Yuan Tian

Dr. Yuan Tian


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 January 2025 in Biomedical Optics Express
Verified
Journal Article
Closed access
GMGuangshen Ma
Guangshen Ma
MMMorgan McCloud
Morgan McCloud
YTYuan Tian
Yuan Tian
ANAmit Narawane
Amit Narawane
HSHarvey Shi
Harvey Shi
MDMark Draelos
Mark Draelos
Optical coherence tomography (OCT) is an interferometric technique for micron-level imaging in biological and non-biological contexts. As a non-invasive, non-ionizing, and video-rate imaging modality, OCT is widely used in biomedical and clinical applications, especially ophthalmology, where it functions in many roles, including tissue mapping, disease diagnosis, and intrasurgical visualization. In recent years, the rapid growth of medical robotics has led to new applications for OCT, primarily for 3D free-space scanning, volumetric perception, and novel optical designs for specialized medical applications. This review paper surveys these recent developments at the intersection of OCT and robotics and organizes them by degree of integration and application, with a focus on biomedical and clinical topics. We conclude with perspectives on how these recent innovations may lead to further advances in imaging and medical technology.

14 July 2015 in American Journal of Physical Anthropology
Verified
Journal Article
Closed access
PDF file
ATAndrea B. Taylor
Andrea B. Taylor
YTYuan Tian
Yuan Tian
CRCallum F. Ross
Callum F. Ross
CVChristopher J. Vinyard
Christopher J. Vinyard

5 January 2022 in IEEE Robotics and Automation Letters
Verified
Journal Article
Open access
WEWilliam Edwards
William Edwards
GTGao Tang
Gao Tang
YTYuan Tian
Yuan Tian
MDMark Draelos
Mark Draelos
JIJoseph Izatt
Joseph Izatt
KHKris Hauser
Kris Hauser
Deep anterior lamellar keratoplasty (DALK) is a technique for cornea transplantation which is associated with reduced patient morbidity. DALK has been explored as a potential application of robot microsurgery because the small scales, fine control requirements, and difficulty of visualization make it very challenging for human surgeons to perform. We address the problem of modelling the small scale interactions between the surgical tool and the cornea tissue to improve the accuracy of needle insertion, since accurate placement within 5% of target depth has been associated with more reliable clinical outcomes. We develop a data-driven autoregressive dynamic model of the tool-tissue interaction and a model predictive controller to guide robot needle insertion. In an ex vivo model, our controller significantly improves the accuracy of needle positioning by more than 40% compared to prior methods.

31 August 2022 in Biomedical Optics Express
Verified
Journal Article
Closed access
YTYuan Tian
Yuan Tian
MDMark Draelos
Mark Draelos
RMRyan P. McNabb
Ryan P. McNabb
KHKris Hauser
Kris Hauser
AKAnthony N. Kuo
Anthony N. Kuo
JIJoseph A. Izatt
Joseph A. Izatt
Optical coherence tomography (OCT) may be useful for guidance of ocular microsurgeries such as deep anterior lamellar keratoplasty (DALK), a form of corneal transplantation that requires delicate insertion of a needle into the stroma to approximately 90% of the corneal thickness. However, visualization of the true shape of the cornea and the surgical tool during surgery is impaired in raw OCT volumes due to both light refraction at the corneal boundaries, as well as geometrical optical path length distortion due to the group velocity of broadband OCT light in tissue. Therefore, uncorrected B-scans or volumes may not provide an accurate visualization suitable for reliable surgical guidance. In this article, we introduce a method to correct for both refraction and optical path length distortion in 3D in order to reconstruct corrected OCT B-scans in both natural corneas and corneas deformed by needle insertion. We delineate the separate roles of phase and group index in OCT image distortion correction, and introduce a method to estimate the phase index from the group index which is readily measured in samples. Using the measured group index and estimated phase index of human corneas at 1060 nm, we demonstrate quantitatively accurate geometric reconstructions of the true cornea and inserted needle shape during simulated DALK surgeries.

12 August 2025 in Sensors
Verified
Journal Article
Open access
PDF file
YWYizhu Wang, Wang
Yizhu Wang, Wang
XHXiaoming He
Xiaoming He
YTYuan Tian
Yuan Tian
CLChang Liu
Chang Liu
DWDepeng Wang
Depeng Wang
High-resolution and three-dimensional measurements at large scales represent a crucial frontier in flow diagnostics. Color-encoded illumination particle imaging velocimetry has emerged as a promising non-contact volumetric measurement technique in recent years. By employing chromatic gradient illumination to excite tracer particles, this method encodes depth information into color signatures, which are then correlated with two-dimensional positional data in images to reconstruct three-dimensional flow fields using a single camera. This review first introduces the fundamental principles of particle image velocimetry/particle tracking velocimetry and chromatic-depth encoding. Subsequently, we categorize color-depth-encoded particle velocimetry methods based on different illumination strategies, including LED-based, projector-based, and laser-based systems, discussing their respective configurations and representative applications. Finally, we summarize the current research progress in color-encoded particle image velocimetry techniques, provide a comparative analysis of their advantages and limitations, and discuss existing challenges along with future development prospects.

16 June 2023
Verified
Conference Paper
Closed access
XNXie Nihui
Xie Nihui
YTYuan Tian
Yuan Tian
ZYZhai Yunxuan
Zhai Yunxuan
GZGeng Zhenhua
Geng Zhenhua
LHLiu Huan
Liu Huan
To improve imaging quality of satellite camera in orbit, the blackbody temperature control system with the FPGA as the core is used. However, the system tends to take up plenty of the limited logic resources of the FPGA chip since it adopts a complex algorithm to control many blackbodies. To cope with such as problem, the paper adopts two approaches to optimize the utilization of logic resources. One is the software modular programming method that adopts a top-down approach to plan out the overall architecture of the software, which can increase code reuse and readability, thereby saving a lot of logic resources. While, the other one is the serial programming method that achieves the temperature control of multiple blackbodies by using only one logic cell of the FPGA chip, greatly increasing the utilization of logic resources. Through comparative study, the paper provides methods to optimize the utilization of FPGA resources and serve as a reference for other similar control systems.