Bruno Schwagten

Bruno Schwagten

Auto-generated profile, based on publicly available information

Bruno Schwagten

ZNA Middelheim Hospital , Antwerp , Belgium

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 January 2014 in EP Europace
Verified
Journal Article
Open access
PDF file
Yves De GreefYves De Greef
Yves De Greef
IBI. Buysschaert
I. Buysschaert
BSB. Schwagten
B. Schwagten
DSD. Stockman
D. Stockman
RTR. Tavernier
R. Tavernier
MDM. Duytschaever
M. Duytschaever
Pulmonary vein isolation (PVI) is an accepted treatment to relieve symptoms in patients with atrial fibrillation (AF). We studied 3 year outcome after PVI guided by duty-cycled multi-electrode radiofrequency (RF) ablation (pulmonary vein ablation catheter, PVAC) and provided comparative data to outcome after conventional PVI (CPVI) using mapping with irrigated, point-per-point RF ablation. One hundred and sixty-one consecutive patients with symptomatic paroxysmal or persistent AF and minimal heart disease underwent PVI (PVAC, n = 79 vs. CPVI, n = 82). Follow-up (with symptom-guided rhythm monitoring) was truncated at 3 years in all patients. Success was defined as freedom of documented arrhythmia after a single procedure and without antiarrhythmic drug treatment (ADT). Baseline characteristics did not differ between both groups. At 3 years follow-up, single-procedure success without ADT was comparable between PVAC and CPVI (65% vs. 55%, P = NS). The majority of recurrences occurred during the first year (PVAC 79% vs. CPVI 70%, P = NS). The annual rate of very late recurrence (i.e. beyond 1 year) was similar in both groups (10.5% vs. 15%, P = NS). At 3 years follow-up, outcome after PVAC-guided PVI is comparable to conventional isolation by irrigated point-by-point RF ablation. In both strategies, the majority of recurrences occurred in the first year of ablation.

Verified
Journal Article
Open access
PDF file
MTMaxime Tijskens
Maxime Tijskens
JAJuan Pablo Abugattas
Juan Pablo Abugattas
HTHendrik Thoen
Hendrik Thoen
ASAntanas Strazdas
Antanas Strazdas
BSBruno Schwagten
Bruno Schwagten
Yves De GreefYves De Greef
Yves De Greef
Background: Adding electroanatomical left atrial (LA) voltage mapping to cryoballoon ablation (CBA) improves validation of acute pulmonary vein isolation (PVI). Aims: To determine whether the addition of mapping can improve outcome and PVI durability. Methods: One-year outcome and PV reconnection (PVR) rate at first repeat ablation were studied in 400 AF patients in a propensity-matched analysis (age, AF type, CHA2DS2-VASc score) between Achieve catheter-guided CBA with additional EnSite LA voltage maps performed pre- and post-CBA (mapping group; N = 200) and CT- and Achieve catheter-guided CBA (control group; N = 200). Clinical success was defined as freedom of documented AF or atrial tachycardia (AT) > 30 s. PV reconnection patterns were characterized in repeat ablations. Results: At 1 year, 77 (19.25%) patients had recurrence of AF/AT, significantly lower than in the mapping group: 21 (10.5%) vs. 56 (28%), p < 0.001. Procedure time was shorter (72.2 ± 25.4 vs. 78.2 ± 29.3 min, p = 0.034) and radiation exposure lower (4465.0 ± 3454.6 Gy.cm2 vs. 5940.5 ± 4290.5 Gy.cm2, p = 0.037). Use of mapping was protective towards AF/AT recurrence (HR = 0.348; 95% CI 0.210–0.579; p < 0.001), independent of persistent AF type (HR = 1.723; 95% CI 1.034–2.872; p = 0.037), and LA diameter (HR = 1.055; 95% CI 1.015–1.096; p = 0.006). At repeat ablation (N = 90), persistent complete PVI was seen in 14/20 (70.0%) versus 23/70 (32.9%) in the mapping and conventional group, respectively (p = 0.03). Reconnection rate of the right inferior PV was lower with mapping (10.0% vs. 34,3%, p = 0.035). Conclusions: Adding electroanatomical LA voltage mapping to CBA improves 1-year clinical outcome and lowers both procedure time and radiation exposure. At repeat, use of mapping increases complete persistent PVI mainly by improving PVI durability of the RIPV.

28 May 2015 in Netherlands Heart Journal
Verified
Journal Article
Open access
PDF file
LRL. De Roeck
L. De Roeck
LRL. Riahi
L. Riahi
SWS. Wijchers
S. Wijchers
DSD. Stockman
D. Stockman
YGY. De Greef
Y. De Greef
BSB. Schwagten
B. Schwagten
Transseptal puncture is the most commonly used technique to perform electrophysiological procedures in the left atrium. This case report describes a pulmonary vein isolation in a patient with a paroxysmal atrial fibrillation, complicated by the presence of an oversized Amplatzer device (AGA Medical Corp., Golden Valley, MN). A retrograde approach using the magnetic navigation system (Niobe, Stereotaxis Inc., St Louis, USA) was performed, and showed to provide a feasible, safe and successful alternative for catheter ablation of cardiac arrhythmias in patients in whom the classic transseptal approach is impossible.

7 August 2011 in Pacing and Clinical Electrophysiology
Verified
Journal Article
Closed access
PDF file
BSBruno Schwagten
Bruno Schwagten
YGYves DE Greef
Yves DE Greef
WAWillem‐Jan Acou
Willem‐Jan Acou
DSDirk Stockman
Dirk Stockman

24 May 2024 in EP Europace
Verified
Journal Article
Open access
MTMaxime Tijskens
Maxime Tijskens
JAJ P Abugattas
J P Abugattas
MWM Wolf
M Wolf
BSB Schwagten
B Schwagten
Yves De GreefYves De Greef
Yves De Greef
Objectives: The addition of pre- and post-ablation electroanatomical mapping with the Achieve catheter and EnSite mapping system has shown to improve acute pulmonary vein isolation (PVI) rate of cryoballoon ablation (CBA). Recently, our group also demonstrated an improvement in 1-year outcome. Current study aimed to investigate the impact on PVI durability as seen during repeat ablation procedure. Methods: 400 patients were compared in a propensity-matched analysis between CT- and Achieve catheter guided CBA (Control group; N=200) and Achieve catheter guided CBA with additional EnSite voltage maps performed pre- and post-CBA (Mapping group; N=200). Matching parameters were age, AF type and CHADS-VASc score. In patients undergoing repeat procedure, PV status was evaluated using CARTO mapping system. Results: Baseline characteristics did not differ between both groups (Persistent AF: 47,5% vs. 46,5%, P=0,841; diagnosis-to-ablation time: 28,1±15,1 vs. 33,2±41,7months, P=0,107). The mapping group had a shorter follow-up time (25,6±7,2 vs. 50,3±3,3months, P<0,001). Repeat ablation was performed in 20 patients in the mapping group and 70 patients in the control group. At repeat, the proportion of patients with persistent complete PVI was higher in the mapping group (14/20(70.0%) vs 23/70(32,9%), P=0,030). Interestingly, less reconnections of the right inferior PV were seen in the mapping group (10,0% vs. 34,3%, P=0,035). There was no difference in reconnection rate of other PVs. Conclusions: The addition of electro-anatomical EnSite mapping to the Achieve catheter improves PVI durability as seen during repeat ablation, mainly at the level of the right inferior PV. This finding might explain the improvement in 1-year outcome of this approach.

1 March 2018 in EP Europace
Verified
Closed access
YGY De Greef
Y De Greef
ESE Stroker
E Stroker
BSB Schwagten
B Schwagten
JCJ De Cocker
J De Cocker
GCG B Chierchia
G B Chierchia
IBI Buysschaert
I Buysschaert
Background: To achieve a good clinical outcome often ≥1 ablation is needed. Each additional ablation exposes the patient again to all reported complications.