Pavel Štarha

Pavel Štarha

Auto-generated profile, based on publicly available information

Pavel Štarha

Faculty of Mechanical Engineering, Brno University of Technology, Technicka 2, 616 69 Brno, Czechia

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2018 in The Astrophysical Journal
Verified
Journal Article
Closed access
BBBenjamin Boe
Benjamin Boe
SHShadia Habbal
Shadia Habbal
MDMiloslav Druckmüller
Miloslav Druckmüller
ELEnrico Landi
Enrico Landi
EKEhsan Kourkchi
Ehsan Kourkchi
JHJoseph Hutton
Joseph Hutton
Heavy ions are markers of the physical processes responsible for the density and temperature distribution throughout the fine-scale magnetic structures that define the shape of the solar corona. One of their properties, whose empirical determination has remained elusive, is the “freeze-in” distance (R f ) where they reach fixed ionization states that are adhered to during their expansion with the solar wind. We present the first empirical inference of R f for and derived from multi-wavelength imaging observations of the corresponding Fe xi ( ) 789.2 nm and Fe xiv ( ) 530.3 nm emission acquired during the 2015 March 20 total solar eclipse. We find that the two ions freeze-in at different heliocentric distances. In polar coronal holes (CHs) R f is around 1.45 R ⊙ for and below 1.25 R ⊙ for . Along open field lines in streamer regions, R f ranges from 1.4 to 2 R ⊙ for and from 1.5 to 2.2 R ⊙ for . These first empirical R f values: (1) reflect the differing plasma parameters between CHs and streamers and structures within them, including prominences and coronal mass ejections; (2) are well below the currently quoted values derived from empirical model studies; and (3) place doubt on the reliability of plasma diagnostics based on the assumption of ionization equilibrium beyond 1.2 R ⊙.

10 January 2020 in The Astrophysical Journal
Verified
Journal Article
Open access
BBBenjamin Boe
Benjamin Boe
SHShadia Habbal
Shadia Habbal
MDMiloslav Druckmüller
Miloslav Druckmüller
ADAdalbert Ding
Adalbert Ding
JHJana Hodérova
Jana Hodérova
PŠPavel Štarha
Pavel Štarha
We present the first remote sensing observations of the impact from a Coronal Mass Ejection (CME) on the thermodynamic properties of the solar corona between 1 and 3 R ⊙. Measurements of the Fe xi (789.2 nm) and Fe xiv (530.3 nm) emission were acquired with identical narrow-bandpass imagers at three observing sites during the 2017 August 21 Total Solar Eclipse (TSE). Additional continuum imagers were used to observe K+F corona scattering, which is critical for the diagnostics presented here. The total distance between sites along the path of totality was 1400 km, corresponding to a difference of 28 minutes between the times of totality at the first and last site. These observations were used to measure the Fe xi and Fe xiv emission relative to continuum scattering, as well as the relative abundance of Fe10+ and Fe13+ from the line ratio. The electron temperature (T e ) was then computed via theoretical ionization abundance values. We find that the range of T e is (1.1–1.2) × 106 K in coronal holes and (1.2–1.4) × 106 K in streamers. Statistically significant changes of T e occurred throughout much of the corona between the sites as a result of serendipitous CME activity prior to the eclipse. These results underscore the unique advantage of multi-site and multi-wavelength TSE observations for probing the dynamic and thermodynamic properties of the corona over an uninterrupted distance range from 1 to 3 R ⊙.

22 November 2022 in Journal of Apicultural Research
Verified
Journal Article
Open access
TNThi Quynh Nhu Nguyen
Thi Quynh Nhu Nguyen
MHMariana Hanková
Mariana Hanková
VKVojtěch Kružík
Vojtěch Kružík
AGAdéla Grégrová
Adéla Grégrová
TŠTereza Škorpilová
Tereza Škorpilová
HČHelena Čížková
Helena Čížková
In this study 12 acacia and 12 linden honey samples from the Czech Republic were analyzed with a chemometric and volatile compound profiles approach. The results of electrical conductivity (17.4 and 65.1 mS/m), free acidity (12.5 and 24.5 meq/kg), diastase activity (12.6 and 18.8 DN), colour (21.5 and 47.8 mm Pfund), hydroxymethylfurfural (HMF) (11.5 and 3.5 mg/kg), fructose (45.1 and 36.3 g/100g), fructose + glucose (F + G) (76.7 and 69.3 g/100g) content and fructose/glucose ratio (1.4 and 1.1) showed statistically significant differences (p < 0.05) between acacia and linden honey, respectively. The physico-chemical properties and pollen profiles were in compliance with the description of European monofloral honey, except for acacia honey due to the low proportion of acacia pollen (2.8 − 10.3%). According to volatile compounds analysis by head-space solid phase micro-extraction coupled with gas chromatography − mass spectrometry (HS-SPME/GC-MS), nine key volatile substances were selected from more than 100 volatile compounds present in the analysed samples for evaluation as markers of botanical origin typical of the most common plant nectar sources in the Czech Republic. Further, the non-targeted analysis combined with Principal Component Analysis (PCA) revealed trends and outliers within all chromatography data obtained for 24 honey samples. Cis-linalool oxide and β-linalool have been confirmed as markers of acacia honey, while carvacrol and p-cymenene were found almost exclusively in linden honey. The results demonstrated that the chemometrics with the non-targeted and targeted volatile compounds analysis approach is reliable and accurate for the classification of honey of various botanical origins.

2 April 2016 in Aerosol Science and Technology
Verified
Journal Article
Closed access
MBMiloslav Belka
Miloslav Belka
FLFrantisek Lizal
Frantisek Lizal
Jan JedelskyJan Jedelsky
Jan Jedelsky
PSPavel Starha
Pavel Starha
HDHana Druckmullerova
Hana Druckmullerova
MJMiroslav Jicha
Miroslav Jicha
Man-made vitreous fibers (MMVFs) are noncrystalline substances made of glass, rock or slag and are widely used as thermal or acoustic insulation materials. There is continued concern about their potential health impacts and thus, their dosimetry and behavior in the environment still require study using filters to collect fiber samples. After deposition or exposure measurements of MMVFs it is often necessary to analyze the filters with deposited fibers. This task is tedious, time-consuming, and requires skill. Therefore, many researchers have tried to simplify or automatize fiber detection and quantification. This article describes features of our in-house software, which automatically detects and counts fibers in images of filter samples. The image analysis is based on the use of a histogram equalization and an adaptive radial convolution filter that enhances fiber contrast and thus, improves the fiber identification. The accuracy of the software analysis was verified by comparison with manual counting using ordinary phase-contrast microscopy method. The correlation between the methods was very high (coefficient of determination was 0.977). However, there were some discrepancies caused by false identifications, which led to implementation of manual corrective functions. Copyright © 2016 American Association for Aerosol Research

27 July 2022 in The International Journal of Advanced Manufacturing Technology
Verified
Journal Article
Closed access
PDF file
JHJakub Hurník
Jakub Hurník
AZAneta Zatočilová
Aneta Zatočilová
TKTereza Konečná
Tereza Konečná
PŠPavel Štarha
Pavel Štarha
DKDaniel Koutny
Daniel Koutny

1 January 2006 in Acta Veterinaria Brno
Verified
Journal Article
Open access
PDF file
BTB. Tremlová
B. Tremlová
PŠP. Štarha
P. Štarha
František BuňkaFrantišek Buňka
František Buňka
ZGZ. Gistingrová
Z. Gistingrová
JHJ. Hrabě
J. Hrabě
Model cheese samples from 4 independent productions were heat sterilized (117 °C, 20 minutes) after the melting process and packing with an aim to prolong their durability. The objective of the study was to assess changes in the size and shape of fat globules due to heat sterilization by using image analysis methods. The study included a selection of suitable methods of preparation mounts, taking microphotographs and making overlays for automatic processing of photographs by image analyser, ascertaining parameters to determine the size and shape of fat globules and statistical analysis of results obtained. The results of the experiment suggest that changes in shape of fat globules due to heat sterilization are not unequivocal. We found that the size of fat globules was significantly increased ( p < 0.01) due to heat sterilization (117 °C, 20 min), and the shares of small fat globules (up to 500 μm 2 , or 100 μm 2 ) in the samples of heat sterilized processed cheese were decreased. The results imply that the image analysis method is very useful when assessing the effect of technological process on the quality of processed cheese quality.