Daria Medvedeva

Daria Medvedeva

Auto-generated profile, based on publicly available information

Daria Medvedeva

HSE University, Moscow, Russian Federation

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 July 2025 in Journal of Neural Engineering
Verified
Journal Article
Closed access
NFNikita Fedosov
Nikita Fedosov
DMDaria Medvedeva
Daria Medvedeva
OSOleg Shevtsov
Oleg Shevtsov
AOAlexei Ossadtchi
Alexei Ossadtchi
Objective. Recent advances in biomagnetic sensing have led to the development of compact, wearable devices capable of detecting weak magnetic fields generated by biological activity. Optically pumped magnetometers (OPMs) have shown significant promise in functional neuroimaging. Brain rhythms play a crucial role in diagnostics, cognitive research, and neurointerfaces. Here we demonstrate that a small number of OPMs can reliably capture sensorimotor rhythms (SMRs). Approach. We conducted movement execution and motor imagery (MI) experiments with nine participants in two distinct magnetically shielded rooms (MSRs), each equipped with different ambient field suppression systems. We used only 4 OPMs located above the sensorimotor region and standard common-spatial-patterns (CSPs) based processing to decode the real and imaginary movement intentions of our participants. We evaluated reproducibility of the CSP components’ spectral profiles and assessed the decoding accuracy deterioration with reduction of OPM’s count. We also assessed the influence of the magnetic field orientation on the decoding accuracy and implemented a real-time MI brain–computer interface (BCI) solution. Main results. Under optimal conditions, OPM sensors deliver informative signals suitable for practical MI BCI applications. Those subjects who participated in the experiments in both MSRs exhibit highly reproducible SMR spectral patterns across two different magnetically shielded environments. The magnetic field components with radial orientation yield higher decoding accuracy than their tangential counterparts. In some subjects we observed more than 80% of binary decoding accuracy using a single OPM sensor. Finally we demonstrate real-time performance of our system along with clearly pronounced and behaviorally relevant fluctuations of the SMR power. Significance. For the first time, we demonstrated reliable and reproducible tracking of SMR components using a small number of contactless OPM sensors during movement execution and MI. Our findings pave the way for more efficient post-stroke neurorehabilitation by enabling MI-based BCI solutions to accelerate functional recovery.

28 March 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
ESEkaterina Skidchenko
Ekaterina Skidchenko
ABAnna Butorina
Anna Butorina
NFNikita Fedosov
Nikita Fedosov
OSOleg Shevtsov
Oleg Shevtsov
DMDaria Medvedeva
Daria Medvedeva
AOAlexei Ossadtchi
Alexei Ossadtchi
This paper addresses several critical aspects of using optically pumped magnetometers (OPMs), focusing on both metrological issues and the enhancement of signal quality. We present a quantitative methodology for OPM measurements standardization and quality evaluation, which is crucial in biomedical applications like magnetoencephalography (MEG). Additionally, we introduce a novel, cost-effective portable active magnetic shielding system - digital adaptive suppression system (DASS) – that represents a significant advancement over traditional analog active shielding. Through comprehensive experimental research, we evaluate first-and third-generation commercial OPMs from QuSpin Inc. in two distinct magnetic environments. Our results demonstrate that the DASS ensures optimal and reliable OPM performance, even in noisy urban settings, surpassing the effectiveness of conventional analog shielding. These findings highlight the need for advanced magnetic shielding solutions to enhance the accuracy and reproducibility of OPM measurements.

16 October 2024
Verified
Book Chapter
Open access
PDF file
VAVladislav Aksiotis
Vladislav Aksiotis
OSOleg Sazonov
Oleg Sazonov
KNKamila Nasrulina
Kamila Nasrulina
DMDaria Medvedeva
Daria Medvedeva
UNUliya Nekrasova
Uliya Nekrasova
AOAlexei Ossadtchi
Alexei Ossadtchi
Individuals with upper limb amputations or congenital defects face substantial challenges in performing daily tasks, often exacerbated by limited functionality in the existing bionic prostheses. To address this, we present an AI-powered virtual reality (VR) system designed to train patients to control bionic prostheses with a high number of degrees of freedom using electromyographic (EMG) activity decoding. Current prosthetic control systems lack sophistication, relying on discrete muscle activity decoding and manual mode switching. Our system employs a novel neural network architecture pre-trained on healthy subjects, facilitating continuous decoding of residual muscle activity to control a virtual limb in the VR. Through three months of training, participants with congenital upper limb dysplasia achieved precise finger-specific control, demonstrating a low error rate and strong correlation between the target and the decoded kinematics. Importantly, the system’s adaptability and its user-friendly interface positively impacted patient experience, offering potential reduction of muscle atrophy risks and psychological benefits while preparing individuals for the use of an advanced prosthetic device. This innovative approach represents a significant step toward enhancing prosthetic functionality and improving the quality of life for upper limb amputees and congenital defect patients.

28 September 2023
Verified
Conference Paper
Closed access
NFNikita Fedosov
Nikita Fedosov
JNJulia Nekrasova
Julia Nekrasova
MMMilana Makarova
Milana Makarova
OSOleg Shevtsov
Oleg Shevtsov
DMDaria Medvedeva
Daria Medvedeva
AOAlexei Ossadtchi
Alexei Ossadtchi
The paper introduces a novel hardware-software complex for the low latency real time phase-dependent transcranial magnetic stimulation (TMS) neurofeedback. The software with key elements implemented on the board of the EEG-recording device accurately tracks the sensorimotor rhythm phase with minimal time-delay and immediately sends the trigger to the TMS-device. An accurate phase estimation is achieved by proper Kalman filter-based state-space modeling of brain rhythm. Our experiments demonstrate the system's viability and its almost instant reaction on the target brain event occurrence. Our results potentially make neurofeedback, cortical mapping, therapeutic TMS-interventions and other applications more reliable and efficient.

20 June 2026
Verified
Conference Paper
Open access
ISIlia Semenkov
Ilia Semenkov
SNSophia Nikiforova
Sophia Nikiforova
NFNikita Fedosov
Nikita Fedosov
OSOleg Sazonov
Oleg Sazonov
DMDaria Medvedeva
Daria Medvedeva
AOAlexei Ossadtchi
Alexei Ossadtchi

28 September 2023
Verified
Conference Paper
Closed access
NFNikita Fedosov
Nikita Fedosov
DMDaria Medvedeva
Daria Medvedeva
OSOleg Shevtsov
Oleg Shevtsov
AOAlexei Ossadtchi
Alexei Ossadtchi
Magnetoencephalography (MEG) is a powerful method for imaging brain activity, with superior spatial resolution compared to electroencephalography (EEG). Superconducting quantum interference device (SQUID)-based systems are mostly used for MEG-acquisition, but they come with limitations like sensor-to-scalp distance and high ownership costs. Optically pumped magnetometers (OPM) sensors are emerging as alternatives, overcoming these issues. We conducted comprehensive research using commercially available OPM sensors QuSpin Gen-2 to explore sensorimotor rhythm within motor-imagery brain-computer interface (BCI) applications. Our study reveals the expected influence of sensor location on signal quality and highlights the feasibility of single-sensor motor-imagery BCIs. We demonstrate OPM sensors' advantages over SQUID-based MEG and describe a preliminary version of the adaptive remnant filed compensation system to mitigate low frequency environmental magnetic noise.