Alessandro Stasolla

Alessandro Stasolla

Auto-generated profile, based on publicly available information

Alessandro Stasolla

Department of Diagnostic, UOC of Diagnostic and Interventional Neuroradiology, San Camillo-Forlanini Hospital, Rome, Italy; 0039-0658704378 (GDR, AS, CP, MF, VC, GL, EL, SF, LB, AP, EP) IEO European Institute of Oncology IRCSS, Milan, Italy (FP) Emergency Department, UOC Of Emergency Radiology San Camillo-Forlanini Hospital, Rome, Italy (MG) Department of Medical Imaging, Azienda Ospedaliero Universitaria (A.O.U.) of Cagliari-Polo di Monserrato, Cagliari, Italy (LS)

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 January 2021 in American Journal of Neuroradiology
Verified
Journal Article
Closed access
PDF file
EPEnrico Pampana
Enrico Pampana
SFS. Fabiano
S. Fabiano
GRG. De Rubeis
G. De Rubeis
LBLuca Bertaccini
Luca Bertaccini
ASA. Stasolla
A. Stasolla
ECE. Cotroneo
E. Cotroneo
BACKGROUND AND PURPOSE: The aspiration technique has gained a prominent role in mechanical thrombectomy. The thrombectomy goal is successful revascularization (modified TICI ≥ 2b) and first-pass effect. The purpose of this study was to evaluate the impact of the vessel-catheter ratio on the modified TICI ≥ 2b and first-pass effect. MATERIALS AND METHODS: This was a retrospective, single-center, cohort study. From January 2018 to April 2020, 111/206 (53.9%) were eligible after applying the exclusion criteria. Culprit vessel diameters were measured by 2 neuroradiologists, and the intraclass correlation coefficient was calculated. The receiver operating characteristic curve was used for assessing the vessel-catheter ratio cutoff for modified TICI ≥ 2b and the first-pass effect. Time to groin puncture and fibrinolysis were weighted using logistic regression. All possible intervals (interval size, 0.1; sliding interval, 0.01) of the vessel-catheter ratio were plotted, and the best and worst intervals were compared using the χ2 test. RESULTS: Modified TICI ≥ 2b outcome was achieved in 75/111 (67.5%), and first-pass effect was achieved in 53/75 (70.6%). The MCA diameter was 2.1 mm with an intraclass correlation coefficient of 0.92. The optimal vessel-catheter ratio cutoffs for modified TICI ≥ 2b were ≤1.51 (accuracy = 0.67; 95% CI, 0.58–0.76; P = 0.001), and for first-pass effect, they were significant (≤1.33; P = .31). The modified TICI ≥ 2b odds ratio and relative risk were 9.2 (95% CI, 2.4–36.2; P = 0.002) and 3.2 (95% CI, 1.2–8.7; P = .024). The odds ratio remained significant after logistic regression (7.4; 95% CI, 1.7–32.5; P = .008). First-pass effect odds ratio and relative risk were not significant (2.1 and 1.5; P > .05, respectively). The modified TICI ≥ 2b best and worst vessel-catheter ratio intervals were not significantly different (55.6% versus 85.7%, P = .12). The first-pass effect best vessel-catheter ratio interval was significantly higher compared with the worst one (78.6% versus 40.0%, P = .03). CONCLUSIONS: The aspiration catheter should be selected according to culprit vessel diameter. The optimal vessel-catheter ratio cutoffs were ≤1.51 for modified TICI ≥ 2b with an odds ratio of 9.2 and a relative risk of 3.2.

27 April 2022 in The Neurohospitalist
Verified
Journal Article
Open access
LPLuca Prosperini
Luca Prosperini
MGMara Gentile
Mara Gentile
MRMonica Ricci
Monica Ricci
CGCarmela Gerace
Carmela Gerace
SFSebastiano Fabiano
Sebastiano Fabiano
ECEnrico Cotroneo
Enrico Cotroneo
A dural arteriovenous fistula (DAVF) is an abnormal direct connection between an intracranial artery and the dural venous sinus. In rare cases, DAVF might show rapidly progressive dementia onset with extrapyramidal signs, often misdiagnosed as Parkinson disease or vascular parkinsonism and, therefore, pharmacological treatments are ineffective. Here, we report the case of 84-year-old man with rapidly progressive parkinsonism and dementia who was initially treated with levodopa without any improvement. Approximately 8 months following the symptom onset, a magnetic resonance (MR) imaging of the brain revealed bilateral and symmetrical hyperintensity of the white matter on both cerebral hemispheres on T2-weighted images. Three-dimensional and post-contrast T1-weighted images showed a subtentorial ovalar area with venous drainage alteration, and hypertrophic left occipital artery direct to venous sac. The angiography study confirmed a diagnosis of DAVF. Endovascular treatment by cook pressure technique successfully provided fistula obliteration. The patient rapidly recovered after the endovascular treatment, with restitutio ad integrum of cognitive functioning and resolution of extrapyramidal syndrome. Approximately 1 year after the endovascular treatment, a brain MR scan with angiogram-MR sequences showed almost complete disappearance of white matter alterations on both cerebral hemispheres, and normal visualization of venous system.

22 August 2025 in American Journal of Neuroradiology
Verified
Journal Article
Closed access
PDF file
GRGianluca De Rubeis
Gianluca De Rubeis
ASAlessandro Stasolla
Alessandro Stasolla
CPChiara Piccioli
Chiara Piccioli
MFMargherita Federici
Margherita Federici
VCValeria Cozzolino
Valeria Cozzolino
EPEnrico Pampana
Enrico Pampana
BACKGROUND AND PURPOSE: According to guideline the computed tomography perfusion (CTP) should read and analysis using computer-aided software. This study evaluates the efficacy of AI/ML (machine learning) -driven software in CTP imaging and the effect of neuroradiologists interpretation of these automated results. MATERIALS AND METHODS: We conducted a retrospective, single-center cohort study from June to December 2023 at a comprehensive stroke center. A total of 132 patients suspected of acute ischemic stroke underwent CTP using. The AI software RAPID.AI was utilized for initial analysis, with subsequent validation and adjustments made by experienced neuroradiologists. The rate of CTP marked as “non reportable”, “reportable” and “reportable with correction” by neuroradiologist was recorded. The degree of confidence in the report of basal and angio-CT scan was assessed before and after CTP visualization. Statistical analysis included logistic regression and F1 score assessments to evaluate the predictive accuracy of AI-generated CTP maps RESULTS: The study found that CTP maps derived from AI software were reportable in 65.2% of cases without artifacts, improved to 87.9% reportable cases when reviewed by neuroradiologists. Key predictive factors for artifact-free CTP maps included motion parameters and the timing of contrast peak distances. There was a significant shift to higher confidence scores of the angiographic phase of the CT after the result of CTP CONCLUSIONS: Neuroradiologists play an indispensable role in enhancing the reliability of CTP imaging by interpreting and correcting AI-processed maps. ABBREVIATIONS: CTP=computed tomography perfusion; AI/ML= Artificial Intelligence/Machine Learning; LVO = Large vessel occlusion