-guided RHC (25/25 subjects, 100%), retrograde and prograde LHC/aortic pull back (24/25 subjects, 96%), CoA crossing (3/4 subjects, 75%) and Fontan fenestration test occlusion (2/3 subjects, 67%) were successfully performed in the majority of subjects when an MR-conditional guidewire was utilized. Feasibility for detailed diagnostic RHC, LHC, and Fontan fenestration test occlusion iCMR procedures in SV and BiV pediatric subjects with complex CHD is demonstrated with the aid of an MR-conditional guidewire. A novel real-time pSAT GRE sequence with optimized FA-pSAT angle has facilitated simultaneous visualization of the catheter balloon tip, MR-conditional guidewire, and cardiac/vessel anatomy during iCMR procedures.

1 December 2021 in Circulation: Cardiovascular Interventions
Verified
Journal Article
Closed access
PDF file
SGSrinath T. Gowda
Srinath T. Gowda
LLLarry Latson
Larry Latson
KSKothandam Sivakumar
Kothandam Sivakumar
GHGurumurthy Hiremath
Gurumurthy Hiremath
MCMatthew Crystal
Matthew Crystal
AQAthar Qureshi
Athar Qureshi
Background: Coronary artery fistulas (CAFs) presenting in infancy are rare, and data regarding postclosure sequelae and follow-up are limited. Methods: A retrospective review of all the neonates and infants (<1 year) was conducted from the CAF registry for CAF treatment. The CAF type (proximal or distal), size, treatment method, and follow-up angiography were reviewed to assess outcomes and coronary remodeling. Results: Forty-eight patients were included from 20 centers. Of these, 30 were proximal and 18 had distal CAF; 39 were large, 7 medium, and 2 had small CAF. The median age and weight was 0.16 years (0.01–1) and 4.2 kg (1.7–10.6). Heart failure was noted in 28 of 48 (58%) patients. Transcatheter closure was performed in 24, surgical closure in 18, and 6 were observed medically. Procedural success was 92% and 94 % for transcatheter closure and surgical closure, respectively. Follow-up data were obtained in 34 of 48 (70%) at a median of 2.9 (0.1–18) years. Angiography to assess remodeling was available in 20 of 48 (41%). I. Optimal remodeling (n=10, 7 proximal and 3 distal CAF). II. Suboptimal remodeling (n=7) included (A) symptomatic coronary thrombosis (n=2, distal CAF), (B) asymptomatic coronary thrombosis (n=3, 1 proximal and 2 distal CAF), and (C) partial thrombosis with residual cul-de-sac (n=1, proximal CAF) and vessel irregularity with stenosis (n=1, distal CAF). Finally, (III) persistent coronary artery dilation (n=4). Antiplatelets and anticoagulation were used in 31 and 7 patients post-closure, respectively. Overall, 7 of 10 (70%) with proximal CAF had optimal remodeling, but 5 of 11 (45%) with distal CAF had suboptimal remodeling. Only 1 of 7 patients with suboptimal remodeling were on anticoagulation. Conclusions: Neonates/infants with hemodynamically significant CAF can be treated by transcatheter or surgical closure with excellent procedural success. Patients with distal CAF are at higher risk for suboptimal remodeling. Postclosure anticoagulation and follow-up coronary anatomic evaluation are warranted.

1 May 2021 in Materialia
Verified
Journal Article
Open access
JWJamie Wright
Jamie Wright
ANAnnie Nguyen
Annie Nguyen
NDNandika D'SOuza
Nandika D'SOuza
JFJoseph M. Forbess
Joseph M. Forbess
ANAlan Nugent
Alan Nugent
TWTre Welch
Tre Welch
Intravascular stents for pediatric patients that degrade without inhibiting vessel growth remain a clinical challenge. Here, poly(L-lactide) fibers (DH-BDS) at two thicknesses, 250 μm and 300 μm, were assembled into large, pediatric-sized stents (Ø10 - Ø20 mm). Fibers were characterized mechanically and thermally, then stent mechanical properties were compared to metal controls, while mass loss and degradation kinetics modeling estimated total stent degradation time. Thicker fibers displayed lower stiffness (1969 ± 44 vs 2126 ± 37 MPa) and yield stress (117 ± 12 vs 137 ± 5 MPa) than thinner counterparts, but exhibited similar fail strength (478 ± 28 vs 476 ± 16 MPa) at higher strains (47 ± 2 vs 44 ± 2%). Stents all exhibited crystallinity between 51.3 - 54.4% and fiber glass transition temperatures of 88.6 ± 0.5 °C and 84.6 ± 0.5 °C were well above physiological ranges. Radial strength (0.31 ± 0.01 - 0.34 ± 0.02 N/mm) in thinner stents was similar to metal stents (0.24 - 0.41 N/mm) up to Ø14 mm with no foreshortening and thicker coils granted comparable radial strength (0.32 ± 0.02 - 0.34 ± 0.02 N/mm) in stents larger than Ø14 mm. Both 10 mm (1.17 ± 0.02 % and 0.86 ± 0.1 %) and 12 mm (1.1 ± 0.03% and 0.89 ± 0.1%) stents exhibited minimal weight loss over one year. Degradation kinetics models predicted full stent degradation within 2.8 - 4.5 years depending on thickness. DH-BDS exhibiting hoop strength similar to metal stents and demonstrating minimal degradation and strength loss over the first year before completely disappearing within 3 to 4.5 years show promise as a pediatric interventional alternative to current strategies.

6 March 2018 in Cardiology in the Young
Verified
Journal Article
Closed access
PDF file
LJLorraine James
Lorraine James
ATAnimesh Tandon
Animesh Tandon
ANAlan Nugent
Alan Nugent
SMSadia Malik
Sadia Malik
CRClaudio Ramaciotti
Claudio Ramaciotti
THTarique Hussain
Tarique Hussain
Previous studies have shown that cardiac MRI can be used to evaluate the suitability for infants to undergo the Glenn operation after having undergone the Norwood procedure. We sought to analyse our institutional data retrospectively to identify whether such a policy would be advisable in the current era. We reviewed patients who underwent the Norwood procedure between 1 January, 2006 and 1 January, 2016. All patients undergoing evaluation for the Glenn procedure received clinical evaluation, echocardiography, and cardiac catheterisation. A total of 179 patients were identified; 154 patients (86%) survived to undergo cardiac catheterisation as part of evaluation for the Glenn, and all who were evaluated did not eventually receive the Glenn. Using said algorithm, if cardiac MRI or CT were to be used to rationalise the use of catheterisation, 26 of 154 patients would have required catheterisation after cross-sectional imaging identified vascular obstruction; 83 of 154 patients would have received cross-sectional imaging only; and 45 of 154 would have had catheterisation only. All cases that required intervention, excluding aortopulmonary collaterals, and all cases that were not suitable to progress would have been correctly identified using clinical and echocardiographic criteria in addition to cardiac cross-sectional imaging to rationalise the use of catheterisation. Thus, in cases with acceptable clinical, echocardiographic, and angiographic findings, the additional haemodynamic information from catheterisation is rarely of use for decision-making, and interventions can largely be predicted by angiographic imaging modalities.

19 July 2024 in Pediatric Transplantation
Verified
Journal Article
Closed access
ABArene Butto
Arene Butto
COConor O'HAlloran
Conor O'HAlloran
JKJames Kuo
James Kuo
AJAnna G Joong
Anna G Joong
AHAmanda Hauck
Amanda Hauck
PTPaul Tannous
Paul Tannous

6 March 2019 in World Journal for Pediatric and Congenital Heart Surgery
Verified
Journal Article
Closed access
ESElizabeth H. Stephens
Elizabeth H. Stephens
PTPaul Tannous
Paul Tannous
ANAlan W. Nugent
Alan W. Nugent
AHAmanda L. Hauck
Amanda L. Hauck
JFJoseph M. Forbess
Joseph M. Forbess
Utilization of the Melody valve for mitral valve replacement has been previously reported; however, left ventricular outflow tract obstruction is a frequent concern. In this report, a technique for supra-annular placement of the Melody valve in the mitral position is described which will minimize the risk of left ventricular outflow tract obstruction.