Guangshen Ma

Guangshen Ma

Auto-generated profile, based on publicly available information

Guangshen Ma

University of Michigan

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 January 2025 in Biomedical Optics Express
Verified
Journal Article
Closed access
GMGuangshen Ma
Guangshen Ma
MMMorgan McCloud
Morgan McCloud
YTYuan Tian
Yuan Tian
ANAmit Narawane
Amit Narawane
HSHarvey Shi
Harvey Shi
MDMark Draelos
Mark Draelos
Optical coherence tomography (OCT) is an interferometric technique for micron-level imaging in biological and non-biological contexts. As a non-invasive, non-ionizing, and video-rate imaging modality, OCT is widely used in biomedical and clinical applications, especially ophthalmology, where it functions in many roles, including tissue mapping, disease diagnosis, and intrasurgical visualization. In recent years, the rapid growth of medical robotics has led to new applications for OCT, primarily for 3D free-space scanning, volumetric perception, and novel optical designs for specialized medical applications. This review paper surveys these recent developments at the intersection of OCT and robotics and organizes them by degree of integration and application, with a focus on biomedical and clinical topics. We conclude with perspectives on how these recent innovations may lead to further advances in imaging and medical technology.

21 July 2021 in IEEE Journal of Translational Engineering in Health and Medicine
Verified
Journal Article
Open access
MTMatthew Tucker
Matthew Tucker
GMGuangshen Ma
Guangshen Ma
WRWeston Ross
Weston Ross
Daniel BucklandDaniel Buckland
Daniel Buckland
PCPatrick J. Codd
Patrick J. Codd
Objective: Create a device that improves the identification and extent of resection at the interface between healthy and tumor tissue; ultimately, using this device would improve surgical outcomes for patients and increase survival. Methods: We have created a contactless tumor removal system that utilizes endogenous fluorescence feedback to inform a laser ablation system to execute autonomous removal of phantom tumor tissue. Results: This completely non-contact surgical system is capable of resecting the tumor boundary of a tissue phantom with an average root mean square error (RMSE) of approximately 1.55 mm and an average max error of approximately 2.15 mm. There is no difference in the performance of the system when changing the size of the internal tumor from 7.5-12.5 mm in diameter. Discussion: Future research steps include creating a more intelligent spectral search strategy to increase the density of points around the resection boundary, and to develop a more sophisticated classifier to predict pathologic diagnosis and tissue subtypes located regionally around the tumor boundaries. We envision this device being used to resect the boundaries of tumors identified by exogenously delivered tumor-labeling fluorophores, such as fluorescein or 5-ALA, in addition to approaches relying on autofluorescence of endogenous fluorophores.

30 October 2025 in Biomedical Optics Express
Verified
Journal Article
Closed access
XPXiaorui Peng
Xiaorui Peng
KKKyoungmo Koo
Kyoungmo Koo
GMGuangshen Ma
Guangshen Ma
MDMark Draelos
Mark Draelos
Xueding WangXueding Wang
Xueding Wang
Photoacoustic imaging (PAI) is a hybrid imaging modality that combines optical excitation with ultrasound (US) detection to achieve high-resolution, high-contrast imaging of biological tissues. As a non-ionizing and scalable imaging technique, PAI has been widely applied in biomedical research and clinical diagnostics, enabling functional and molecular imaging of a variety of medical conditions. In recent years, the rapid advancement of medical robotics has introduced new possibilities for PAI, particularly in the technologies of automated scanning, teleoperated robotics systems, and microrobots. This review surveys the latest developments at the intersection of PAI and robotics, categorizing them by integration level and application domain, with a primary focus on biomedical and clinical implementations. We conclude with perspectives on how these emerging technologies may drive future innovations in imaging, intervention, and healthcare robotics.

30 October 2025 in Biomedical Optics Express
Verified
Journal Article
Closed access
KKKyoungmo Koo
Kyoungmo Koo
XPXiaorui Peng
Xiaorui Peng
GMGuangshen Ma
Guangshen Ma
NANada Abdulaziz
Nada Abdulaziz
DMDavid Mills
David Mills
Xueding WangXueding Wang
Xueding Wang
Ultrasound (US) imaging is a standard clinical tool for assessment of soft tissue inflammation, particularly for imaging the peripheral joints of the hands and feet, which are usually the first to be affected by rheumatoid arthritis. Robotic US has recently gained attention as a means of delivering repeatable and operator-independent imaging. Previously developed robotic US for 3D volumetric imaging of human finger joints relies on the linear scan of the target joint to collect a series of 2D B-mode US images. Although effective in many contexts and simple in control and image reconstruction, the linear scan is suboptimal for imaging cylindrical tissue structures such as human fingers, often exhibiting degraded image quality in peripheral regions due to poor angular alignment with the tissue surface. To address this limitation, we developed a robotic US system incorporating an arc-shaped scanning trajectory designed to maintain a consistently perpendicular orientation to the curved surface of the finger throughout the scan. In an experiment on a spherical phantom, arc scan yielded improved boundary sharpness and image contrast compared to linear scan. In a clinical study involving both a healthy volunteer and an arthritis patient, the arc scan produced better B-mode US image quality in imaging finger joints compared to the linear scan, as reflected in more consistent representations of phalangeal and soft tissue structures along different radial directions. Functional Doppler US and photoacoustic (PA) imaging of finger joints were also conducted. Arc scan and linear scan achieved comparable detection of vascular signals. These findings demonstrate that arc scan facilitated by the robotic arm can achieve improved B-mode US imaging of tissue anatomy in human finger joints while preserving the functional imaging capability of Doppler US and PA imaging.

24 May 2021 in IEEE Journal of Translational Engineering in Health and Medicine
Verified
Journal Article
Open access
GMGuangshen Ma
Guangshen Ma
WRWeston Ross
Weston Ross
MTMatthew Tucker
Matthew Tucker
PHPo-Chun Hsu
Po-Chun Hsu
Daniel BucklandDaniel Buckland
Daniel Buckland
PCPatrick J. Codd
Patrick J. Codd
Viral and bacterial pathogens can be transmitted through direct contact with contaminated surfaces. Efficient decontamination of contaminated surfaces could lead to decreased disease transmission, if optimized methods for detecting contaminated surfaces can be developed. Here we describe such a method whereby thermal tracking technology is utilized to detect thermal signatures incurred by surfaces through direct contact. This is applicable in public places to assist with targeted sanitation and cleaning efforts to potentially reduce chance of disease transmission. In this study, we refer to the touched region of the surface as a “touch-point” and examine how the touch-point regions can be automatically localized with a computer vision pipeline of a thermal image sequence. The pipeline mainly comprises two components: a single-frame and a multi-frame analysis. The single-frame analysis consists of a Background subtraction method for image pre-processing and a U-net deep learning model for segmenting the touch-point regions. The multi-frame analysis performs a summation of the outputs from the single-frame analysis and creates a cumulative map of touch-points. Results show that the touch-point detection pipeline can achieve 75.0% precision and 81.5% F1-score for the testing experiments of predicting the touch-point regions. This preliminary study shows potential applications of preventing indirect pathogen spread in public spaces and improving the efficiency of cleaning sanitation.

2 May 2023 in arXiv
Verified
Preprint
Open access
PDF file
GMGuangshen Ma
Guangshen Ma
RPRavi Prakash
Ravi Prakash
BMBrian Mann
Brian Mann
WRWeston Ross
Weston Ross
PCPatrick Codd
Patrick Codd
In robotic laser surgery, shape prediction of an one-shot ablation cavity is an important problem for minimizing errant overcutting of healthy tissue during the course of pathological tissue resection and precise tumor removal. Since it is difficult to physically model the laser-tissue interaction due to the variety of optical tissue properties, complicated process of heat transfer, and uncertainty about the chemical reaction, we propose a 3D cavity prediction model based on an entirely data-driven method without any assumptions of laser settings and tissue properties. Based on the cavity prediction model, we formulate a novel robotic laser planning problem to determine the optimal laser incident configuration, which aims to create a cavity that aligns with the surface target (e.g. tumor, pathological tissue). To solve the one-shot ablation cavity prediction problem, we model the 3D geometric relation between the tissue surface and the laser energy profile as a non-linear regression problem that can be represented by a single-layer perceptron (SLP) network. The SLP network is encoded in a novel kinematic model to predict the shape of the post-ablation cavity with an arbitrary laser input. To estimate the SLP network parameters, we formulate a dataset of one-shot laser-phantom cavities reconstructed by the optical coherence tomography (OCT) B-scan images for the data-driven modelling. To verify the method. The learned cavity prediction model is applied to solve a simplified robotic laser planning problem modelled as a surface alignment error minimization problem. The initial results report (91.1 +- 3.0)% 3D-cavity-Intersection-over-Union (3D-cavity-IoU) for the 3D cavity prediction and an average of 97.9% success rate for the simulated surface alignment experiments.